SPECIAL SAFETY INSTRUCTIONS
Keep water away from any electrical parts of the power tool and from persons in the working area.
Never use the machine without a PRCD.
1
Be operated using an PRCD.
The machine may only operated using a PRCD with a max. rated fault current of 10 mA.
2
Use gloves.
Use special safety glove all time to reduce personal injuries.
3
Wear rubber boots
(for insulation) when performing cleaning work.
3
Use hearing protection.
Noise level when working can exceed 88 dB (A). Use ear protection all time!
4
Wear eye protection.
When working with power tools there is a risk of floating soil. Wear eye protection to reduce
eye injuries.
5
The drain cable must be removed completely
from the holding cage before machine is turned on.
6
Before inserting the plug into the electrical socket
, make absolutely sure that the pipe cleaning machine is switched
to 0 or
OFF
.
7
To prevent damage,
use this machine and its accessories only to clean waste water pipes
—
never chimneys, wells,
etc.
8
To prevent damage to the pipes
or pipe bends, do not modify tools by sharpening them, etc.
9
Use a camera system
to spot the cause of the pipe clog.
DESCRIPTION (FIG.1 et 2)
1 Guide hose
2 Protecting cap
3 Clutch and transport handle
4 Drain cable
5 Tool
6 On / Off switch
7 Power cable
8 PRCD
9 TEST switch
10 Indicator light
11 RESET switch
12 Male connector
13 Female connector
14 Decoupling key
TECHNICAL DATA
Voltage :
......................................................................................................................................................................
230 V, 50 Hz
Rated power cons. :
...........................................................................................................................................................
750 W
Operating speed :
...........................................................................................................................................................
690 rpm
Working range :
...........................................................................................................................................
Ø 50
–
Ø 150 mm
Max. working length :
..........................................................................................................................................................
70 m
Weight :
.......................................................................................................................................................................................
26 kg
Typical weighted acceleration in the hand-arm area :
.........................................................................
< 2,5 m/s
2
Sound pressure level (L
pA
)
.......................................................................................................
72 dB (A) | K
pA
3 dB (A)
Sound power level (L
WA
)
..........................................................................................................
85 dB (A) | K
WA
3 dB (A)
Protection class :
......................................................................................................................................................................
IP44
Noise level when working can exceed 88 dB (A). Use ear protection!
The typical weighted acceleration in the hand-arm area can exceed the declared value of 2,5 m/s². If you observe
increased vibrations stop working with power tool. Check the machine for dynamic unbalance.
WARNING:
The drain cleaning machines are only designed for short term operation and may therefore only be
used for maximum continuous of 15 minutes (15 minutes work / 45 minutes break)