![Vitek VT-NV1600P Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/vitek/vt-nv1600p/vt-nv1600p_user-manual_1035418050.webp)
VT-NV Series – On Cue IP
49
6.5.2 ALARM OUTPUT SETUP
Configure activation of Relay output.
ALARM OUT : Select Relay for the operation to be configure
4ch NVR : 1 relay , 8/16ch NVR: 2 relays
OPERATION: Configure output status of Relay.
!
DISABLE: Relay is not working
!
ENABLE: Relay is working once event is triggered.
MODE: Configure activation of Relay output.
!
TRANSPARENT: Keep Relay output until event trigger has stopped.
!
LATCHED: Keep relay output for duration time from the event last triggered.
DURATION: If the alarm output mode is configured as Latched. Configure duration time
for relay output.
TYPE : Define the transition of the signal of Alarm output
!
N/O (Active Low): When event is triggered, the relay will go to ‘Closed’ state from
‘Open’.
!
N/C(Active High): When event is triggered, the relay will go to ‘Open’ state from
‘Closed’
HDD EVENT: Select “ON”, when HDD related Event is triggered, relay output will be
triggered.
SENSOR: When sensor input is triggered, relay output will be triggered.
VIDEO LOSS: When video loss occurs, relay output will be triggered.
MOTION: When motion is triggered, replay output will be triggered.