1.   For shipping purposes, 

the UV lamp and sleeve 

are shipped in a separate 

cardboard box. Carefully 

remove the UV lamp from 

the shipping box being 

careful not to touch the 

“glass” portion with your 

fingers. Insert the UV lamp 

into the quartz sleeve and 

chamber making sure the 

connection end is inserted 

last. Mount the disinfection system to the wall or cabinet.

2.   If the disinfection system is to be hard plumbed, make sure you leave enough 

clearance in front of the lamp connector to facilitate lamp service (a length 

equal to the length of the unit should suffice).

3.   This system is designed to install on the main cold water line. Install the 

disinfection system before any branch lines. Mount the system to the wall 

using the two mounting holes in the back of the disinfection system with 

appropriate fastening devices. Various connection methods can be used to 

connect the water source to the disinfection system, however union type 

connectors are recommended. 

4.   Prior to connecting the power source, check all connections to ensure that 

they are indeed secure, turn on water supply and check for any  leaks. If 

satisfied that there are no leaks, proceed with the following  steps.

5.   Push lamp plug onto end of lamp. 
6.   Attach ground (green/yellow) and relief (red) wires from lamp. Plug to the 

ground lug on the chamber. Secure both wires with locking screw provided.

7.    The power source provided with your disinfection system must be located 

within (5) feet of an electrical outlet. DO NOT USE AN OUTLET THAT CAN 

BE SWITCHED OFF (IE. A WASTE DISPOSAL OUTLET). 

5

1

2

Insert Lamp/
sleeve assembly 
and screw into 
chamber.

Caution: Over 
tightening will 
break the sleeve. 

Note:  If ballast enters alarm condition, power must be unplugged for several seconds to 

allow ballast to reset.

Note:  As the system requires time to reach its full operating capacity,please allow the 

disinfection system to operate 3 - 5 minutes prior to using the water from the unit. In 
addition, to clear any air or debris from the system, open the faucet and allow water to 
run through the disinfection system for 2 - 3 minutes.

6

SLEEVE CLEANING AND LAMP REPLACEMENT

1.   Turn off the shut-off valve situated by the inlet of the drinking water system.
2.   Open a tap downstream of the UV system to release pressure. 

Then, close this tap.

3.   Turn off the shut-off valve situated by the outlet of the drinking water system.
4.   Disconnect the power.
5.   Let the system cool down for 10 minutes.
6.   Squeeze sides opposite of tabs to remove cover. The strain relief wire should 

remain connected.

1

2

7.    Hold the sleeve 

bolt to remove 

lamp/sleeve 

assembly (first 

twist, then pull).

8.    

For sleeve cleaning only:

 

Skip to step 14.

 

Note: Sleeve must be replaced if it 

cannot be completely cleaned or if 

it appears scratched or cracked.

 

For lamp or sleeve replacement: 

Clean sleeve and follow steps 

10-13.

9.    

Sleeve 
bolt

Lamp 
tab

1

10.     Remove o-rings and sleeve bolt 

from sleeve.

Содержание UVMax DWS11-A

Страница 1: ...r UV system is designed to provide you with years of trouble free operation with minimal maintenance required 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Can...

Страница 2: ...has been confirmed Hot chamber Allow UV Lamps UV Chamber to cool for a minimum of 10 minutes before handling Cut or ingestion Ensure the quartz sleeve or lamp is not broken cracked or damaged in any w...

Страница 3: ...ater Chemistry 4 Installing Your UV Disinfection System 4 5 Operating Maintenance Instructions 6 7 Manufacturer s Warranty 8 9 Specifications 10 Caution Protective Ground Electrical Warning Fragile Ey...

Страница 4: ...125 PSI 862 kPa Minimum operating pressure 4 PSI 27 5 kPa Maximum ambient air temperature 122 0 F 500 C Minimum ambient air temperature 320 F 00 C Maximum humidity 100 Maximum hardness 120 ppm 7 grain...

Страница 5: ...sis Replacement lamps and sleeves provided under warranty will be sent to your TrojanUVMax dealer This warranty on lamps and sleeves does not include shipping and handling charges which will be collec...

Страница 6: ...VMax products Ten Year Limited Warranty for TrojanUVMax UV Chamber VIQUA warrants the UV chamber on the TrojanUVMax products to be free from defects in material and workmanship for a period of ten 10...

Страница 7: ...ast enclosure causing a potential for ballast failure For safety purposes the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor...

Страница 8: ...crew provided 7 The power source provided with your disinfection system must be located within 5 feet of an electrical outlet DO NOT USE AN OUTLET THAT CAN BE SWITCHED OFF IE A WASTE DISPOSAL OUTLET 5...

Отзывы: