Page 20 of 47
5
Receiver Functions and Operations
Press the “Return” pushbutton to select or deselect a function as indicated by a dot. To exit the user menu,
press “i” pushbutton.
Broad Peak Mode:
Increased sensitivity but sharpness
reduced. Useful for deep pipes.
Peak with Arrows Mode:
Largest signal over the pipe. Includes left/
right guidance arrows.
Null Mode:
Minimum signal over the
pipe includes left/right
guidance arrows.
Sonde Mode:
Largest signal over the Sonde. Note:
Locator is held ACROSS the line of the
Sonde. Also note two false signals each
side of main signal.