D-302980 

Current Drain:

 Approx. 70 mA standby, 1600 mA peak at 

full load.  

Minimum battery voltage:

 4.8V 

Note:

 For CE compliance the battery backup period shall 

exceed 12 hours. 

Backup Battery Pack: 

4.8V 1300 mAh, rechargeable 

NiMH battery pack, p/n GP130AAM4YMX, manufactured 

by GP or equivalent.

 

Note:

 For compliance with UL standards the battery 

backup period shall exceed 24 hours. 

Backup Battery Pack: 

4.8V 2200 mAh, rechargeable 

NiMH battery pack, p/n GP230AAHC4YMX, manufactured 

by GP.

 

Battery Test:

 Once every 10 seconds. 

2.4 Communication  

Built-in Modem:

 300 baud, Bell 103 protocol 

Data Transfer to Local Computer: 

Via RS232 serial port

  

Report Destinations: 

2 central stations, 4 private telephones. 

Reporting Format Options: 

SIA, Pulse 4/2 1900/1400 Hz, 

Pulse 4/2 1800/2300 Hz, Contact ID, Scancom. 

Pulse Rate: 

10, 20, 33 and 40 pps - programmable

 

Message to Private Phones: 

Tone  

Ring Detection: 

The unit does not support ring detection 

without DC voltage present on the telephone lines. 

2.5 Physical Properties 

Operating Temp. Range:

 14°F to 120°F (-10°C to 49°C) 

Storage Temp. Range:

 -4°F to 140°F (-20°C to 60°C) 

Humidity:

 85% relative humidity, @ 30°C (86°F) 

Size:

 193 x 178 x 50 mm (7-5/8 x 7 x 2 in.) 

Weight:

 658g (23 Oz) (with battery)  

Color:

 White 

  

3. INSTALLATION

Note:

 This system must be checked by a qualified 

technician at least once every three (3) years. 

This equipment is designed to be connected to the telephone 
network using RJ11 connector which complies with Part 68 
rules and requirements adopted by ACTA and properly 
installed RJ31X connector. See drawing below for details.

 

In the case that RJ31X is not available (consult your 
telephone company or a qualified installer), the telephone 
line should be connected to the PowerMaxExpress unit 
first and then all other home equipment should be 
connected to PowerMaxExpress "Phone" outlet. 

Note: 

The REN is used to determine the number of 

devices that may be connected to a telephone line. 
Excessive RENs on a telephone line may result in the 
devices not ringing in response to an incoming call. In 
most but not all areas, the sum of RENs should not 
exceed five (5.0). To be certain of the number of devices 
that may be connected to a line, as determined by the 
total RENs, contact the local telephone company. The 
REN of alarm system is part of the product identifier that 
has the format US:VSOAL03BPMEXPRESS.

 

Connection to telephone company provided coin service is 
prohibited. Connection to party lines service is subject to 
state tariffs.

3.1 Unpacking the Equipment 

Open the cardboard packing box and check whether all 

items have been included. If you find out that an item is 

missing, contact your vendor or dealer immediately. 

3.2 Supplying Power to the Unit 

Connect power to the PowerMaxExpress temporarily (see 

figure 3.8). Alternatively, you may power up from the 

backup battery, as shown in figure 3.3. 

Disregard any “trouble” indications pertaining to lack of 

battery or lack of telephone line connection.  

For Europe Safety Compliance: 

a. The model shall be installed according to the local 

electrical code. 

b. The circuit breaker shall be readily accessible. 

c.  The rating of the external circuit breaker shall be 16A 

or less. 

d.  The cables for the AC mains connection shall have an 

overall diameter of 13mm and 16mm conduit. 

Please refer to Figure 3.6 "Power Cable Connection".

 

3.3 System Planning & Programming  

It pays to plan ahead - use the tables in appendices A and 

B at the end of this guide to register the intended location 

of each detector, the holder and assignment of each 

transmitter.  

Gather up all transmitters and detectors used in the 

system and mark each one in accordance with your 

deployment plan. 

Program the system now as instructed in the 

programming section.  

Содержание POWERMAXEXPRESS -

Страница 1: ...uble Beeps 13 4 4 12 Panic Alarm 13 4 4 13 Swinger Stop 13 4 4 14 Cross Zoning 13 4 4 15 Supervision 13 4 4 16 NOT READY 13 4 4 17 AUX Button A 13 4 4 18 AUX Button B 2 W KF 14 4 4 19 Jam Detect 14 4 4 20 Latchkey 14 4 4 21 Not Active 14 4 4 22 Back Light Optional 14 4 4 23 Duress 14 4 4 24 Piezo Siren 14 4 4 25 Reset Option 14 4 4 26 Tamper Option 14 4 4 27 Siren On Line 14 4 4 28 Memory Prompt 1...

Страница 2: ...obtained for the particular application Compatible detectors and transmitters are listed and described briefly in Appendix D Remember it is advisable to power up the control panel temporarily after unpacking and program it on the work bench in accordance with the installation plan The programming flow charts in the programming section show all options available for each parameter Factory defaults ...

Страница 3: ...Alarm inhibited during a single arming period swinger stop after 1 2 3 alarm tamper fault or not inhibited programmable selectable Note To comply with EN requirements the swinger stop should be set to 3 Alarm Types Silent alarm siren alarm future option or sounder internal alarm in accordance with zone attributes Siren Signals Continuous intrusion 24 hours panic triple pulse pause triple pulse fir...

Страница 4: ...me equipment should be connected to PowerMaxExpress Phone outlet Note The REN is used to determine the number of devices that may be connected to a telephone line Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to...

Страница 5: ...g is shown in figure 3 2 4 Drill 4 holes and insert wall anchors Back unit Mark 4 drilling points on mounting surface 3 Fasten the back unit with 4 screws 5 1 Release screws Remove front cover Figure 3 1 Back Unit Mounting CABLES ROUTING GUIDE Cables entry possibilities 1 Remove the left or right side cables entry knockout s and enter the required cable s Cable clips Remove and use as cable clamp ...

Страница 6: ... GREEN RED Relay PGM output Vmax 30v Imax 100mA External power supply 5 30VDC PGM ZONE WIRING Device 2 2 kΩ Tamper Alarm Note Do not use mains cable other than that supplied by the manufacturer 3 m long Figure 3 2 Wiring WARNING When plugging SIREN ZONE terminals back into place be sure to align them carefully with the pins on the PCB Misaligned or reverse insertion of terminals may damage interna...

Страница 7: ...y AC power or battery 4 Slide SIM card into cover 5 Rotate cover to close 1 Slide top cover Figure 3 5 SIM Card insertion 3 8 Power Cable Connection External power connections Option Connect the power cable and close the control panel as shown below Electrical socket outlet shall be installed near the equipment and shall be easily accessible WARNING DO NOT USE AN OUTLET CONTROLLED BY A WALL SWITCH...

Страница 8: ...ve or rejection 4 1 2 Entering an Invalid Installer Code If you enter an invalid installer code 5 times the keypad will be automatically disabled for 90 seconds and the message WRONG PASSWORD will be displayed 4 1 3 Installer s Menu The installer s menu is shown in figure 4 1a The text in rectangles represents the current PowerMaxExpress display 4 1 4 Setting a New Installer Code To set an install...

Страница 9: ...ether to enroll a wireless device by normal transmission or by device Tamper function opening its cover Options normal or by tamper 4 2 3 Enroll Delete Sensors Wired detector can be enrolled in zone 29 and wireless detectors can be enrolled in zones 01 28 STOP Before enrolling the lens at the front of PIR and dual technology sensors should be masked to prevent inadvertent transmission Make sure th...

Страница 10: ...ess siren self test button until a squawk is heard 1 sec approx TRANSMIT NOW Enrolling a wireless siren siren No 2 for next enrolling action AWAY 2way kp No 2 Deleting a wireless keypad MKP 150 151 Press MKP 150 151 back tamper switch once see MKP 150 151 inst instructions 2way kp No 2 OFF TO DELETE Deleting a wireless siren siren No 2 Open WL siren cover and remove its battery 1way kp No 5 Enroll...

