Visonic POWERART Скачать руководство пользователя страница 16

16

DE5458

WARRANTY

Visonic Ltd. and/or its subsidiaries and its affiliates ("the Manufacturer") warrants its
products hereinafter referred to as "the Product" or "Products" to be in conformance with
its own plans and specifications and to be free of defects in materials and workmanship
under normal use and service for a period of twelve months from the date of shipment by
the Manufacturer.  The Manufacturer's obligations shall be limited within the warranty
period, at its option, to repair or replace the product or any part thereof. The Manufacturer
shall not be responsible for dismantling and/or reinstallation charges. To exercise the
warranty the product must be returned to the Manufacturer freight prepaid and insured.

This warranty does not apply in the following cases:

 improper installation, misuse,

failure to follow installation and operating instructions, alteration, abuse, accident or
tampering, and repair by anyone other than the Manufacturer.
This warranty is exclusive and expressly in lieu of all other warranties, obligations or
liabilities, whether written, oral, express or implied, including any warranty of
merchantability or fitness for a particular purpose, or otherwise.  In no case shall the
Manufacturer be liable to anyone for any consequential or incidental damages for breach
of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not
authorize any person to act on its behalf in the modification, variation or extension of this
warranty. This warranty shall apply to the Product only.  All products, accessories or
attachments of others used in conjunction with the Product, including  batteries, shall be
covered solely by their own warranty, if any.  The Manufacturer shall not be liable for any
damage or loss whatsoever, whether directly, indirectly, incidentally, consequentially or
otherwise, caused by the malfunction of the Product due to products, accessories, or
attachments of others, including batteries, used in conjunction with the Products.

The Manufacturer does not represent that its Product may not be compromised and/or
circumvented, or that the Product will prevent any death, personal and/or bodily injury
and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the
Product will in all cases provide adequate warning or protection. User understands that a
properly installed and maintained alarm may only reduce the risk of events such as
burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such
will not occur or that there will be no death, personal damage and/or damage to property
as a result.

The Manufacturer shall have no liability for any death, personal and/or bodily injury
and/or damage to property or other loss whether direct, indirect, incidental,
consequential or otherwise, based on a claim that the Product failed to function.

 

However, if the Manufacturer is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause or origin, the
Manufacturer's maximum liability shall not in any case exceed the purchase price of the
Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the
complete and exclusive remedy against the Manufacturer.

Warning:

 The user should follow the installation and operation instructions and among

other things test the Product and the whole system at least once a week.  For various
reasons, including, but not limited to, changes in environmental conditions, electric or
electronic disruptions and tampering, the Product may not perform as expected.  The user
is advised to take all necessary precautions for his /her safety and the protection of
his/her property.

6/91

VISONIC LTD. (ISRAEL): 

P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788

VISONIC INC. (U.S.A.): 

10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020. FAX: (860) 242-8094

VISONIC LTD. (UK): 

FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 7300800 FAX: (0870) 7300801

INTERNET WEB SITE

www.visonic.com

VISONIC LTD. 2001      POWERART™     DE5458-  (REV. 0, 9/2001)

Содержание POWERART

Страница 1: ... handed over to the master user after testing the system Appendices A and B to the installation instructions will help you prepare an installation plan Please take time to fill out the forms your job will become much easier and confusion will be prevented Filling out the forms will also help you create a list of detectors and transmitters that must be obtained for the particular application Compat...

Страница 2: ... Siren Signals Continuous intrusion 24 hours panic triple pulse pause triple pulse fire Siren Timeout Programmable 4 minutes by default Internal Sounder Output at least 85 dBA at 10 ft 3 m Supervision Programmable time frame for inactivity alert Special Functions Speech and sound control Powerline Carrier Device Control up to seven X 10 brand units by various factors as programmed Chime zones Diag...

Страница 3: ...ay 3 3 3 3 INSTALLATION INSTALLATION INSTALLATION INSTALLATION 3 1 Unpacking the Equipment Open the cardboard packing box and check whether all items have been included If you find out that an item is missing contact your vendor or dealer immediately 3 2 Supplying Power to the Unit Enrolling the transmitting devices ID codes in the Power Max memory will be easier if carried out before actual insta...

