Getting to know your thermostat

THERMOSTAT QUICK REFERENCE

Getting to know your thermostat

2

Fan Button

3

System Button

4

Menu Buttons Access Door

5

Temperature Setpoint Buttons

6

Menu Button

7

User Program Buttons

8

Glow in the Dark Light Button

6

7

8

1

2

3

4

5

Important:

The low battery indicator is displayed 
when the AA battery power is low. If the 
user fails to replace the battery within 
21 days, the thermostat display will only 
show the low battery indicator as a final 
warning before the thermostat 
becomes inoperable. The batteries are 
located on the back of the thermostat.

LCD

1

Hold is displayed when

thermostat program is 

permanently overridden.

+1 will appear in the

display when second

stage of heat or cool

is on. +2 will appear

for third stage of heat.

System operation 

indicators:

 The 

COOL, 

HEAT

 or 

FAN

 icon will 

display when the 

COOL, 

HEAT

 or 

FAN 

is on.

NOTE: The compressor 

delay feature is active if 

these icons are flashing. 

The compressor will not 

turn on until the 5 minute 

delay has elapsed.

Days of the 

week and time

Low Battery Indicator:

 

Replace batteries when 

this indicator is shown.

Program Menu Options:

Shows different options

during programming.

Indicates the 

current room 

temperature.

Programmable 

Time Period Icons:

 

This thermostat has 

4 programmable time 

periods per day.

Displays the user 

selectable setpoint 

temperature.

Set Point Buttons
Program Buttons

Fan Button

Menu Button 

Glow in the Dark Light Button

6

1

2

3

4

5

All our thermostats use the same universal magnetic badge.

Visit our website to learn more about our free private label program.

About the Badge

LCD Display

Low Battery 

Indicator: 

Replace 

batteries 

when this 

indicator

is shown.

1

Removing the private label badge

Gently slide a screwdriver into the 

bottom edge of the badge. Gently 

turn the screwdriver counter 

clockwise. The badge is held on by a 

magnet. The badge should pry off 

easily. Do not use force. 

Magnet in door

Use the bevel on lower ridge

Getting to know your thermostat

Indicates the 

current room 

temperature.

Displays the user 

selectable setpoint 

temperature.

Hold is displayed when 

thermostat program is 

permanently overridden.

Days of the 

week and time

System Operation 

Indicators: 

If these or the 

Fan indicator are flashing, it 

means that they are in a 

delay of some type 

(Compressor Delay, Cooling 

Fan Delay, Staging Delay).

Program Menu Options:

Show different options 

during programming. 

Programmable Time Periods

Residential:

 uses 4 time 

periods- WAKE, RETURN, LEAVE 

and SLEEP.  

Commercial: 

uses 2 or 4 time 

periods that appear in the text 

field - Occupied and 

Unoccupied.

7

10

2

3

4-6

7

9

8

System Button

Button/Battery Access Door

88:88

AM

PM

8.8

C

F

S e t   A t

8.8

H O L D

HEAT ON

COOL ON

+1+2

Wake Return

Leave Sleep

SunMonTue

WedThurFriSat

Tech

Setup

Prev

SetHold

Sched

Next

SetHold

Run

Sched

Menu 

Done

IAQ

On

Auto

Em.Heat

AutoOn

Cool

The low battery indicator is displayed when 

the AA battery power is low.  If the user fails to 

replace the battery within 21 days, the screen 

will only show the low battery indicator but 

maintain all functionality.  If the user fails to 

replace the batteries after an additional 21 

days (days 22-42 since first “low battery” 

display) the set points will change to 

55˚F(Heating) and 85˚F(Cooling).  If the user 

adjusts these setpoints away from these it will 

hold for 4 hours then return to either 55˚F or 

85˚F.  After day 42 the batteries must be 

replaced immediately to avoid freezing or 

overheating because the thermostat will shut 

the unit off until the battery is changed. 

Important

8

9

11

5:23

PM

F

Tue

Menu

Auto

Off

10

Battery Cover

11

Staging Indicators 

+1 will apear in the

display when second

stage of heat or cool is on.

+2 will appear for third

stage of heat.

Содержание S-855C Series

Страница 1: ...ttery Power Hardwire Common Wire Hardwire Common Wire with Battery Backup Power Type 1 Specifications Rev 1413 A trained experienced technician must install this product Carefully read these instructi...

Страница 2: ...there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Pick an installation location that is easy for the user to access The temperature of the loca...

Страница 3: ...the bottom edge of the badge Gently turn the screwdriver counter clockwise The badge is held on by a magnet The badge should pry off easily Do not use force Magnet in door Use the bevel on lower ridge...

Страница 4: ...disconnect the power before beginning to install this product can cause electric shock or equipment damage Caution Mercury Notice Vertical Mount Horizontal Mount Vertical Mount Horizontal Mount 4 SUBB...

Страница 5: ...Typical 2H 2C system 1 transformer Typical 2H 2C system 2 transformer COMPRESSOR RELAY FAN RELAY HEAT RELAY 4 2 1 C R L2 L1 HOT C R L2 L1 HOT REMOVE JUMPER Typical heat only system HEAT RELAY 4 2 1 C...

Страница 6: ...l System 2 Heat 2 Cool Heat Pump System 3 Heat 2 Cool Heat Pump System RC RH C B O G W E Y Y2 W2 Transformer Power cooling Transformer Power heating Transformer common Energized in heating Energized i...

Страница 7: ...ompressor delay of 5 minutes when the thermostat detects a power outage from the hardwired power supply Important High quality alkaline batteries are recommended Rechargeable batteries or low quality...

Страница 8: ...r example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint The cooling swing setting is ad...

Страница 9: ...lock setting 12 Hour Clock Morning Recovery This feature will start heating early to bring the building temperature to its programmed setpoint by the beginning of the time period WAKE OCCUPIED Use the...

Страница 10: ...ption will turn the heat pump off 45 seconds after the auxiliary heat relay turns on For 2 heat applications the first stage will turn off 45 seconds after the auxiliary stage turns on For 3 heat appl...

Страница 11: ...to select OFF 1YEAR 2YEAR IAQ Cell Reminder Will remind the user to change the PHI Cell after 25 000 hrs Use the or key to select OFF 250 Stands for 25000 hours IAQ Mode Cycle This feature will confi...

Страница 12: ...rent hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6...

Страница 13: ...n OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Wake OCC 1 Leave UNOCC 1 Return OCC 2 Sleep UNOCC 2 Occupied Unoccupied Occupied Unocc...

Страница 14: ...me period and for Saturday SLEEP UNOCC2 time period Repeat steps 4 through 7 for Sunday WAKE OCC1 time period for Saturday LEAVE UNOCC1 time period for Sunday RETURN OCC2 time period and for Saturday...

Страница 15: ...PROGRAMMING 15 If you want to use IAQ mode during this time period select IAQ with the fan key Sunday time If you want to use IAQ mode during this time period select IAQ with the fan key...

Страница 16: ...riod begins Your program setpoint will then replace your temporary setpoint Permanent hold If you press the HOLD key at the bottom of your screen you will see HOLD appear below the setpoint temperatur...

Отзывы: