Installation
51
© 2015 Vision Engraving Systems
192.168.5.101, then the machine is set for a Static IP addess of 192.168.5.101. If you need to manually
enter an IP address different than this, see the Direct Connection to Computer section earlier in this
manual.
+
Then
ALT + Stop button
then B2
- Holding down the ALT
button and pressing the Stop button and then pressing the B2 button will load a test job into the machine.
Pressing Start will load the job and pressing Start again will run the job.
+
ALT + Limits On/Off button
- Holding down the ALT button and pressing the Limits
On/Off button will display a test menu on the LCD screen. Pressing the X limit switch with your hand will
change the X from 0 to 1. Pressing the Y limit switch with your hand will change the Y from 0 to 1.
Pressing the Z limit switch with your hand will change the Z from 0 to 1. Pressing the proximity switch
will change the P from 0 to 1. The S is reserved for future use. If there is a drive board fault inside the
controller, the F will display 1.