Страница 11: ...lay Zxx CHIME Melody chime Chime off Zxx PARTITION see note Zxx KEY ON OFF z key enable z key disable OPTIONAL WALK TEST READY First display If Non alarm is selected Z05 P1 P2 P3 Attic Back door Basement Bathroom Bedroom Child room Closet UK Conservatory Den UK Playroom Selectable Zone Names Dining room Downstairs Emergency Fire Front door Garage Garage door Guest room Hall Kitchen Laundry room Li...

Страница 12: ... must not exceed 15 sec 4 4 3 Exit Delay Fig 4 4 location 03 An exit delay allows the user to arm the system and leave the protected site via specific routes and doors without causing an alarm Slow rate warning beeps start sounding once the arming command has been given until the last 10 seconds of the delay during which the beeping rate increases Location No 3 allows programming of the exit delay...

Страница 13: ...n 12 Here you determine whether the user will be allowed to initiate a panic alarm by simultaneous pressing either the two panic buttons on the keypad wireless commander or away home on a keyfob transmitter Audible panic activates the siren and simultaneously transmits a message via telephone Silent panic only transmits a message via telephone The options are silent panic audible panic and disable...

Страница 14: ...The two options are always on and off after 10 s Note Back Light can be used only if this option is available on the purchased control panel 4 4 23 Duress Fig 4 4 loc 23 A duress alarm ambush message can be sent to the central station if the user is forced to disarm the system under violence or menace To initiate a duress message the user must disarm the system with the duress code 2580 by default...

Страница 15: ...tween AC power failure occurrence and the failure reporting Options 5 minutes 30 minutes 60 minutes or 180 minutes Note To comply with EN requirements set to 60 min max 4 4 36 User Permission Fig 4 4 location 36 Here you determine whether the access to the INSTALLER MODE requires user permission If you select ENABLE the installer mode will be accessible only through the user menu after entering th...

Страница 16: ... door normal bell time 3 m abort time 4 m Note Force arm is not applicable in the UK in USA in USA in USA OK TO EXIT skip exit delay 19 JAM DETECT UL 20 20 EN 30 60 class 6 30 60 disable 21 NOT ACTIVE no act time 3 h no act time 6 h no act time 12 h no act time 24 h no act time 48 h no act time 72 h no act disable 22 BACK LIGHT always on off after 10 s 23 DURESS duress code 2580 Change the code or...

Страница 17: ... to the right 4 5 1 PSTN GSM Fig 4 5 Detail A Area Code Fig 4 5 1 1 Here you enter the system tel area code up to 4 digits Line Prefix Fig 4 5 1 2 Here you enter the number that is used as a prefix to access an outside telephone line if exists Dial Method Fig 4 5 1 3 Here you determine the dialing method used by the automatic dialer built into the PowerMaxExpress control panel The options are Puls...

Страница 18: ...ig 4 5 Detail C Report Events Fig 4 5 3 1 see note in Fig 4 5 Detail C Here you determine which types of event will be reported to central stations Due to lack of space in the display abbreviations are used alarm is alrm alert is alrt and open close is o c The asterisk J is a separator between events reported to central station 1 and events reported to central station 2 Messages are divided by typ...

Страница 19: ...e interval between consecutive telephone line test messages sent to the central station The control panel performs this at regular intervals to verify proper communications The options are test every 5 hours test every 1 2 5 7 14 30 days and test OFF Line Fail Report Fig 4 5 3 21 PSTN Fig 4 5 3 21a Here you determine if the PSTN telephone line disconnection will be reported or not and determine th...

Страница 20: ...e Report is enabled alarms and alerts only can be reported The following siren signal will be sent to private telephone upon event reporting FIRE ON ON ON pause BURGLAR ON continuously EMERGENCY LATCHKEY 2 tone siren like an ambulance Voice report Fig 4 5 4 2 1st Private Tel Fig 4 5 4 2a Here you program the 1st telephone number including area code if required of the private subscriber to which th...

