manualshive.com logo in svg
background image

DOCUMENT SCANNER

INSTRUCTIONS

PUB.CE-IE-986

0501AB0.5

CANON ELECTRONICS INC. 2001

PRINTED IN JAPAN

CANON ELECTRONICS INC.
1248, SHIMOKAGEMORI, CHICHIBU-SHI, SAITAMA 369-1892, JAPAN
CANON U.S.A. INC.
ONE CANON PLAZA, LAKE SUCCESS, N.Y.11042, U.S.A.
CANON CANADA INC.
6390 DIXIE ROAD, MISSISSAUGA, ONTARIO L5T 1P7, CANADA
CANON EUROPA N.V.
BOVENKERKERWEG 59-61, 1185XB AMSTELVEEN, THE NETHERLANDS
CANON LATIN AMERICA, INC.
6505, BLUE LAGOON DRIVE, SUITE 325 MIAMI, FLORIDA 33126 U.S.A.
CANON AUSTRALIA PTY. LTD.
1 THOMAS HOLT DRIVE, NORTH RYDE, SYDNEY. N.S.W, 2113. AUSTRALIA
CANON HONG KONG COMPANY LTD.
10/F., LIPPO SUN PLAZA, 28 CANTON ROAD, TSIMSHATSUI, KOWLOON, HONG KONG.

Содержание DR-5060F

Страница 1: ...DOCUMENT SCANNER INSTRUCTIONS...

Страница 2: ...ss A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environm...

Страница 3: ...Caution Take note of the following when using the scanner to make copies Reproducing money other forms of currency or negotiable securities is an offense and may be subject to criminal prosecution Re...

Страница 4: ...ry or damage to the equipment or loss of valuable data NOTE Read carefully to avoid damage to the equipment MEMO Read carefully memos indicate where you will find useful information in this manual Thi...

Страница 5: ...24 Handling the Camera Unit 25 Loading Film 25 Affixing the Index Label 28 Loading the Camera Unit in the DR 5060F 29 Removing the Camera Unit 30 Removing Film 31 Preparing for Paper Feeding and Eject...

Страница 6: ...6 Attaching the Intermediate Unit 67 Paper Feed Trouble 68 When the Scanned Image is Not Normal 70 When an Error Code is Displayed 71 About the Remaining Film Warning 73 Chapter 5 Daily Cleaning 75 Da...

Страница 7: ...onnect the ground cable to gas pipes or water pipes Doing so might cause fire Never attempt to disassemble or modify the unit Never use any type of flammable spray near the unit Before you clean the u...

Страница 8: ...so might expose or break the core leads damage the power cord and cause fire or electrical shock Keep the area around the power outlet clear of all obstacles so that you can disconnect the power cord...

Страница 9: ...n such places is unavoidable provide a curtain or similar object to shade the unit Places subject to dust and fumes Dust and cigarette fumes adversely affect the components inside the unit Places subj...

Страница 10: ...leg Do not tug the power cord When you remove the power cord grip it by the plug head Keep the area around the power outlet free of obstacles Carrying When you move the DR 5060F it should be held by...

Страница 11: ...chapter describes the features of the scanner what s in the box and the names and functions of parts on the scanner and the camera unit Features of DR 5060F 10 Packaging What s in the Box 11 Names an...

Страница 12: ...main unit This eliminates the need to operate the application each time that you load a document for example when you are scanning a large number of documents Skew detection This function automatical...

Страница 13: ...camera unit and microfilm are sold separately Contact your place of purchase or a Canon service department Backup FILM E F A Feeding Option New File Space Count Only Manual Auto Semi Auto Scanner DR 5...

Страница 14: ...jected onto this tray Upper unit open close button Operation panel This panel is for setting up scan density and other basic functions The number of scanned pages and error codes are also displayed he...

Страница 15: ...o this connector CAUTION To avoid overheating and causing a fire never block the air vents on the rear of this scanner Backup FILM E F A Feeding Option New File Space Count Only Manual Auto Semi Auto...

Страница 16: ...Settings P 52 Manual Thickness Adjustment Fixed Thickness Mode Double Feed Detection Imprinter Film Density Odometer Indication Page Address Indication File Address Indication Restore Memorized Settin...

Страница 17: ...y Pressing this key lights the lamp in the key and sets the Count Only mode In this mode document pages that are fed are neither scanned nor photographed They are only counted For details on this mode...

Страница 18: ...the key indicator to adjust the brightness Moving the indicator to the right increases the brightness and to the left decreases the brightness The brightness can be adjusted in 13 steps If you press t...

Страница 19: ...ng large size e g A3 11 x 17 in or thin documents This plate prevents such documents from becoming caught on the document eject tray Function key labels Function key labels Write the name of the funct...

