4-5. SUGGESTIONS BEFORE MEASUREMENT
- The first time you use the device, please charge the battery using the USB port provided. Con-
nect the USB cable provided to your computer to charge the device. When the device is fully
charged, please unplug the USB cable.
- Avoid eating, smoking or exercising 30 minutes before taking measurements. Relax for 15 mi-
nutes before taking blood pressure.
- Stress increases blood pressure. Avoid taking measurements during stressful periods.
- You must take blood pressure in a calm environment and you must be relaxed and seated with
your arm on a table.
- Remain stationary and do not speak whilst taking blood pressure.
4-6. INSTRUCTIONS
See diagram B page 2
Do not take measurements over clothing. Remove jewelry from the arm you are measuring before taking
measurement (watch, ring, bracelet etc.).
- Sit down on a chair with your feet flat on the floor (do not cross your legs).
- Ensure your mobile phone or tablet with the BewellConnect® app is within reach.
- Put the blood pressure monitor around the arm with the orange marker at the bottom.
- It must be 0.7 - 1.1 in / 2-3 cm from elbow crease. The orange marker must lie on the inside arm’s
artery.
- Close the velcro (not too tight).
- Press ON/START to turn the blood pressure monitor on. The blue LED lights up.
- Put your arm on the table, palm up so that the blood pressure monitor is level with the heart.
- Remain seated and calm for 5 minutes before taking measurement.
Note : For more reliable results, take measurements on the same arm.
The measurement results are given
for information. If in doubt about your results, please contact your doctor.
4-7. DOWNLOAD APPLICATION
The following information may be altered.
bw
My
Download the BewellConnect® app on your mobile phone or tablet :
- App store or Google Play
- scan the QR Code on the side of the box
Then click on the
My
Tensio icon.
4-8. USER GUIDE
Launch the BewellConnect® app and click on
My
Tensio.
- Press START on the screen (app) to begin measurement.
- The armband inflates automatically. 3 blood pressure measurements are repeated automatically.
- The armband inflates and deflates three times in a row based on the
My
Tensio app procedure.
Do not remove the armband before the 3 blood pressure measurements. The measurements
are automatically sent to the app via Bluetooth 4.0.
- Once the measurements have been taken, the average of the 3 is displayed on the app screen.
- Press the ON/START to turn it off. The unit automatically turns off after approximately 1 minute.
- To determine which arm you will continue to take readings on, do both on your first reading.
In the event of asymmetrical blood pressure (right systolic blood pressure-left systolic blood
press >20 mmHg), take reading from the arm with the highest value except in the event of
contraindications in this arm.
Notes :
- The measurement will be too low if the armband is higher than the heart or too high if it is lower than
the heart.
- If you want to stop the blood pressure measurement at any point, press the ON/START to turn it off.
- Speak to your doctor if you have any questions about using the blood pressure monitor.
4-9. MEASUREMENT RESULTS
The app automatically evaluates the MAM (Measurement Average Mode) and uses WHO color
grading to provide the result.
5. HOW TO MAINTAIN AND STORE THE UNIT
- Use a dry soft cloth to clean the unit. If necessary, use a cloth lightly dampened with tap water.
- Do not use alcohol, benzene, thinner or other harsh chemicals to clean the device or cuff.
- Before using please wash your hand. Do not wash or wet the cuff.
- Avoid placing the unit where there is direct sunlight, high humidity or dust.
- Roll up the pressure armband and store in its case.
6. HOW TO PREVENT A MALFUNCTION
- Do not drop the device and avoid sudden jars or shocks.
- Do not insert other objects into any holes.
- Do not attempt to disassemble the unit.
- Do not put the unit in water.
- The monitor might not meet its performance specifications or may cause safety hazard if
stored or used outside the specified temperature and humidity ranges in specifications.
Содержание bewell connect MyTensio BW-BA1
Страница 1: ...BewellConnect BW BA1 User Manual 122016V1 1 BW BA1 MyTensio...
Страница 4: ...BewellConnect BW BA1 User Manual 122016V1 4...
Страница 5: ...BewellConnect BW BA1 User Manual 122016V1 5 BewellConnect BW BA1 User Manual 122014 BW BA1 MyTensio EN...
Страница 16: ...BewellConnect BW BA1 User Manual 122016V1 16...
Страница 17: ...BewellConnect BW BA1 User Manual 122016V1 17 BewellConnect BW BA1 User Manual 122014 BW BA1 MyTensio ES...
Страница 28: ...BewellConnect BW BA1 User Manual 122016V1 28...
Страница 29: ...BewellConnect BW BA1 User Manual 122016V1 29 BewellConnect BW BA1 User Manual 122014 BW BA1 MyTensio FR...
Страница 41: ...BewellConnect BW BA1 User Manual 122016V1 41...
Страница 42: ...BewellConnect BW BA1 User Manual 122016V1 42...
Страница 43: ...BewellConnect BW BA1 User Manual 122016V1 43...
Страница 45: ...BewellConnect BW BA1 User Manual 122016V1 45 WA R R A N T Y e e e...
Страница 51: ...BewellConnect BW BA1 User Manual 122016V1 51 y s...