14
3.
Type the password (the default password is
"1qaz!QAZ"
) and click the blue arrow. The
MGW Diamond web interface is loaded.
Initial Connection and IP Setup
The MGW Diamond Encoder is configured, by default, to use a fixed static IP address for its
Ethernet Port 1 Use the default
192.168.1.1
IP address to perform initial login from a computer
connected directly to the platform.
Ethernet Port 2 is by default configured in DHCP mode.
To configure the appliance's network settings for the first time from a web browser:
1.
Connect a power source to the rear power input port.
2.
Connect the network port labeled "Ethernet 1" to a computer in the
192.168.1.x
range
with subnet
255.255.255.0
and ensure you can ping the default IP address of the unit to
192.168.1.1.
3.
Either use an Internet browser or open an SSH terminal.
To configure the appliance's network settings for the first time through the browser:
1.
Type the appliance's IP address in the URL field. The login window appears.
Figure 3-2: MGW Diamond Login window