Страница 20: ...the 1 24 camera unit 24X is used only the top side of originals is photographed in the simplex mode SIMPLEX When the 1 57 camera unit 57X is used both sides of originals are photographed simultaneous...

Страница 21: ...s chapter describes the preparations starting with connecting to a computer through to preparations for scanning System Requirements 20 Connecting to a Computer 21 Handling the Camera Unit 25 Preparin...

Страница 22: ...tion P 7 under Safety Precautions The driver may not function properly depending on the application you are using Select a computer operating environment and SCSI card to suit the driver application y...

Страница 23: ...uter to the scanner using the SCSI cable Two half pitch 50 pin SCSI connectors are located on the rear of the scanner Insert the SCSI cable from the computer into one of these connectors To connect an...

Страница 24: ...ing the settings of switches SW2 to SW4 Set unique SCSI IDs to any other built in SCSI devices or SCSI devices connected to the computer SCSI ID 0 1 2 3 4 5 6 7 SW2 ON ON ON ON OFF OFF OFF OFF SW3 ON...

Страница 25: ...CSI devices to OFF Terminator OFF Terminator ON CAUTION When this unit is connected as the last device of the daisy chain either set the terminator DIP switch ON or set the terminator DIP switch OFF a...

Страница 26: ...might cause fire or electrical shock Never grasp the plug when your hands are wet Never plug the unit into a multi plug power strip Never bundle or tie the power cord around itself or another object...

Страница 27: ...unit through to placing and removing the camera unit from this unit and removing film Loading Film 1 Press the release notch to open the camera unit s cover MEMO When you buy the camera unit the camer...

Страница 28: ...the number 2 written on the reel face up 4 Pass the film along the film path as shown in the figure below 5 Close the left cover taking care not to nip the film NOTE To prevent the film from being exp...

Страница 29: ...of the film into the take up reel with the number 1 written on the reel face up 7 Place the take up reel on the shaft 8 Turn the reel a few times in the direction of the arrow and make sure that the...

Страница 30: ...ining indicator first shows green when a new film loaded and begins to show red from the edge close to the lens as the film is consumed green red Affixing the Index Label Index labels are included amo...

Страница 31: ...to Scanner w e 3 Turn the lock lever to the LOCK position to lock the camera unit in place MEMO The film leader is fed automatically if you place a camera unit loaded with new film on this unit in the...

Страница 32: ...unit Backup FILM E F A Feeding Option New File Space Count Only Manual Auto Semi Auto Scanner 2 Lift up the front of the camera unit and gently remove it from the slot Backup FILM E F A Feeding Option...

Страница 33: ...Count Only Manual Auto Semi Auto 1 2 3 4 5 6 Space Trailer Backup Scanner NOTE Do not touch the lock lever with your hand while the trailer film is being fed MEMO Film cannot be removed as the releas...

Страница 34: ...without developing it the quality of valuable images may be impaired If the density of developed images is unsuitable adjust the density of the film to be photographed See Function Key Settings P 52 I...

Страница 35: ...t guide labels as aids for adjustment of the document guide Affix these guide labels on the document tray as shown in the figure Preparing the Document Tray Extension and Document Eject Tray Extension...

Страница 36: ...ull out the stopper to prevent ejected documents from flying out of the document eject tray extension 1 Pick up the document eject tray extension 1 from the center of the document eject tray 2 Draw ou...

Страница 37: ...ejected 1 Pick up the document eject tray extension 1 from the center of the document eject tray 2 Install the document eject support plate Install so that the protrusions on the document eject suppo...

Страница 38: ...Feed Adjustment Use the paper feed adjustment lever to adjust paper feed in the following instances when feed errors occur due to friction when scanning documents with a slippery surface when scanning...

Страница 39: ...ation mode of this unit is set to the Back up mode or Filmer Only mode without a camera unit placed on this unit Either place a camera unit loaded with film or change to the Scanner Only mode NOTE If...

Страница 40: ...Clear all checkmarks and then click Next 4 Click Next 5 Click Finish If Add New Hardware Wizard is displayed Windows Me select Automatic search for a better driver Recommended then click Next and then...

Страница 41: ...ter 3 Preparing Documents This chapter describes precautions regarding documents that can be handled on this scanner and document feed and scanning operations About Operation Modes 40 About Documents...

Страница 42: ...You can check and set the scanner s operation mode by the Backup and Count Only keys on the operation panel A FILM E F Feeding Option New File Count Only Manual Auto Semi Auto 1 2 3 4 5 6 Space Traile...

Страница 43: ...or which the paper jam occurred Count Only key lit Count Only mode In this mode the DR 5060F counts the number of documents without scanning them 1 Press the Count Only key on the operation panel of t...

