6.6.1 Fault Finding Method
1. Connect the transmitter as previously described. Select either 3Hz/6Hz/98Hz (ELF1) or 3Hz/6Hz/
128Hz (ELF2) depending on mains frequency as previously described.
2. Connect the A-frame as above.
6.6.2 Using the A-frame
If the position of a defect has been identified by the vLocDM using the current gradient technique, start an
A-frame survey approximately 20 meters before this point. Place the A-frame in the ground with the A-frame in
line, the green pin pointing towards the suspected fault and directly above the pipe. The signal strength will be
displayed, if the signal is strong enough an arrow will point forward and press the “+” pushbutton to save the
reading. This will enter the result into the graph. Pressing the “-” pushbutton will delete the last record.
The searching of the graph is automated and may change as points are added.
A-frame
Defect
128Hz
15dB
1
2
3
4
A-frame Screen
1 Locate Icon
2 Fault Direction
3 Fault Signal
4 Graph