D-302980
11
4.3 DEFINING ZONE TYPES, NAMES, CHIME ZONES & PARTITION
This mode allows you to assign one of 15 zone types to
each of the system's 29 (wireless & wired) zones. In
addition, it also allows you to assign a name and partition
number (up to three in a PowerMaxExpress Partition
system) to each zone and determine whether the zone will
operate as a chime zone (only while the system is in the
disarmed or Home arming state). When a chime zone is
triggered, chime melody or zone name is heard (there are 2
selectable chime modes - Melody chime or Chime Off).
A list of factory defaults is printed in table 1. You may fill
out the blank columns even before you start and proceed
to program according to your own list.
Remember!
A delay zone is also a perimeter zone by definition.
Zone types are fully explained in Appendix D.
ZONE No
: - -
Zxx: TYPE -
[Zone No.] (e.g. 05)
1. Inter-follow
2. Perimeter
Zxx: NAME - -
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet
(*)
(*)
4. Delay 1
5. Delay 2
6. 24h silent
7. 24h audible
8. Fire
9. Non-alarm
10. Emergency
3. Perim-follow
(see list above)
11. Gas
12. Flood
13. Interior
3. DEFINE ZONES
[installer code]
USER SETTING
ENTER CODE
2. ENROLLING
INSTALLER MODE
<OK> TO EXIT
14. Temperature
15. Home/Delay
Zxx: CHIME
Melody-chime
Chime off
(*)
Zxx: PARTITION
(*)
(see note)
Zxx: KEY ON/OFF
z-key enable
z-key disable
(*)
(**)
OPTIONAL
WALK TEST
READY
(First display)
If Non-alarm is selected
Z05: P1 P2 P3
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet (
UK:
Conservatory)
Den (
UK:
Playroom)
Selectable Zone Names
Dining room
Downstairs
Emergency
Fire
Front door
Garage
Garage door
Guest room
Hall
Kitchen
Laundry room
Living room
Master bath
Master bdrm
Office (
UK:
Study)
Upstairs
Utility room
Yard (
UK:
Garden)
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
31 zone names can be selected, 26 fixed names and 5 custom names (defined by
the installer - see chap. 4.9):
Figure 4.3 - DEFINE ZONES Flow Chart
* The currently saved option is displayed with a dark box at the right side. To review the options, repeatedly click
or
button, until the desired option is displayed, then click
OK
I
(a dark box will be displayed at the right side).
** Key ON/OFF is an optional function that enables you to arm or disarm the system via zones 21-28, 29 or 21-29, provided
that "non-alarm" was pre-defined for these zones.
Table 1 - DEFAULT AND PROGRAMMED ZONE DEFINITIONS
Zone
Zone Type
Zone Name
Chime (melody
No. Default
Programmed
Default
Programmed Zone Name or Off) (*)
1
Delay 1
Front Door
2
Delay 1
Garage
3
Delay 2
Garage Door
4
Perimeter
Back
Door
5
Perimeter
Child
Room
6
Interior
Office
7
Interior
Dining
Room
8
Perimeter
Dining
Room
9
Perimeter
Kitchen