Страница 44: ...e document may transfer to and stain the scanning rollers Before you scan these kind of documents make a copy on a copier and then scan the copy If you have scanned a document written in pencil or som...

Страница 45: ...their top edges are inserted as far as possible into the scanner A Feeding Option Manual Auto Semi Auto Do not load documents beyond the mark on the document tray Doing so might cause a paper jam As...

Страница 46: ...eding option Feeding Option key Set the feeding operation for the document See Selecting the Feeding Option P 45 Setting the function keys Function keys Use settings or functions pre stored to functio...

Страница 47: ...ed document has finished being scanned scanning is continued by pressing the Start key Auto In the Backup mode or Scanner Only mode scanning is automatically started by placing a document on the docum...

Страница 48: ...ion 5 The document tray rises and scanning begins The document tray is lowered when scanning of all pages in the document ends CAUTION If the document tray does not rise and you hear a clicking sound...

Страница 49: ...changes color from red to green 5 Press the Start key 6 The document tray rises and scanning begins The document tray is lowered when scanning of all pages in the document ends CAUTION If the documen...

Страница 50: ...ption key on the operation panel to light Auto lamp set the paper guide for the width of the document you are going to scan 2 Remove any pages from the document tray and press the Feeding Option key t...

Страница 51: ...o start scanning If the sensor is obstructed after start of scanning is instructed the DR 5060F mistakenly judges that a document has been loaded and the document tray automatically starts to move So...

Страница 52: ...paper guide for the width of the document you are going to scan A Feeding Option Manual Auto Semi Auto NOTE If Feeding Option is set to Manual in the Filmer Only mode scanning is started once the sens...

Страница 53: ...IN Driver Instructions or Scanning Utility 5060 Instructions 4 Load one sheet on the document tray face up with its top edge inserted into the scanner The document is scanned 5 Insert the document one...

Страница 54: ...AIN Driver Instructions or Scanning Utility 5060 Instructions Manual Thickness Adjustment See P 53 Fixed Thickness Mode See P 54 Double Feed Detection See P 54 Imprinter See P 55 Film Density See P 55...

Страница 55: ...one sheet from the document to be scanned on the document tray and press the Start key This scans the document and the paper thickness is displayed on the brightness indicator MEMO The paper thickness...

Страница 56: ...feed detection press the key to which double feed detection is registered to turn the lamp OFF NOTE A double feed error occurs when a stack of different size or thickness originals is fed Be sure to...

Страница 57: ...on key to which page address indication is registered the function key lamp blinks and the counter display indicates P This display then changes to indicate the page address of the currently loaded ca...

Страница 58: ...ide width default Skew detection setting Sets detection of skew when the document has skewed U3 0 Do not detect document skew default U3 1 Detect document skew and stop document feed U3 2 Detect docum...

Страница 59: ...00 mm 19 5 x 117 in U12 default 1500 mm 58 5 in Trailer setting Sets the trailer film feed amount Set in 100 mm 3 9 in increments within the range 500 mm to 3000 mm 19 5 x 117 in U13 default 1500 mm 5...

Страница 60: ...and returns the counter display to the counter display When the final letter of the user mode setting is A Scanner 1 Hold down A key for at least five seconds The A key blinks and the user mode appea...

Страница 61: ...uses of trouble that may occur with the DR 5060F and how to remedy the problem When the Scanner is Not Recognized 60 Removing Paper Jams 61 Paper Feed Trouble 68 When the Scanned Image is Not Normal 7...

Страница 62: ...Remedy Set the SCSI ID for each SCSI device to a unique number See Setting the SCSI ID and Terminator P 22 Cause The terminator is not correctly connected Remedy Connect the terminator to the last SC...

Страница 63: ...nip your fingers NOTE If a system error or paper jam stops feeding of the document during scanning clear the paper jam and then check that the image of the last ejected page of the document is correc...

Страница 64: ...C01 appears on the display 4 Remove the jammed paper from the paper eject section 5 Press the upper unit down firmly on both sides to close it If you press the upper unit down on only one side the opp...

Страница 65: ...ay extension if it is open 3 Press the open close button and lift up the upper unit Lift up the upper unit gently until it comes to a stop Backup FILM E F A Feeding Option New File Space Count Only Ma...

Страница 66: ...Auto Semi Auto 6 Remove the jammed paper from the feed section tion File Manual Auto Semi Auto 7 To close the feed unit push the feed unit inwards as far as possible and then release the feed unit Wh...

Страница 67: ...Backup FILM E F A Feeding Option New File Space Count Only Manual Auto Semi Auto Scanner 10 Press the upper unit down firmly on both sides to close it If you press the upper unit down on only one side...