Страница 21: ...click or until the desired option is displayed then click OK a dark box will be displayed at the right side 5 DEFINE COMM 3 DEFINE ZONES 2 ENROLLING 1 NEW INSTL CODE ENTER CODE INSTALLER MODE USER SETTING installer code OK TO EXIT See detail A disable report all all op cl REPORT TO PRVT 4 5 4 1 all alerts alarms alerts op cl VOICE REPORT SMS REPORT TEL 1st private tel Par 4 5 4 2a 3rd private tel ...

Страница 22: ...N UP DOWN Par 4 5 3 22d REPORT EVENTS 1st RPRT METHOD 2nd RPRT METHOD 3rd RPRT METHOD DUAL REPORTING RCVR 2 ACCOUNT RCVR 1 ACCOUNT PSTN GSM RCVR1 PSTN GSM RCVR2 IP RCVR 1 SMS RCVR 1 IP RCVR 2 SMS RCVR 2 PSTN RPRT FORMAT 4 2 PULSE RATE PSTN RPRT RETRY GSM RPRT RETRY AUTO TEST TIME Mast downl code Par 4 5 3 22b downl code AAAA Enter 4 digit code 0000 is not valid xxxx CALLWAIT OFF COD Upload option ...

Страница 23: ...message is displayed only when the PowerMaxExpress alarm system is disarmed In the event of a power failure the Broadband Module will not operate Power AC or battery must be disconnected from the circuit before connecting disconnecting the Broadband Module 4 8 DEFINE PGM PARAMETERS 4 8 1 Preliminary Guidance This mode enables you to determine PGM output a Events conditions selection under which PG...

Страница 24: ...DEFINE CUSTOM This mode allows you to define up to 5 zones names in addition to the zone names that can be defined in the DEFINE ZONES mode see par 4 3 9 DEFINE CUSTOM see figure 4 1a CUST ZONES NAME To edit User Terms use the following buttons on the control panel keypad press to scroll backward press to scroll forward press to change from small caps to big caps press for space EDIT USER TERM 1 E...

Страница 25: ...ocedure tests Broadband Module communication to the IPMP and reports the diagnostic result In case of communication failure detailed information of the failure is reported If the Broadband Module is not registered to the PowerMaxExpress the menu LAN CONNECT TEST will not be displayed The following LAN messages are reported Message Description Unit is ok Broadband Module is functioning correctly Te...

Страница 26: ...Program user codes Enroll keyfobs Set the auto arm option Set arming time Set the squawk option Set the system time and time format Set the date and date format Refer to the User Guide for detailed procedures Caution If after having programmed the user codes the system does not recognize your installer code this indicates you must have programmed a user code that is identical with your installer c...

Страница 27: ... FACTORY DEFLT 13 SERIAL NUMBER 14 START UL DL OK TO EXIT READY 00 00 P1 RDY 00 00 Non Partition mode Partition mode WALK TEST READY First display Figure 4 14 Start UL DL 4 15 ENABLING DISABLING PARTITIONS This menu allows you to enable disable Partition Mode Partitioning allows you to divide the system into a maximum of three independently controllable areas Each area can be armed disarmed separa...

Страница 28: ...ton the exit beeps will be stopped immediately and the system will be armed AWAY Press the DISARM key immediately to disarm the system 5 4 Emergency Transmitter Test Initiate transmission from each transmitter enrolled to an emergency zone according to the list in Table B3 Appendix B For example upon pressing the transmit button of an emergency transmitter enrolled to zone 22 the display should re...

Страница 29: ...hrough the installer s menu Reading and erasing process of the event log is shown in the next drawing Oldest Event Latest Event LIST OF EVENTS CODE _ _ _ _ Enter 4 digit installer code OK TO EXIT CLEAR EVENT LOG OFF TO DELETE Return to normal operation OK I OK I OK I OK I Figure 7 Reading Erasing the Event Log While the system is in normal operation mode click to review the event log Event is disp...

Страница 30: ...d chime option see par 4 3 F After setting the chime option select PARTITION If zone number was set to 05 the PowerMaxExpress display will read Z 0 5 P 1 P 2 P 3 G Press and to select the desired corresponding partitions If a zone is assigned to two or more partitions this indicates that the zone is located in a common area and will behave according to the state of both partitions For a detailed d...

Страница 31: ... disabled the display will read 1way kp No 5 Proceed to step K below When partition is enabled the display will read ACCESS TO PART H Click The display will read C01 P1 P2 P3 I Select the desired partitions that will be associated and can be controlled by this keypad via pushbuttons 1 2 and 3 on the control panel keypad J Click The display will read 1way kp No 5 A dark box will appear at the far r...

Страница 32: ...will be ignored for other assigned armed partitions Interior Acts as defined only after the last assigned partition is armed AWAY In case that one of the partitions is disarmed or armed HOME an alarm initiated from this zone is ignored for all assigned partitions Interior follower Acts as defined only after the last assigned partition is armed AWAY In case that one of the partitions is disarmed or...

Страница 33: ... silent 7 24 h audible 8 Fire 9 Non alarm 10 Emergency 11 Gas 12 Flood 13 Interior 14 Temperature 15 Home delay Zone Locations Note down the intended location for each detector When programming you may select one of 26 available zone names plus 5 custom zone names that you can add see Figure 4 3 Define Zones Zones 29 only is hardwired zones B2 Keyfob Transmitter List Transmitter Data AUX button As...

Страница 34: ...3 Emergency Transmitter List Tx Transmitter Type Enrolled to Zone Name of holder 1 2 3 4 5 6 7 8 9 10 B4 Non Alarm Transmitter List Tx Transmitter Type Enrolled to Zone Name of holder Assignment 1 2 3 4 5 6 7 8 9 10 ...

Страница 35: ...re FJ Fire detector trouble XT Sensor Battery Trouble FR Fire Restore YR System Battery Restore GA Gas alarm YT System Battery Trouble Disconnection GR Gas alarm restore YX Service Required GT Gas trouble 4 2 Event Codes Note The report to central station is on the following zones First wireless siren zone 31 second wireless siren zone 32 GSM zone 33 first 2 way keypad MKP 150 MKP 151 zone 35 seco...

Страница 36: ... 4 6 Event CP Tamper Restore No Active COMM LINE Restore Enter Test Exit Test Auto Test 1st digit 1 1 1 1 1 1 2nd digit 7 8 A D E F Understanding the Scancom Reporting Protocol Data Format The SCANCOM data format consists of 13 decimal digits divided into 4 groups from left to right as shown at the right side Each channel is associated with a specific event as follows 1st C Fire 5th C Alarm cancel...

Страница 37: ...ior Follower Zones Interior Follower zone is a zone that is located between entry exit zone and the alarm system control panel This zone is temporarily ignored by the alarm system during entry exit delay periods to enable you to walk without causing an alarm in front of a motion detector that is associated with the Interior Follower zone after you enter through an entry zone on the way to the cont...

Страница 38: ...ge to the alarm system depending on the setting of an on board DIP switch MCT 100 D Wireless Smoke Detector MCT 425 A photoelectric smoke detector equipped with a PowerCode type transmitter If enrolled to a fire zone it initiates a fire alarm upon detection of smoke MCT 425 E Glass Break Detector MCT 501 An acoustic detector equipped with a PowerCode type transmitter Since it restores automaticall...

Страница 39: ...ash light strobe light every 1 5 seconds Not UL listed MCS 710 MCS 720 MCS 730 E4 PowerMaxExpress Compatible WL Repeater The MCX 610 repeater is a mains powered range extender designed to relay digital data between wireless devices and a control panel MCX 610 Industry Canada Declaration This product meets the applicable Industry Canada technical specifications Le présent materiel est conforme aux ...

Страница 40: ...en accepting the delivery of the Product the Purchaser agrees to the said conditions of sale and warranty and he recognizes having been informed of Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply under certain circumstances The Manufacturer shall be under no liability whatsoever arising out of the corruption and ...

Отзывы: