4. PROGRAMMING
28
D-305735 PowerMaster 360 Installer's Guide
Option
Configuration Instructions
Notes:
1. In some PowerMaster 360 variants, this menu is displayed in the Operation Mode only (see
section 4.13).
2. Since the Soak Test zone does not report an alarm event to the Monitoring Station, the
PowerMaster 360 will not send a “cancel alarm” message to the Monitoring Station even if
disarmed within the Cancel Alarm period.
39:ALARM RESET
Previously known as
"RESET OPTION"
The PowerMaster 360 provides you with the following configurable options for resetting the
alarm condition and rearming the system:
By the user as usual
- by user
(default). By the engineer (installer) by entering and exiting the
"Installer Mode", by entering and exiting the Event Log using the Installer Code or by accessing
the system remotely via the PowerManage server using the Installer Code (
by engineer
). For
accessing the system via the PowerManage server, see the PowerManage User's Guide.
Note:
This feature is not applicable in the USA.
40:ABORT FIRE T.
Select the length of time allowed by the system to abort a Fire alarm. The PowerMaster 360 is
able to provide an “abort interval” that starts upon detection of a Fire event. During this interval,
the buzzer sounds a warning but the siren remains inactive and the alarm is not reported. If the
user disarms the system within the allowed abort interval, the alarm is aborted.
Options:
in 00
(default)/
30
/
60
/
90 seconds
4.5.5 Configuring Sirens Functionality
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 4.5.1.
Option
Configuration Instructions
44:SIREN TIME
Previously known as
"BELL TIME"
Define the period of time the sirens will sound upon alarm.
Options:
1
/
3
/
4
(default)/
8
/
10
/
15
/
20 minute(s)
.
Notes:
1. To comply with
EN
requirements, the "Siren Time" must not exceed 15 minutes.
2. For Canada, the "Siren Time" must be set to 8 minutes.
45:STROBE TIME
Define the length of time the strobe light will flash upon alarm.
Options:
5
/
10
/
20
(default)/
40
/
60 minutes
.
4.5.6 Configuring Audible & Visual User Interface
The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 4.5.1.
Option
Configuration Instructions
53:MEMORY PROMPT
Define whether or not the user will receive "Memory" indication on the Virtual Keypad that an
alarm has been activated. By pressing the
button in standby mode, you can view
details of the alarm memory.
Options:
ON
(default) and
OFF
.
54:LOW-BAT ACK
You can activate or deactivate the "Low Battery Acknowledge" requirement from the user whose
keyfob's battery is low. For further information, see PowerMaster 360 User's Guide Chapter 6.
Options:
OFF
(default) – acknowledge not needed;
ON
– acknowledge required.
56:SCREEN SAVER
With Partition
disabled
The Screen Saver option (when activated) replaces the status display on the virtual keypad
with “PowerMaster 360” display if no key is pressed during more than 30 seconds.
You can activate the Screen Saver and determine whether the status display will resume
following any key press (
refresh by Key
) or by entering a code (
refresh by Code
). If
refresh
by Key
is selected, the first pressing of any key (except Fire and Emergency) will produce the
status display and the second press will perform the key function. For further information, see
the User's Guide, Chapter 1, "Screen Saver Mode".
Options:
OFF
(default);
refresh by Code
and
refresh by Key
.