Страница 68: ...h as checks are jammed in the intermediate unit follow the procedure below to remove the unit and remove the jammed paper 1 Slide the intermediate unit upwards 2 Pull down the intermediate unit toward...

Страница 69: ...1 Hold the intermediate unit at an angle and hook the notches on both sides onto the lower pins 2 Push in the intermediate unit as far as possible with it raised slightly off the pins The intermediate...

Страница 70: ...r worn rollers inside the scanner may cause paper jams Clean rollers if dirty See Cleaning the Scanning Glasses and Rollers P 77 Worn rollers must be replaced Contact a Canon service department Condit...

Страница 71: ...a dark background If this error occurs turn skew detection OFF and scan the document again Or make a copy of the document on different paper provide a wider margin around the document or lighten the b...

Страница 72: ...tion does not run correctly Remedy If the document cannot be scanned correctly even if the scan conditions are adjusted a probable cause is that the driver or the application is not functioning correc...

Страница 73: ...t be repaired by a service engineer Turn the power OFF contact the place of purchase or a Canon service department and notify them of the error code Error code F01 Cause The camera unit is not inserte...

Страница 74: ...hen the number of sheets is counted Press the Stop key to reset the counter to the set number of document sheets Check the number of sheets to see if all document sheets have been counted and scan the...

Страница 75: ...s and a buzzer sounds to notify the operator that the scanner is about to run of out film When the remaining film warning is displayed remove the camera unit and replace with new film MEMO When scanni...

Страница 76: ...74...

Страница 77: ...75 Daily Cleaning 5 Chapter 5 Daily Cleaning This chapter describes daily cleaning of the scanner Daily Cleaning 76...

Страница 78: ...Never clean the DR 5060F with any kind of volatile solution such as alcohol benzene and paint thinner Doing so might cause fire and electrical shock or cause the exterior to disfigure or discolor Nev...

Страница 79: ...support plate on the document eject tray if it is installed Close the document eject tray extension if it is open 3 Lift up the upper unit Backup FILM E F A Feeding Option New File Space Count Only Ma...

Страница 80: ...before wiping the rollers in the intermediate unit See Removing the Intermediate Unit P 66 The drive rollers indicated in the figure below cannot be rotated by hand If dirty drive rollers are causing...

Страница 81: ...directly on the scanning glasses The spray could penetrate below the glass and contaminate the internal light source and lenses 8 Wipe the rollers with a firmly wrung cloth moistened with water or mi...

Страница 82: ...inwards as far as possible and then release the upper unit When you release the feed unit it begins to slowly fall down Do not apply unnecessary force to push the feed unit down Doing so might damage...

Страница 83: ...ide the opposite side will not be fully closed Make sure that you hear it click into place MEMO The error code C01 will appear when the scanner is turned ON if both the upper unit and the feed unit ar...

Страница 84: ...Take care not to scratch the lens when wiping it Remove any dirt from the capstan roller with a firmly wrung cloth moistened slightly with water or mild detergent while rotating the roller Power Cord...

Страница 85: ...ning 5 Daily Cleaning Imprinter Guide Plate Ink adhering to the holes on the guide plate on the inside sometimes cause documents to become dirty when the imprinter is used Clean these holes with a cot...

Страница 86: ...in Duplex 200 x 200 dpi 50 51 sheets min Gray scale Simplex 200 x 200 dpi 30 31 sheets min 300 x 300 dpi 18 18 sheets min Duplex 200 x 200 dpi 22 22 sheets min 300 x 300 dpi 12 12 sheets min Filmer On...

Страница 87: ...his endorser stamps an 8 digit number and any specified characters on the rear side of the document after it is scanned Imprinter 5000 Attached inside the main unit this imprinter prints characters su...

Страница 88: ...ment detection setting 56 Document eject support plate 17 35 Document eject tray extension 34 Document eject tray 12 Document eject tray extension stopper 12 Document guide 12 Document guide labels 17...

Страница 89: ...Paper jam in the paper eject section 61 Paper jams 61 Patch code 85 Power cord 82 Power cord connector 13 Power supply 8 Power switch 12 37 R Rear view 13 Remaining film indicator 14 Remote 45 46 Rem...

Страница 90: ...88 Index U Upper unit 12 Upper unit open close button 12 User mode setting 44 58...

Страница 91: ......

Страница 92: ...A CANON CANADA INC 6390 DIXIE ROAD MISSISSAUGA ONTARIO L5T 1P7 CANADA CANON EUROPA N V BOVENKERKERWEG 59 61 1185XB AMSTELVEEN THE NETHERLANDS CANON LATIN AMERICA INC 6505 BLUE LAGOON DRIVE SUITE 325...

Отзывы: