Viqua UVMax DWS11-A Скачать руководство пользователя страница 5

2

WARNING

 - To guard against injury, basic safety precautions 

should be observed, including the following:

1. 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

2.  

DANGER

 - o avoid possible electric shock, special care should 

be taken since water is employed in the use of this system. 

Unless a situation is encountered that is explicitly addressed by 

the provided maintenance and troubleshooting sections, do not 

attempt repairs yourself; refer to an authorized service facility.

3.   CAUTION - Do not operate with broken or faulty parts as this 

may result in exposure to ultraviolet radiation. Contact supplier 

for replacement parts.

4.   Do not operate the system if it has a damaged cord or plug, or 

if it is malfunctioning or if it has been dropped or damaged in 

any manner.

5.   Always unplug the system, release water pressure before 

servicing or cleaning. Never yank cord to remove from outlet; 

grasp the wall plug and pull to disconnect.

6.   Do not use the system for other than intended use. The use 

of attachments not recommended or sold by the manufacturer 

may cause an unsafe condition.

7.   To prevent risk of electrical shock, connect this system only to 

a properly grounded, grounding-type power supply receptacle 

that is protected by a Ground Fault Circuit Interrupter (GFCI). 

Inspect performance of GFCI as per manufacturer’s suggested 

maintenance schedule. If an extension cord is used, ensure it 

is of a sufficient rating and accepts the plug from this system; 

never use an adapter. 

8.   Visually inspect this system prior to installation. If the quartz 

sleeve or lamp is broken, cracked or damaged in any way, do 

not use. Contact the supplier for replacement parts.

9.  Keep all connections dry and off the ground. Do not touch plug 

with wet hands.

10. The light emitted by the lamp will cause serious eye damage 

and burn unprotected skin. Do not plug system into an 

electrical outlet without first properly securing the lamp into the 

chamber. Unplug the system prior to removing the lamp from 

the chamber. 

11. If the UV system malfunctions or fails, water must be boiled 

prior to consumption until the UV system is operational and the 

water lines have been shocked. System failure is indicated by 

the system’s audible and visual alarms or the absence of any 

indicator light. 

SAFETY INSTRUCTIONS

The warranty period for lamps and sleeves may be verified using date codes in addition to purchase 
receipts and VIQUA’s database of registered owners. VIQUA will advise you whether the defective 
item needs to be returned to a VIQUA dealer for failure analysis. Replacement lamps and sleeves 
provided under warranty will be sent to your TrojanUVMax™ dealer.

This warranty on lamps and sleeves does not include shipping and handling charges which will be 
collected from you by the dealer. Parts replaced under this one (1) year warranty will be covered 
under warranty to the end of the original one (1) year warranty period. This warranty is also subject 
to the conditions and limitations outlined under the heading “General Conditions and Limitations” 
below.

Warranty for Replacement Lamps and Parts

VIQUA warrants replacement lamps, purchased for annual routine maintenance, and other parts 
purchased to repair product components that are no longer covered by the original warranty, to be 
free from defects in material and workmanship for a period of three (3) months from the date of 
purchase. During this time, we will repair or replace, at its option, a defective replacement lamp or 
part free of charge except for shipping and handling charges.

The warranty period on replacement lamps and parts will be verified using date codes and/or 
purchase receipts. VIQUA will advise you whether the defective item needs to be returned to your 
dealer for failure analysis. Replacement lamps and parts provided under warranty will be sent to your 
dealer.

General Conditions and Limitations

None of the above warranties cover damage caused by improper use or maintenance, accidents, 
acts of God or minor scratches or imperfections that do not materially impair the operation of the 
product. The warranties also do not cover products that are not installed as outlined in the applicable 
Owner’s Manual.

The limited warranties described above are the only warranties applicable to the TrojanUVMax™ 
products listed. These limited warranties outline the exclusive remedy for all claims based on a 
failure of or defect in any of these products, whether the claim is based on contract, tort (including 
negligence), strict liability or otherwise. These warranties are in lieu of all other warranties whether 
written, oral, implied or statutory. Without limitation, no warranty of merchantability or of fitness for 
a particular purpose shall apply to any of these products.

VIQUA - a Trojan Technologies Company does not assume any liability for personal injury or property 
damage caused by the use or misuse of any of the above products. VIQUA shall not in any event be 
liable for special, incidental, indirect or consequential damages. VIQUA’s liability shall, in all instances, 
be limited to repair or replacement of the defective product or part and this liability will terminate 
upon expiration of the applicable warranty period.

9

WARNING

 -

 

Always shut-off water flow and release water pressure 

before servicing.

Содержание UVMax DWS11-A

Страница 1: ...r UV system is designed to provide you with years of trouble free operation with minimal maintenance required 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Can...

Страница 2: ...has been confirmed Hot chamber Allow UV Lamps UV Chamber to cool for a minimum of 10 minutes before handling Cut or ingestion Ensure the quartz sleeve or lamp is not broken cracked or damaged in any w...

Страница 3: ...ater Chemistry 4 Installing Your UV Disinfection System 4 5 Operating Maintenance Instructions 6 7 Manufacturer s Warranty 8 9 Specifications 10 Caution Protective Ground Electrical Warning Fragile Ey...

Страница 4: ...125 PSI 862 kPa Minimum operating pressure 4 PSI 27 5 kPa Maximum ambient air temperature 122 0 F 500 C Minimum ambient air temperature 320 F 00 C Maximum humidity 100 Maximum hardness 120 ppm 7 grain...

Страница 5: ...sis Replacement lamps and sleeves provided under warranty will be sent to your TrojanUVMax dealer This warranty on lamps and sleeves does not include shipping and handling charges which will be collec...

Страница 6: ...VMax products Ten Year Limited Warranty for TrojanUVMax UV Chamber VIQUA warrants the UV chamber on the TrojanUVMax products to be free from defects in material and workmanship for a period of ten 10...

Страница 7: ...ast enclosure causing a potential for ballast failure For safety purposes the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor...

Страница 8: ...crew provided 7 The power source provided with your disinfection system must be located within 5 feet of an electrical outlet DO NOT USE AN OUTLET THAT CAN BE SWITCHED OFF IE A WASTE DISPOSAL OUTLET 5...