Motor
Motor Support
Axial Flow Fan
Nut
6. Disassemble the axial flow fan
Unscrew the nut fixing the fan with a spanner to
take out the fan.
7. Disassemble Motor
Unscrew the screws fixing the motor support ,
and then lift it upwards to remove it. Unscrew the
screws fixing the motor to remove it.
Weld
Four-way valve
coil
8. Disassemble Four-way Valve
Wrap the four-way valve with wet cotton and
unsolder the 4 weld connecting the four-way valve
to take it out.
Note: Refrigerant should be discharged firstly.
Welding process should be as quick as possible
and keep wrapping cotton wet all the time. Be
sure not to burn out the lead-out wire of
compressor.