Страница 4: ...used in the system and mark each one in accordance with your deployment plan Program the system now as instructed in the PowerArt programming Guide Publication DE5450P 3 4 Mounting the Bracket A Detaching the Bracket from the Cabinet A notable advantage of the PowerArt is that the unit can be mounted without having to open its cabinet All connectors and terminals are accessible through a rectangul...

Страница 5: ... wall with 4 screws Be sure to insert the special plastic washer into the ring as shown in Figure 8 3 5 Wiring All terminals and connectors are accessible within the opening at the back of the PowerArt see Figure 9 All screw terminal blocks except for EARTH can be pulled out wired appropriately and plugged back in WARNING When plugging terminals back into place be sure to align them carefully with...

Страница 6: ...vertheless refer to Figure 11 and proceed as follows A Hold the cabinet with its top slightly slanted toward yourself and align the trap at the bottom of the cabinet with the dual prong catch at the bottom of the bracket Figure 11 Cabinet to Bracket Assembly Top View B Allow the dual prong catch to enter the trap as far as it will go while slanting the cabinet towards your stomach C Using the dual...

Страница 7: ...napproved by UL A photoelectric smoke detector equipped with a PowerCode type transmitter If enrolled to a fire zone it initiates a fire alarm upon detection of smoke Figure 20 MCT 423 F Wireless Glass Break Detector MCT 501 Fig 21 An acoustic detector equipped with a PowerCode type trans mitter Since it restores automatically after detection this unit does not send a restoral message to the alarm...

Страница 8: ...module The X 10 siren is ready to function upon connection to an electrical power outlet without re programming the Power Max You only have to set the HOUSE CODE and the UNIT CODE selectors on the X 10 siren as follows House Code Set this selector to the letter that follows by alphabetical order the letter that you programmed as a house code for the protected premises For example if the programmed...

Страница 9: ...nd verify that the display shows B Y T I M E R O N and B Y S E N S O R O N A dark box at the extreme right means that these functions are enabled The easiest way to test timed activation is to select the ninth item in the installer s menu 9 USER SETTINGS and set the system clock a few minutes before the relevant start time Do not forget to return the clock to the correct time after completion of t...

Страница 10: ...er the MEMORY message will now blink in the display caused by the tamper alarm you triggered when opening the battery compartment lid Clear it by arming the system and immediately disarming 5 3 Fuse Replacement The PowerArt has two fuses which can burn out Battery Fuse 1A time delay type UL recognized exists in U S variants only Siren Fuse 0 5 A time delay type UL recognized in the U S A or 0 5 A ...

Страница 11: ... 24 h silent 6 24 h audible 7 Fire 8 Non alarm 9 Emergency Zone Locations Note down the intended location for each detector When programming you may select one of 26 available zone names plus 3 custom zone names that you can add see Figure 3 in the Programming Guide A2 Keyfob Transmitter List Transmitter Data AUX button Assignments No Type Holder Status or Arming instant PGM Control X 10 Unit Cont...

Страница 12: ...t Tx Transmitter Type Enrolled to Zone Name of holder 1 2 3 4 5 6 7 8 9 10 A4 SPD 1000 Wireless Detector List SPD 1000 No Enrolled to Zone Location Painting Name 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 ...

Страница 13: ...itter Type Enrolled to Zone Name of holder Assignment 1 2 3 4 5 6 7 8 9 10 APPENDIX B X 10 Unit Assignments Unit Controlled ON ON ON ON ON by Timer ON by Zone No No Appliance by Arming by Memory by Delay by Keyfob ON Time OFF Time a b c 1 2 3 4 5 6 7 ...

Страница 14: ...any This equipment uses the following jacks An RJ31X is used to connect this equipment to the telephone network The REN is used to determine the quantity of devices which may be connected to the telephone line Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of the RENs should not exceed five 5 0 To be cert...

Страница 15: ...DE5458 15 ...

Страница 16: ...others including batteries used in conjunction with the Products The Manufacturer does not represent that its Product may not be compromised and or circumvented or that the Product will prevent any death personal and or bodily injury and or damage to property resulting from burglary robbery fire or otherwise or that the Product will in all cases provide adequate warning or protection User understa...

Отзывы: