![Visonic POWERMAXEXPRESS - Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/visonic/powermaxexpress/powermaxexpress_installers-manual_1032893027.webp)
D-302980
27
USER SETTING
ENTER CODE
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
5. DEFINE COMM
[installer code]
INSTALLER MODE
4. DEFINE PANEL
COMMUNICATING
TEL # NOT DEFINED
DOWNLOADING
DIAL ATTEMPT FAIL
DOWNLOAD OK
DOWNLOAD FAILED
Displayed during
dialing process
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
If UL/DL server
tel. # was not
defined before
(see par. 4.5.34)
If UL/DL server
tel. # is already
defined (see
par. 4.5.34)
Dialing
OK
Dialing
failed
Download
OK
Download
failed
Displayed during
download process
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by happy
(success) melody
9. DEFINE CUSTOM
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
14. START UL/DL
<OK> TO EXIT
READY 00:00
P1 RDY 00:00
Non-Partition
mode
Partition
mode
WALK TEST
READY
(First display)
Figure 4.14 – Start UL/DL
4.15 ENABLING/DISABLING PARTITIONS
This menu allows you to enable/disable Partition Mode.
Partitioning allows you to divide the system into a
maximum of three independently controllable areas. Each
area can be armed / disarmed separately.
When the partition feature is disabled, zones, user codes
and features will operate the same as in a regular
PowerMaxExpress unit. When partition is enabled, menu
displays are changed to incorporate the partition feature.
15. PARTITIONING
USER SETTING
ENTER CODE
1. NEW INSTL CODE
INSTALLER MODE
[inst. code]
<OK> TO EXIT
enable
disable
Note:
Partitioning is an optional feature
WALK TEST
READY
(First display)
Figure 4.15 – Partitioning
4.16 WALK-TEST
This mode (see Figure 4.1a) provides you with the means to conduct a periodic test, via the walk-test menu, at least once a