6.5 ERROR MESSAGES ON THE CONSOLE
Class
Level
Error
Code
Description
Conditioned
Solution
B
0140
Incline motor operation fail.
When the elevation is supposed to move,
it does not. When the error happens, the
elevation will be locked. The command
initialize is needed to unlock.
1. Check connection of the elevation motor.
2. MCB LED check.
3. Replace the incline motor.
C
01A0
Incline motor disconnection.
When the elevation position cable is not
connected.
1. Check connection of the elevation motor.
2. MCB LED check.
3. Replace the incline motor.
C
01A4
Main motor U phase
disconnection.
Main motor U phase wire disconnected. 1. Check the connection of the motor.
2. Replace the motor.
3. Replace the MCB.
C
01A5
Main motor V phase
disconnection.
Main motor V phase wire disconnected.
1. Check the connection of the motor.
2. Replace the motor.
3. Replace the MCB.
C
01A6
Main motor W phase
disconnection.
Main motor W phase wire disconnected. 1. Check the connection of the motor.
2. Replace the motor.
3. Replace the MCB.
C
01A8
Main motor over current.
Main motor over current (7 Amps)
1. Check the connection of the motor.
2. Check the condition of the deck / belt.
3. Do an amp check.
C
01AB
Inverter error.
Internal error of the inverter.
1. Check the MCB errors.
2. Replace the MCB.
C
01AD
Inner electron over
temperature: motor over
loading.
When it thinks the user is over 130 KG
(350 lbs) making the motor overload.
Check the condition of the deck / belt, replace
as needed.
C
02A0
Main motor fail.
The belt does not move when it is
supposed to move.
1. Check the power input connections.
2. Do a resistance check on the motor,
replace if needed.
3. MCB replacement.
C
02A1
Over AC power input voltage. Power input voltage over range.
Check the power input connections.
C
02A2
Over / low DC bus voltage.
Power input voltage over range.
Check the power input connections.
C
02A8
Inverter circuit of motor driver
failed.
Motor resistance is closed.
Do a resistance check on the motor, replace if
needed.
C
02AD
MCB over temperature.
MCB over temperature.
1. Check the MCB temperature.
2. Check the cooling fan for function.
3. Replace the MCB.
C
02B5
Inverter senses the normal
rated current is over 150% for
60 seconds.
Inverter senses the normal rated
current is over 10.5 Amps for at least 60
seconds.
Check the connection of the motor.
C
02B6
Speed up is over current.
Software error.
Check the condition of the deck / belt, replace
as needed.
C
02B7
Speed down is over current. Software error.
Replace the MCB.
C
02B8
Running status over current. Software error.
1. Check the connection of the motor.
2. Check the condition of the deck / belt,
replace as needed.
C
02B9
The inner memory IC data
write error.
MCB failure.
Replace the MCB.
C
02BA
The inner memory IC data
read error.
MCB failure.
Replace the MCB.
C
02BC
Ground connection of fuse
error.
MCB failure.
Replace the MCB.
C
02BD
Inverter hardware interrupt
error.
MCB failure.
Replace the MCB.
C
04A0
No communication response. Digital Communication failed.
1. Check the console cable connection at the
MCB and UCB.
2. Check the MCB LEDs.
3. Replace the console cable, MCB, or UCB.
CHAPTER 6: TROUBLESHOOTING