![Visonic Keyprox Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/visonic/keyprox/keyprox_user-manual_1032917008.webp)
8
D-303169 KP-160 PG2 Installation Instructions
sections of the control panel’s Installer Guide (“OUTPUTS” menu)
and User Guide (“SCHEDULER” menu).
Option settings:
Not Used
,
Status
(default);
Stop Beeps
,
Skip
exit delay
; and
X-10
(PGM
)
.
* Applicable only to control panels that support the voice option.
Define whether or not to report power failure.
Option settings:
NOT Connected
(default) and
Connected to AC
.
2.6 Enrolling Proximity Tags
You can enroll proximity tags in the PowerMaster panel either via the KP-160 PG2 keyprox,
as described below, or through the PowerMaster control panel, as described in the
corresponding section of the control panel's User or Installer Guide.
Each proximity tag corresponds to its User Code. Therefore, be sure that a corresponding
User Code is programmed for each enrolled proximity tag (code "0000" is not allowed). For
example, "T02:Tag <Prox>" must be assigned to User Code 2 and "T14:Tag <Prox>" must
be assigned to User Code 14. Partition authorization of each proximity tag is identical to that
of the corresponding User Code. For example, if User Code 3 is set to Partitions 1 and 3,
"T03:Tag <Prox>" will also be set to Partitions 1 and 3.
Step
Action
LCD Display
1
Enter the Installer menu of the control panel and
go to “
02:ZONES/DEVICES
”
2
Select "
ADD NEW DEVICE
" Option
3
When "
ENROLL NOW
"
is displayed, press the
AWAY key (
) on the KP-160 PG2. The
AWAY key and the Present Prox Tag key (
)
begin to blink
4
Present the proximity tag to the KP-160 PG2
within the timeout period. If the enrollment is
successful the display reads
"
DEVICE
ENROLLED
"
and then shows the device details
T01:Tag (Prox)
DEVICE ENROLLED
ENROLL NOW or
MODIFY DEVICES
ADD NEW DEVICES
02.ZONES/DEVICE
AC POWER Connect