4. PROGRAMMING
D-305735 PowerMaster 360 Installer's Guide
33
NETWORK ROAMING
Previously known as "FORCE
HOME NTWK"
You can force the SIM card to use only its "Home Network" and disable it from roaming
to other networks in case the Home Network cannot be found.
Options:
roam disable
;
roam enable
(default).
GPRS ALWAYS ON
Previously known as
"SESSION TIMEOUT"
Define whether the control panel will stay continuously connected "
enabled
", via GPRS
communication, or disconnect "
disabled
" (default), after each report session.
GSM KEEP ALIVE
Some GSM Service providers tend to disconnect the GSM connection if the user has not
initiated any outgoing telephone calls during the last 28 days. To prevent from
disconnecting the GSM connection, you can configure the system to generate a
"keep
alive"
GSM
call
every 28 days
sending a test message either to the first SMS number
(if exists) or alternatively first private telephone number.
Options:
Disable
(default) or
Every 28 days.
TRANS. PROTOCOL
Select the IP protocol used to transfer data over the internet/GPRS.
Options:
TCP
(default); or
UDP.
4.6.3 Configuring Events Reporting to Monitoring Stations
The PowerMaster 360 control panel is designed to report alarm, alerts, troubles and other events and messages to two
Monitoring Stations C.S.1 and C.S.2 via Cellular i.e. GPRS (IP) & SMS or Broadband IP communications channels. In
this section you configure and define all parameters and features required for the reporting of the event messages to
Monitoring Stations such as:
•
The events reported to each of the two Monitoring Stations C.S.1 and C.S.2 and corresponding backups.
•
The communication means (channel) used for the reporting and the backup means (channel) in case of failure.
•
The customer's (subscriber) account number(s) to be reported to each Monitoring Station.
•
The IP addresses, SMS numbers and reporting formats of the corresponding alarm receivers at the two Monitoring
Stations C.S.1 and C.S.2 and the number of reporting retry attempts in case of failure to report.
•
The communication Auto Tests and communication Fail reports.
•
The reporting of certain system function events such as "Confirmed Alarm", "Recent Close", Zone Restore" and
"System Not-Used".
04:COMMUNICATION
⋅ ⋅ ⋅
3:C.S.REPORTING
⋅ ⋅ ⋅
MENU you wish
Enter "
3:C.S.REPORTING
", select the menu you wish to configure (see guidance above and in section 4.6.1), then
refer to the table below which provides you with detailed explanations and configuration instructions for each option.
Option
Configuration Instructions
01:REPORT EVENTS
Define which events (i.e.
Alarms (alrm)
;
Open/close (o/c)
;
Alerts (alrt)
;
All events (all)
;
Maintenance
and
Troubles
) will be reported to the Monitoring Stations.
The minus (-) symbol means "less/except" e.g.
all(-alrt)
means
all
events except
alerts
.
The asterisk (
) is a separator between events reported to
Monitoring Station 1
(C.S.1) and
events reported to
Monitoring Station 2
(C.S.2). For detailed and more complete explanation
see the "
Event Reporting Chart
" at the end of this section.
Options:
all-o/c
backup
(default)
all-o/c
o/c
disable report
all
all
all(-alrt)
alrt
all
backup
all-o/c
all-o/c
alrm
all(-alrm)
Note:
Alarm events (
alrm
) have highest priority and Alert events (
alrt
) have lowest priority.
02:1st RPRT CHAN
If the system is equipped also with Cellular communicators, you must define which of the
communicating channels (i.e. Cellular or Broadband) the system will use as the main channel
(i.e. 1
st
priority) for reporting event messages to Monitoring Stations.
Enter the "1
st
RPRT CHAN"; option and define which of the communication channels the
system will use as the main reporting channel.
Options:
broadband first
(default);
disable
; and
cellular first
.
Important:
If the selected main reporting channel fails, the system will use the other
communication channel to report event messages to Monitoring Stations.
If none
is selected, the reporting to Monitoring Stations will be disabled
.