11
2.6 CONNECTIONS
• Connecting to the RS485/ 422
The dome camera can be controlled remotely by an external device or control system,
such as a control keyboard, using RS485 half-duplex, RS422 full duplex or simplex serial communications
signals.
For RS485 connect the ports marked Tx+, Tx- to Tx+(Rx+) and Tx-(Rx-)
If control system is RS422, connect Rx+(Tx+), Rx+(Tx-) and Rx+, Rx- of the dome camera to Rx+, Rx-
and Tx+, Tx- of the control device respectively.
•
Connecting Video out connector
Connect the video out(BNC) connector to the monitor or video input.
• Connecting Alarms
AL1 to 8 (Alarm In)
You can use external devices to signal the dome camera to react on events. Mechanical or electrical
switches can be wired to the AL (Alarm In) and GND (Ground) connectors.. See Chapter 3
— Program
and Operation for configuring alarm input.
GND (Ground)
NOTE: All the connectors marked GND are common.
Connect the ground side of the Alarm input and/or alarm output to the GND connector.
NC(NO)1 TO 4 (Normal Close or Normal Open : Alarm Out)
The dome camera can activate external devices such as buzzers or lights. Connect the device to the
NC(NO) (Alarm Out) and COM (Common) connectors. See Chapter 3
— Program and Operation for
configuring alarm output.
• Connecting the Power
Connect the power of AC 24V 850mA to the dome camera.
Use certified / Listed Class 2 power supply transformer only.
Note: If the dome is being mounted in and External housing an AC 24V 3A supply will be required, such
as the VPSU-243EXT.