eco-CONTROL EC200-B
Operation and maintenance instructions
5.10.8 Analogue Input
Description:
The flow rate of the connected pump(s) is controlled proportional to the
applied analogue signal (V or mA).
This function is only active in the
Start / Stop program
.
Note:
Whatever the setting of the flow rate in the
Start / Stop program
, the maximum
flow rate of the pump (see table above) must always be assumed. This setting does
not affect the return.
Switching the analogue input on / off
• Press the
PRG
key,
system selection menu
, display 2
appears.
• Select and confirm
Administration
, the
Administration
menu
, display 25 appears.
D
is
pl
ay
2
• Select
Analogue Input
, display 43 appears.
The current setting is shown in the status bar.
D
is
pl
ay
2
5
• Select the desired setting and press
Navi wheel
, the status
bar displays
Press OK to accept.
• Select the
OK
button and confirm, the setting is activated.
D
is
pl
ay
4
3
Technical connection data on the system connector (15)
Pin
Analogue signal
Input resistance / resolution
Pump
ml/min
A1
0-10V
Ri = k 20 k
/ 10 bit
ecoPEN300
echPEN450
ecoPEN600
echPEN700
0 - 0,1
0 - 11
0 -34
0 - 100
A2
04-20mA
Ri = 100
/ 10Bit
Maximum input v5V
GND
GND Analog
Start/stop
Time program
Calibration auto
Calibration manuel
Teach in function
Administration
Quantity program
10 47h
Fr 18.03.11
Service
Esc OK
Change program
Tolerance of pressure
Password protection
Analog input
Adjust time
Select program
Esc
Analog input
Analog inactive
Off
OK
A1
A2