PowerDome Installation Manual 

Introduction 

 

 

 

The 24VAC cable powers the PowerDome and the camera. To determine cable size, refer to the 
Power Cable Size and Length subsection of the Introduction. 

 

The RS485 control cable carries commands from the keypad to the PowerDome. An RS485 
compatible shielded, two-conductor, twisted-pair cable is required. Recommended cable size is 22 
gauge (0.64 mm). 

Note:

 When using the UTP interface modules Vista recommends that you use only active receivers. 

For UTC control, only a video coaxial cable is required. 

1.4 P

OWER 

R

EQUIREMENTS

 

 

CAUTION:

 

For optimal video performance, all PowerDomes must be powered from an isolated 24 VAC power 
source—fused outputs are not adequate. Allowable voltage range is 20 to 28 V. 

All domes require a 24 VAC power supply that provides isolated outputs to operate the domes’ pan/tilt 
drive, camera, and heater/fan (if applicable). The total power requirement varies depending on the model 
of the PowerDome.  

Dome power requirements (at 24 VAC): 

 

All domes without a heater/fan require 20 VA 

 

7 inch domes with heater/fan require 55 VA 

1.5 P

OWER 

C

ABLE 

S

IZE AND 

L

ENGTH

 

It is important to choose the proper gauge of the cable that supplies 24 V to the PowerDome. An 
inadequate gauge will cause a voltage drop resulting in improper operation.  

Table 1 gives the recommended cable lengths of varying wire gauges for a PowerDome with a colour 
camera. Note that the heater and fan reduces maximum cable length substantially. 
 

Table 1.  Maximum power cable lengths 

 

Wire Gauge 

All Domes 

without Heater/Fan

(20 VA) 

7 inch Domes 

with Heater/Fan 

(55 VA) 

(AWG) 

(mm

2

Feet 

Meters 

Feet 

Meters 

10 2.60 

1443 

440 

525 160 

12 

2.05 

906 

276 

329 

100 

14  1.62 569 173 207 63 

16 

1.29 

358 

109 

130 

40 

18 1.02 

225 69 82 25 

20 

0.81 

142 

43 

52 

16 

22 0.64 

89 27 32 10 

1040647A / July 2003 

Содержание PowerDome Series

Страница 1: ...PowerDome Series Installation Manual...

Страница 2: ...6 EEC the Low Voltage Directive LVD 73 23 the CE Marking Directive 93 68 EEC and all associated amendments This document is intended to provide accurate information however the information contained h...

Страница 3: ...2 2 2 Using the VPD EWM Wall Mount Bracket 20 2 2 2 1 Creating a Conduit Hole 23 2 2 3 Using the VPD ESM Swing Arm Mount 24 3 PTZ AND DOME INSTALLATION 29 3 1 RS485 TERMINATION 29 3 2 INSTALLING THE...

Страница 4: ...Before You Begin PowerDome Installation Manual APPENDIX D POWER SUPPLIES 41 VPD PSU2 OUTDOOR POWER SUPPLY 41 APPENDIX E MIRRORED DOME HANDLING 43 4 1040647A July 2003...

Страница 5: ...hooting this product refer to this document and any other documentation provided If you still have questions please contact Vista Technical Support and Sales 44 118 944 0123 Norbain House Eskdale Road...

Страница 6: ...e for coaxial UTC control The dome automatically detects the current protocol UTC control requires a Vista Triplex Columbus hard disk recorder and a minimum of one keyboard See Figure 1 A minimum of o...

Страница 7: ...ated outputs to operate the domes pan tilt drive camera and heater fan if applicable The total power requirement varies depending on the model of the PowerDome Dome power requirements at 24 VAC All do...

Страница 8: ...you send video via coaxial cable make the connections to a coaxial interface module When you send video via unshielded twisted pair UTP cable make connections to a UTP interface module Note Vista rec...

Страница 9: ...s sufficient clearance for the unit See Figure 5 Top of ceiling cavity 15 88 cm 6 25 in minimum clearance False ceiling Figure 5 False ceiling clearance The VPD T600 is a T bar support kit for mountin...

Страница 10: ...screws provided Ceiling ring mounting holes Figure 6 Installing the T bar support kit with ceiling ring 1 Remove the appropriate ceiling panel 2 Hold the ceiling ring in the desired location on the t...

Страница 11: ...of the panel Align the mounting holes with the drilled holes in the panel 2 Place the ceiling ring on the T bar brackets with its smooth side down and its mounting holes aligned with the mounting hole...

Страница 12: ...afety cable to the ceiling s superstructure and feed it through the mounting hole 2 Attach the housing to the safety cable To make cable connections and complete the housing installation perform the f...

Страница 13: ...ntrol signal in RS485 control signal out if used Video Data in or A 24 VAC Data in or B RJ45 Video out Video out 24 VAC A 24 VAC B RJ45 Figure 10 Coaxial interface module Figure 11 UTP interface modul...

Страница 14: ...VPD WM Wall Mount directly to a vertical surface Note Cables will usually come out of the mounting surface and enter the unit through the rear opening in the base If the cables are attached externally...

Страница 15: ...5 If necessary drill a pass through hole in the mounting surface for cable entry 6 Pull the video 24 VAC and RS485 cables from inside the mounting surface through the cable entry hole To mount the uni...

Страница 16: ...17 VPD WM UTP Interface Module VPD WM Coaxial Interface Module Cable s from VPD WM Cable s from VPD WM 24 VAC Coaxial video 24 VAC Twisted pair video out 24 VAC Twisted pair video out 24 VAC RS485 dat...

Страница 17: ...de the VPD WM Wall Mount Do not remove the safety cable after housing is installed To attach the housing safety cable to the mount safety clip see Figure 20 and perform the following 1 Slide a section...

Страница 18: ...See Figure 21 2 Connect the heater fan power cable to the 2 pin Molex connector on the VPD WM interface module See Figure 21 3 Guide the flange of the housing into the collar of the VPD WM and fasten...

Страница 19: ...onduit hole 1 Align the provided template with the side of the unit 2 Mark the center of the template s drill hole CAUTION To maintain material integrity do not drill the conduit hole Start with a pil...

Страница 20: ...1 1 to open a side entry conduit hole in the unit Note The factory secures the end of the safety chain with a quick tie to the dome opening as shown in Figure 25 To keep the safety chain from slippin...

Страница 21: ...ll with the appropriate fasteners Seal all mounting holes so that no moisture can leak into the mounting surface Mounting fasteners 4 Cables Minimum 16 kg 35 lb Figure 28 Mounting the unit Figure 29 L...

Страница 22: ...rDome Note There are two versions of the PowerDome interface module depending on whether video is being sent via coaxial cable PowerDome Coaxial Interface Module or unshielded twisted pair UTP wire Po...

Страница 23: ...oaxial interface module Figure 33 UTP interface module 5 Push the cables and interface module back into the cable access opening 6 Reinstall the cable access opening cover 7 To install the optional he...

Страница 24: ...llowing procedures Dome screws Mounting socket Junction box screw Collar Mounting plate Gasket UTP interface module Pem nut Junction box cover Coaxial interface module Junction box Junction box cover...

Страница 25: ...teners used Note Mounting fasteners are not included CAUTION For safety the hardware and procedure used for securing the top plate must enable it to support a minimum of a 16 kg 35 lb load See Figure...

Страница 26: ...ions perform the following 1 Place the sealing gasket on the inside of the junction box cover and then make the cable assembly connections to the terminal strip See Figure 41 2 WITH POWER OFF make the...

Страница 27: ...he swing arm and insert the PowerDome s interconnect cable into the RJ45 jack on the interface module See Figure 42 or Figure 43 6 Connect the heater fan power cable to the 2 pin Molex connector on th...

Страница 28: ...llar of the swing arm matching up the mating holes and fasten the housing to the swing arm using the three 10 32x3 8 screws provided See Figure 44 2 To install the optional heater fan assembly see App...

Страница 29: ...oop out to another unit i e it is the final receiver location or you are connecting a VPD ALM16 alarm module to a UTC controlled dome place the switch in the ON position 3 Apply 24 VAC power to the ho...

Страница 30: ...n completing the next step the PowerDome will move become active in both the pan and tilt directions as part of its orientation protocol 2 Push the spring latch handle outward while pivoting the pan t...

Страница 31: ...ome with coaxial UTC telemetry we recommend that you set the address especially if you plan to add a VPD ALM16 alarm module If you use RS485 directly from a Vista NPX KBD J3De or VPD KBD keyboard that...

Страница 32: ...ndant mount housing Safety clip Safety cable Mounting clips Flush mount housing Safety clips Safety cable Mounting clips Figure 48 Attaching the dome assembly to the upper housing CAUTION Do not touch...

Страница 33: ...come equipped with a variety of camera options and each camera s programming varies depending on available functions Refer to the PowerDome Programming Instructions manual for programming instruction...

Страница 34: ...ssembly with the appropriate mounting screw and lock washer 2 Insert the safety catch though the channel in the retaining bracket attached to the upper housing 3 Push the spring latch handle outward w...

Страница 35: ...ach various wall mount brackets or an outdoor power supply to a pole The adapter can be bolted to a pole or secured with three adjustable stainless steel bands CAUTION For safety the hardware and proc...

Страница 36: ...the pass through hole in the pole 3 Secure the adapter to the pole by tightening the barrel screw on each of the three stainless steel bands not provided See Figure 54 Note The bands used must ensure...

Страница 37: ...apter on the edge of the roof or parapet and mark the location of the mounting slots 4 Prepare the mounting slots in accordance with the type of wall concrete wood etc and fasteners used CAUTION For s...

Страница 38: ...e wall mount to the roof mount adapter 9 Attach the pendant mount housing to the VPD EWM according to section 2 2 2 Using the VPD EWM Wall Mount Bracket 10 Close the VPD ERM Roof Mount Adapter and sec...

Страница 39: ...e excessive and affect the operation of the PowerDome To install the fan onto the PowerDome pan tilt mechanism see Figure 58 and perform the following Screw slots Side PC card connector Fan assembly F...

Страница 40: ...ble switch value from that difference Continue to subtract the highest possible switch value from the difference until you have zero For example if you want address 53 Switch Address 53 Switch Value D...

Страница 41: ...VPD EPMA Pole Mount Bracket Fasteners are provided for all applications 1 Loosen the four watertight screws and remove the cover See Figure 59 2 To attach the unit directly to a wall mark the location...

Страница 42: ...ation Manual Live Brown Neutral Blue Power in Earth Y G Red 24 VAC out Red Figure 62 VPD PSU2 cable connections Note In case of a fuse failure always replace an IRT with a fuse of the same type and va...

Страница 43: ...eavier contaminants that cannot be removed with pressurized air Rinse the dome with water and immediately dry it with clean dry pressurized air to prevent water spots Avoid wiping the coated surface i...

Страница 44: ......

Отзывы: