background image

Start Configuration((+SETF)) 

 

End  Configuration((+ENDF)) 

 

14 

3.2 UPC-E 
Reading 

 

OFF((+G1A)) 
 
Code ID (Default

G) 

 

<20H-7EH>((+G2A)) 
 
UPC-E Convert to UPC-A 

 

<OFF>((+G3A)) 
 
 
Transmit Check Character 

 

OFF((+G4A)) 
 
 
Truncate Leading Zero 

 

<OFF>((+G7A)) 
 

 
 
 
 

 

<ON>((+G1B)) 
 
 
 
 
 
 
 

 

ON((+G3B)) 
 
 
 

 

<ON>((+G4B)) 
 
 
 

 

ON((+G7B)) 

Truncate Leading Digit(Default:00) 

 

<00H-08H>((+G5A)) 
Truncate Last Digit(Default:00) 

 

<00H-08H>((+G6A)) 
Select Insertion(Default:00) 

 

<00H-02H>((+G9A)) 

Содержание BT310D

Страница 1: ...Programming BT Scanner For BT310N BT310D User s Manual Restore Factory Default BT Firmware version Ver 1 2...

Страница 2: ...e Mode The scanner provides another way to transmit data beside BT mode Connecting Micro USB cable is to switch from BT mode to Cable online mode and also in battery charger Memory Mode 1 Memory Mode...

Страница 3: ...ou must set a longer sleep time 60 Min 2 Hours Never Sleep or alternatively you must set the host side to reconnect the connection after bar code reader returns from sleep mode Memory Mode Bluetooth M...

Страница 4: ...4 Keyboard Language USA Germany Czech Spain French Portugal Italy UK Japan Czech QWERTY Turkey Q Slovak Turkey F...

Страница 5: ...5 Hungary Belgium FR Brazil PT Canada FR Croatia Slovenia Denmark Finland Latin America ES Netherland Norway Poland Serbia Sweden Swiss...

Страница 6: ...ep Control Mute Beep On Normal Up Low Case Swap A a All Upper Case a A All Lower Case A a Num Lock Set Num Lock off Nums transmit by keyboard Num Lock on Nums transmit by keypad IOS Screen Keyboard on...

Страница 7: ...7 Set Sleep Mode 1 Min 6 Min 12 Min 30 Min 60 Min 2 Hours Never Sleep...

Страница 8: ...8 Keyboard Wedge function Num Lock OFF Caps Lock Normal All Upper Case a A ON Up Low Case Swap A a All Lower Case A a Beep Control Setting Beep On Mute...

Страница 9: ...ssage Terminator None C9A CR C9C TAB C9E CR LF C9B LF C9D 2 2 Character Installation The preamble and postamble character You can put 10 ASCII at most in front of the barcode data When the installatio...

Страница 10: ...to the G2 insertion 10 Scan the End Configuration The position of G1 G2 character insertion To select a character insert to the barcode You can t insert any character while the installation is 0 1 Sc...

Страница 11: ...00 Appendix A E8A G2 Character Insertion Position Default 00 Appendix A E9A Code ID Transmission ON EAA OFF EAB 2 3 Other Installation Scanning Precision You can set to scan once or twice and then tra...

Страница 12: ...ing OFF F1A Code ID Default F 20H 7EH F2A UPC A convert to EAN 13 OFF F3A Transmit Check Character OFF F4A Truncate Leading Zero OFF F5A ON F1B ON F3B ON F4B ON F5B Truncate Leading Digit Default 00 0...

Страница 13: ...Start Configuration SETF End Configuration ENDF 13 3 1 UPC A Add On 2 5 None F8A 5 digit F8C AUTO_Enable F8E 2 digit F8B 2 or 5 digit F8D...

Страница 14: ...de ID Default G 20H 7EH G2A UPC E Convert to UPC A OFF G3A Transmit Check Character OFF G4A Truncate Leading Zero OFF G7A ON G1B ON G3B ON G4B ON G7B Truncate Leading Digit Default 00 00H 08H G5A Trun...

