![VisIC V22N65A-HBEVB Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/visic/v22n65a-hbevb/v22n65a-hbevb_user-manual_1030893043.webp)
VisIC V22N65A GaN Half Bridge Evaluation Board
User Manual USG-022650-004
All the above is subject to T’s & C’s agreed by the parties – VER 3.4
Preliminary Data Sheet: VisIC, Ltd. reserves the right to make design improvement changes at any time.
www.visic-tech.com
User Guide USG-022650-001
Page | 42
Air Cooling:
Figure 13 Air cooling Setup
Air Cooling is another option for dissipating heat from the V22N65A SMT package.
One 60X60X15 fan cooled heat sink is used to cool 2 power devices in this configuration.
Although less efficient in dissipating heat, this setup is significantly less bulky and easier to work with,
when easy access to the board and its’ components is required.
Air Cooling Bill of materials(BOM):
Number
Property
Number of units
Remarks
1
Heat sink Aluminum 60X60
1
DCC60U-V
2
Fan 12V DC
1
3
Springs
4
4
Washer M3
4
5
Nuts M3
4
6
Metal Screws M3 60mm
4
Air Cooling Installation instructions:
1.
Insert springs into the M3 metal screws.
2.
Insert the screws (with the springs around them) into the fan.
3.
Mount the heatsink unto the screws.
4.
Apply approx. 0.1[mm] of thermal interface material on the V22N65A devices.