Page 45 of 47
C. Operational
Item
Information
displayed
Parameter
• Output Frequency
• Output Current setting
• Output Current
• Output Voltage (info menu)
• Operating Temperature (info menu)
Signal Application
Modes
Transmitting
Frequencies
(varies by country
& market)
Transmitting Mode
Power output
Output voltage
Output current
Controls
Compatible with
Receiver
•
Direct connection mode only-
applies signal directly to the cable by clipping one
output lead to the pipe, the other to an independent ground or anode bed.
• 98Hz, 128Hz, 512Hz, 640Hz, 3Hz/98Hz, 3Hz/128Hz, 4Hz/98Hz
• 4Hz/128Hz, ELF1-3Hz/6Hz/98Hz;
• ELF2-3Hz/6Hz/128Hz
• ELF3-4Hz/8Hz/98Hz; ELF4-4Hz/8Hz/128Hz;
• 3Hz/6Hz/512Hz;
• 3Hz/6Hz/640Hz;
• 4Hz/8Hz/512Hz;
• 4Hz/8Hz/640Hz
Other multiple frequencies in the range of 3Hz to 2 kHz available upon request.
Powered by AC: 150W
Powered by DC: 12-20V, 50W
Maximum output voltage = 120V RMS
Maximum output current = 4A RMS with up to 2 frequencies. Output limited
to 3A with three or four simultaneous frequencies.
Uses 2 Rotary/Push control knobs to select:
• Frequency
• Output level
• Information
• ACTIVE/STANDBY pushbutton
• One On/OFF pushbutton
vLocDM
10
Data Sheet
Item
Temperature Range
Parameter
Operating : -4ºF to122 ºF
(-20ºC to 50ºC)
Storage : -40ºF to 140ºF
(-40ºC to 60ºC)
D. Environmental
Weather Proof
IP54 and NEMA 4
Warranty
Parameter
12 months
E. Warranty
Item
Shipping Weight
44.1lbs
(20kg)
Shipping Dimension
21.7”(L) x 15.2”(W) x 18.3”(H)
(550(L) x 385(W) x 465(H) mm)