Страница 15: ...Start Configuration SETF End Configuration ENDF 15 3 2 UPC E Add On 2 5 None G8A 5digit G8C AUTO_Enable G8E 2digit G8B 2 or 5 digit G8D...

Страница 16: ...ENDF 16 3 3 EAN 13 Reading OFF H1A Code ID Default H 20H 7EH H2A Transmit Check Character OFF H3A ON H1B ON H3B Truncate Leading Digit Default 00 00H 0DH H4A Truncate Last Digit Default 00 00H 0DH H5...

Страница 17: ...Start Configuration SETF End Configuration ENDF 17 3 3 EAN 13 Add On 2 5 None H6A 5 Digit H6C AUTO_Enable H6E 2 Digit H6B 2or 5 Digit H6D ISBN ISSN Convert OFF H7A ON H7B...

Страница 18: ...n ENDF 18 3 4 EAN 8 Reading OFF I1A Code ID Default I 20H 7EH I2A Transmit Check Character OFF I3A ON I1B ON I3B Truncate Leading Digit Default 00 00H 08H I4A Truncate Last Digit Default 00 00H 08H I5...

Страница 19: ...Start Configuration SETF End Configuration ENDF 19 Add On 2 5 None I6A 5 digit I6C AUTO_Enable I6E 2 digit I6B 2 or 5 digit I6D...

Страница 20: ...nd Configuration ENDF 20 3 5 Code 39 Reading OFF J1A Code ID Default J 20H 7EH J2A Verification OFF J3A Transmit Check Character OFF J4A Min Length Default 01 01H 50H J6A ON J1B ON J3B ON J4B Max Leng...

Страница 21: ...tandard Code39 J9A Trioptic CODE39 J9C Full ASCII Code39 J9B Transfer Start End Character OFF JDA ON JDB Code 39 Concatenation OFF JFA ON JFB Truncate Leading Digit Default 00 00H 32H JAA Truncate Las...

Страница 22: ...odabar Reading OFF K2A Code ID Default K 20H 7EH K2A Verification OFF K3A Transmit Check Character OFF K4A ON K1B ON K3B ON K4B Truncate Leading Digit Default 00 00H 7EH K6A Truncate Last Digit Defaul...

Страница 23: ...ETF End Configuration ENDF 23 3 6 Codabar Start End Character Type ABCD ABCD K8A abcd tn e K8C abcd abcd K8B Transmit Start End Character OFF K9A Min Length Default 06 01H 50H KAA ON K9B Max Length De...

Страница 24: ...ult L 20H 7EH L2A Verification OFF L3A Transmit Check Character OFF L4A ON L1B ON L3B ON L4B Select Insertion Default 00 00H 02H L9A Truncate Leading Digit Default 00 00H 7EH L7A Truncate Last Digit D...

Страница 25: ...ault M 20H 7EH M2A Verification OFF M3A Transmit Check Character OFF M4A ON M1B ON M3B ON M4B Truncate Leading Digit Default 00 00H 7FH M8A Truncate Last Digit Default 00 00H 7FH M9A Select Insertion...

Страница 26: ...ation ENDF 26 UCC EAN128 OFF M6A FNC1 Transmit OFF M7A FNC2 Concatenation OFF M5A ON M6B ON M7B ON M5B Application ID transmit 01 Terminator MDA 01 Terminator MDA OFF Terminator MDC 01 Terminator MDB...

Страница 27: ...A Code OFF V1A ON V1B 3 9 Interleaved 2 of 5 Reading OFF N1A Code ID Default N 20H 7EH N2A Verification OFF N3A Transmit Check Character OFF N4A ON N1B ON N3B ON N4B Truncate Leading Digit Default 00...

Страница 28: ...ength Default 06 01H 50H N7A Max Length Default 50H 01H 50H N8A 3 10 Industrial 2 of 5 Reading OFF O1A Code ID Default O 00H 7EH O2A Verification OFF O7A Transmit Check Character OFF O8A ON O1B ON O7B...

Страница 29: ...Length Default 06 01H 50H O3A Max Length Default 50H 01H 50H O4A 3 11 Matrix 2 of 5 Reading OFF P1A Code ID Default P 20H 7EH P2A Verification OFF P3A Transmit Check Character OFF P4A ON P1B ON P3B O...

Страница 30: ...Length Default 06 01H 50H P7A Max Length Default 50H 01H 50H P8A 3 12 China Post Code Reading OFF Q1A Code ID Default Q 20H 7EH Q2A Verification OFF Q3A Transmit Check Character OFF Q4A ON Q1B ON Q3B...

Страница 31: ...on Default 00 00H 02H Q9A Min Length Default 06 01H 50H Q7A Max Length Default 50H 01H 50H Q8A 3 13 MSI Plessey Reading OFF R1A Code ID Default R 20H 7EH R2A Verification OFF R3A MOD 10 R3B Transmit C...

Страница 32: ...Start Configuration SETF End Configuration ENDF 32 Truncate Leading Digit Default 00 00H 3CH R5A Truncate Last Digit Default 00 00H 3CH R6A Select Insertion Default 00 00H 02H R9A...

Страница 33: ...Start Configuration SETF End Configuration ENDF 33 3 13 MSI Plessey Min Length Default 06 01H 50H R7A Max Length Default 50H 01H 50H R8A...

Страница 34: ...g OFF S1A Code ID Default S 20H 7FH S2A Verification OFF S3A Transmit Check Character OFF S4A ON S1B ON S3B ON S4B Truncate Leading Digit Default 00 00H 0AH S5A Truncate Last Digit Default 00 00H 0AH...

Страница 35: ...ault T 20H 7EH T2A Verification OFF T3A Transmit Check Character OFF T4A ON T1B ON T3B ON T4B Truncate Leading Digit Default 00 00H 50H T5A Truncate Last Digit Default 00 00H 50H T6A Select Insertion...

Страница 36: ...ENDF 36 3 16 GS1 Code Option GS1 14 Reading OFF U1B Code ID Default U 20H 7EH UUA Application ID transmit OFF UAA 01 UAC ON U1A 01 UAB Symbol ID transmit OFF UDA ON UDB Transmit Check Character OFF U...

Страница 37: ...n SETF End Configuration ENDF 37 GS1 Limited Reading OFF U2B Code ID Default V 20H 7EH UVA Application ID transmit OFF UBA 01 UBC ON U2A 01 UBB Symbol ID transmit OFF UEA ON UEB Transmit Check Charact...

Страница 38: ...S1 Expanded Reading OFF U3B Code ID Default W 20H 7EH UWA Application ID transmit 01 Terminator MDD 01 MDB ON U3A OFF Terminator MDC 01 MDA FNC1 Transmit OFF M7A ON M7B Application ID Terminator Defau...

Страница 39: ...A APPENDIX A ASCII CODE...

Страница 40: ...1 SOH DC1 1 A Q a q 2 STX DC2 2 B R b r 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT E...

Страница 41: ...PENDIX C ASCII Table Under Function Off Function OFF 0 1 0 NUL DLE 1 SOH DC1 2 STX DC2 3 ETX DC3 4 EOT DC4 5 ENQ NAK 6 ACK SYN 7 BEL ETB 8 BS CAN 9 HT EM A LF SUB B VT ESC C FF FS D CR GS E SO RS F SI...

Страница 42: ...tion key Table Under Function on Function ON 0 1 0 NULL CTRL 1 UP F1 2 DOWN F2 3 LEFT F3 4 RIGHT F4 5 PAGE UP F5 6 PAGE DOWN F6 7 F7 8 BS F8 9 TAB F9 A F10 B HOME ESC C END F11 D ENTER F12 E INSERT AL...

Отзывы: