background image

D-303169 KP-160 PG2 Installation Instructions 

2.4 Enrolling the KP-160 PG2 

Refer to the PowerMaster panel's Installer Guide and follow the procedure under the 

"

02:ZONES/DEVICES

"

 option of the Installer Menu. A flowchart of the procedure is provided 

below. 

Step Action 

LCD 

Display 

Enter the Installer menu and select 

02:ZONES/DEVICES

” 

 

Select "

ADD NEW DEVICE

" Option  

See Note 

 

 

 

Enroll the device or enter the 7-digit 
code that appears on the device's 
sticker. 

 

 

Select the desired keyprox Number 

 

 

Configure the settings of the device 

 

Configure the Keyprox 

See section 2.5 

 means scroll 

 and select 

 

Note: 

If the KP-160 PG2 is already enrolled, you can configure the KP-160 PG2 parameters 

via the “Modify Devices” option – see Step 2. 

2.5 Configuring the KP-160 PG2 Parameters 

Enter the 

 menu and follow the configuration instructions for the 

KP-160 PG2 keyprox. 

Option Configuration 

Instructions 

 

Define the active tamper.  

 

Option settings

:

 Disabled

 (default); 

All Tampers

 and 

Battery 

Cover

 

Define whether or not the control panel will monitor supervision 
messages sent by the keyprox (see Note). 

 

Option settings

:

 

ON 

(default) or

 OFF.

 

SUPERVISION 

TAMPERS 

K07.DEV SETTINGS 

 

K07.DEV SETTINGS 

ID No. 374-XXXX 

K07: LCD Keypad 

ENTR ID:XXX-XXXX 

ENROLL NOW or 

MODIFY DEVICES 

ADD NEW DEVICES 

02.ZONES/DEVICE

Содержание Keyprox

Страница 1: ...llation 3 Wall mounted Installation 4 2 3 Wall Mounting Options 4 2 4 Enrolling the KP 160 PG2 6 2 5 Configuring the KP 160 PG2 Parameters 6 2 6 Enrolling Proximity Tags 8 3 USING THE KEYPROX 9 3 1 Ar...

Страница 2: ...wo partitions by the same or different users see keys marked 7 in the Icon and Key Indications Figure The KP 160 PG2 can be wall mounted using the supplied bracket or be used as a portable unit For co...

Страница 3: ...if battery is replaced by an incorrect type Dispose of used battery according to manufacturer s instructions Figure 1 Battery Insertion Insert two 1 5V batteries in each slot while ensuring battery p...

Страница 4: ...A Tamper B DC Power Connection 2 3 Wall Mounting Options The KP 160 PG2 unit mounting options are illustrated in the following drawings Wall Mounting Figure 4a Wall Mounting 1 Drill 3 mounting holes 2...

Страница 5: ...s 5 Wall Mounting with External Electrical Connector Figure 4b Wall Mounting with External Electrical Connector 1 Secure bracket with 2 screws as shown in the two drawings above 2 Attach the unit to t...

Страница 6: ...nfigure the Keyprox See section 2 5 means scroll and select Note If the KP 160 PG2 is already enrolled you can configure the KP 160 PG2 parameters via the Modify Devices option see Step 2 2 5 Configur...

Страница 7: ...inimum Enabling the function will turn off the display if no key is pressed for more than several seconds Options settings Disabled default and Enabled Notes 1 When the SCREEN SAVER menu on the PowerM...

Страница 8: ...onding User Code is programmed for each enrolled proximity tag code 0000 is not allowed For example T02 Tag Prox must be assigned to User Code 2 and T14 Tag Prox must be assigned to User Code 14 Parti...

Страница 9: ...sec 4 INSTANT After arming HOME AWAY 5 6 LATCHKEY After arming AWAY 6 Notes 1 If Partition is disabled at the control panel skip Step 1 2 If Partition is enabled at the control panel and a partition...

Страница 10: ...2 sends the command 3 3 System Status and Indications When executing a command the keyprox s LED 30 in the Icon and Key Indications Figure blinks red once to indicate transmission of the command to th...

Страница 11: ...indications are provided via the indications in the following table Number Indication 1 What it Means Instructs the user to display the RFID proximity tag in order to initiate a command Volume contro...

Страница 12: ...number appears on the Zone display marked 4 in the Icon and Key Indications Figure To view the zone numbers that are assigned to a Partition press the desired Partition number followed by the key Upo...

Страница 13: ...utton initiates the X 10 function and the PGM X 10 display marked 4 in the Icon and Key Indications Figure will read 01 Short press of the button initiates the PGM function and the PGM X 10 display wi...

Страница 14: ...cy 4 years for typical use Power source optional 5 12VDC Back light Blue white or black white Operating Temperature 0 C to 55 C 32 F to 131 F Dimensions WxLxD 150x100x20mm 5 7 8 x 3 7 8 x 13 16 in Wei...

Страница 15: ...T FAILED TO FUNCTION However if the Manufacturer is held liable whether directly or indirectly for any loss or damage arising under this limited warranty THE MANUFACTURER S MAXIMUM LIABILITY IF ANY SH...

Страница 16: ...it for repair then you must ensure that it is returned as identified by your supplier This product is not to be thrown away with everyday waste Directive 2002 96 EC Waste Electrical and Electronic Eq...

Отзывы: