eco-CONTROL EC200-B
Operation and maintenance instructions
5.16
Bleed the dispenser (after filling, cleaning)
The dispenser must be bled when it is used for the first time and each time after refilling
or cleaning. Do this in accordance with the notes given in the operating instructions of the
dispenser.
It is best to use the
start / stop program
with a medium flow rate to control the dispenser.
5.17
Service
5.17.1 Operating information
5.17.2 Formatting the chipcard
Caution:
Dosing system Do
not
switch on before medium has been fed in. There is a
danger of
damage.
Even a
brief
period of dry running can
lead to the stator being
destroyed.
• Press the
PRG
key,
system selection menu
,
display 2 appears.
• Select and confirm the
Service
function,
display 38 appears.
D
is
pl
ay
2
All the main system and operating times are displayed.
The language for the displays can be set.
D
is
pl
ay
3
8
• Using the chipcard
• Press the
PRG
key,
the start screen
, display 1 appears.
• Press and hold down the
START
key.
• Press the
PRG
key.
• Release both keys again, the chipcard is reformatted, and
any data on it is deleted. A confirmation message appears
on the display:
Chipcard initialized and ok.
D
is
pl
ay
1
Start/stop
Time program
Calibration auto
Calibration manuel
Teach in function
Administration
Quantity program
10 47h
Fr 18.03.11
Service
Esc OK
10 47h
Fr 18.03.11
ViscoTec
System totally
00002h13m
Serial number
1034
Software
Motor totally
Type of pump
Language
00152h26m
English
eco-PEN450
C200 V1.004
E
C200
E
Error msg
10
47h
Fr
18.03.11
Dosierstation
eco
-
Contro
l
Ec200