Visonic Keyprox Скачать руководство пользователя страница 9

D-303169 KP-160 PG2 Installation Instructions 

3. USING THE KEYPROX 

3.1 Arming and Disarming the System 

Step 

Basic Arming 

User Actions 

Keyboard & Panel 

Response 

Select a 
PARTITION 

(1)   

(if Partition is 
enabled) 

Any combination of 

  

  

 

The selected key 
blinks. 

Arm AWAY 

 + 

[present TAG] 

(4)

 

The selected key and the 
Present Prox Tag key 

(

) begins to blink and 

prompts you to present 
your Tag.

 

The keyprox's LED blinks 
red once to indicate 
transmission of the 
arming command to the 
control panel. The LED 
and the buzzer then 
indicate the control 
panel's response – see 

“System Status and 
Indications”

 section 3.3.

 

 

Arm HOME 

 + 

[present TAG] 

(4)

 

 

Disarm (OFF) 

[present TAG]

 

(4)

 

Quick arm AWAY 

(3)

 (If Quick Arm is 

enabled) 

 (

 2 sec.) 

 

Quick arm HOME 

(3)

 (If Quick Arm is 

enabled) 

 (

 2 sec.) 

 

INSTANT 

(After arming HOME/ AWAY) 

 

(5) (6)

 

LATCHKEY 

(After arming AWAY)

 

(6)

 

Notes

:

 

1.  If Partition is disabled at the control panel, skip Step 1. 

2.  If Partition is enabled at the control panel and a partition was not selected in Step 1, 

Step 2 will activate all of the partitions assigned to the user. 

3.  The Quick arm functions only if enabled at the control panel. 

4.  If the action is not completed while the selected arming key is blinking, the desired 

function will not be executed. 

5.  Press the INSTANT key within maximum 8 seconds timeout period after completing the 

previous step. This will delete the entry delay for the current arming session. 

6.  For LATCHKEY activation, press the LATCHKEY key within maximum 8 seconds 

timeout period after completing the previous step. 

 

You can perform the LATCHKEY and INSTANT functions, one after the other. The 
order is not important. 

 

LATCHKEY and INSTANT functions can be operated only during exit delay. 

Содержание Keyprox

Страница 1: ...llation 3 Wall mounted Installation 4 2 3 Wall Mounting Options 4 2 4 Enrolling the KP 160 PG2 6 2 5 Configuring the KP 160 PG2 Parameters 6 2 6 Enrolling Proximity Tags 8 3 USING THE KEYPROX 9 3 1 Ar...

Страница 2: ...wo partitions by the same or different users see keys marked 7 in the Icon and Key Indications Figure The KP 160 PG2 can be wall mounted using the supplied bracket or be used as a portable unit For co...

Страница 3: ...if battery is replaced by an incorrect type Dispose of used battery according to manufacturer s instructions Figure 1 Battery Insertion Insert two 1 5V batteries in each slot while ensuring battery p...

Страница 4: ...A Tamper B DC Power Connection 2 3 Wall Mounting Options The KP 160 PG2 unit mounting options are illustrated in the following drawings Wall Mounting Figure 4a Wall Mounting 1 Drill 3 mounting holes 2...

Страница 5: ...s 5 Wall Mounting with External Electrical Connector Figure 4b Wall Mounting with External Electrical Connector 1 Secure bracket with 2 screws as shown in the two drawings above 2 Attach the unit to t...

Страница 6: ...nfigure the Keyprox See section 2 5 means scroll and select Note If the KP 160 PG2 is already enrolled you can configure the KP 160 PG2 parameters via the Modify Devices option see Step 2 2 5 Configur...

Страница 7: ...inimum Enabling the function will turn off the display if no key is pressed for more than several seconds Options settings Disabled default and Enabled Notes 1 When the SCREEN SAVER menu on the PowerM...

Страница 8: ...onding User Code is programmed for each enrolled proximity tag code 0000 is not allowed For example T02 Tag Prox must be assigned to User Code 2 and T14 Tag Prox must be assigned to User Code 14 Parti...

Страница 9: ...sec 4 INSTANT After arming HOME AWAY 5 6 LATCHKEY After arming AWAY 6 Notes 1 If Partition is disabled at the control panel skip Step 1 2 If Partition is enabled at the control panel and a partition...

Страница 10: ...2 sends the command 3 3 System Status and Indications When executing a command the keyprox s LED 30 in the Icon and Key Indications Figure blinks red once to indicate transmission of the command to th...

Страница 11: ...indications are provided via the indications in the following table Number Indication 1 What it Means Instructs the user to display the RFID proximity tag in order to initiate a command Volume contro...

Страница 12: ...number appears on the Zone display marked 4 in the Icon and Key Indications Figure To view the zone numbers that are assigned to a Partition press the desired Partition number followed by the key Upo...

Страница 13: ...utton initiates the X 10 function and the PGM X 10 display marked 4 in the Icon and Key Indications Figure will read 01 Short press of the button initiates the PGM function and the PGM X 10 display wi...

Страница 14: ...cy 4 years for typical use Power source optional 5 12VDC Back light Blue white or black white Operating Temperature 0 C to 55 C 32 F to 131 F Dimensions WxLxD 150x100x20mm 5 7 8 x 3 7 8 x 13 16 in Wei...

Страница 15: ...T FAILED TO FUNCTION However if the Manufacturer is held liable whether directly or indirectly for any loss or damage arising under this limited warranty THE MANUFACTURER S MAXIMUM LIABILITY IF ANY SH...

Страница 16: ...it for repair then you must ensure that it is returned as identified by your supplier This product is not to be thrown away with everyday waste Directive 2002 96 EC Waste Electrical and Electronic Eq...

Отзывы: