background image

 
 

 

17A 

  7. Fixture Cleaning   

The cleaning of internal must be carried out periodically to optimize light output. Cleaning 

frequency depends on the environment in which the fixture operates: damp, smoky or particularly 

dirty surrounding can cause greater accumulation of dirt on the fixture’s optics. 

y

 

Clean with soft cloth using normal glass cleaning fluid. 

y

 

Always dry the parts carefully. 

y

 

Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 

days. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание BW-1210 QW

Страница 1: ...BW 1210 QW User Manual Please read the instructions carefully before use...

Страница 2: ...How To Set The Fixture 5 3 1 Control Panel 5 3 2 Main Functions 6 4 How To Control The Unit 12 4 1 Master Slave Built In Preprogrammed Function 12 4 2 DMX Controller 12 4 3 DMX 512 Configuration 14 5...

Страница 3: ...the unit y It s important to ground the yellow green conductor to earth in order to avoid electric shock y Maximum ambient temperature Ta 40 Don t operate it where the temperature is higher than this...

Страница 4: ...ct the mains power if the fixture is not used for a long time y DO use original packing materials once transport it again y To prevent or reduce the risk of electrical shock or fire do not expose the...

Страница 5: ...pre programmed movement patterns and 4 5 7 DMX channels Easy installation with swivel tilt mechanism for quick positioning Easy cabling with a specially designed power and DMX compartment With variou...

Страница 6: ...ions 4 DOWN To go backward in the selected functions 5 UP To go forward in the selected functions 6 Power IN Water proof connectors for power input 7 Power OUT Water proof connectors for power output...

Страница 7: ...NTER button to setup or it will automatically return to the main functions without any change after idling one minute Back to the functions without any change press the MENU button The main functions...

Страница 8: ...7A...

Страница 9: ...xit menu mode without any change after one minute To go back to the functions without any change press the MENU button Show Mode Select the press the ENTER button and the display will blink Use the DO...

Страница 10: ...and the display will blink Use the DOWN and UP button to select the Red Green Blue Once selected press the ENTER button to confirm and use the DOWN and UP button to adjust the value between and then p...

Страница 11: ...s the MENU button to show on the display Press the ENTER button and the display will blink Use the DOWN and UP button to change the password from the Once select press the ENTER button to setup or aut...

Страница 12: ...is shown on the display Press the ENTER button and the display will blink Use DOWN and UP button to select the display is always on or display off 20 seconds after exit menu mode Once select press th...

Страница 13: ...s to give an automatic sound activated synchronized light show This function is good when you want an instant show In Master Slave mode the first fixture whose DMX input jack has with nothing connect...

Страница 14: ...13A Please refer to the following diagram to address your DMX512 channel for the first 4 units...

Страница 15: ...14A 4 3 DMX 512 Configuration 4 5 7 Channels Mode...

Страница 16: ...or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output a...

Страница 17: ...oltage Measure the mains voltage on the main connector Incorrect DMX cable connection Check DMX connectors and cables to see if link properly Repair or replace damaged wires Incorrect address assignme...

Страница 18: ...vironment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics y Clean with soft cloth using normal glass cleaning...

Страница 19: ...th the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598...

Страница 20: ...19A...