Viqua UVMax DWS11-A Скачать руководство пользователя страница 4

1

COMPONENTS

Power supply

(includes Safety cap, 

Lamp cord)

650414 (120 V) 

650415 (230 V)

Safety cap

603000

Lamp cord

 --

Power cord

602636 (120V) 

602637 (230V)

Lamp

(includes O-rings)

602803

O-ring

--

Sleeve bolt

602665

Sleeve

(includes O-rings)

602730

Sediment Filter

AWP110

Carbon Filter

C-01

1

2

3

Part

Part Number

Components

4

5

6

7

8

For replacement components please contact your installer or contact VIQUA directly 
for a referral: 1 800 265 7246 (North America), 519 763 1032, or [email protected].

2

1

3

4

5

6

7

8

6

SPECIFICATIONS

Operating Parameters

Maximum operating pressure

125 PSI (862 kPa)

Minimum operating pressure

 4 PSI (27.5 kPa)

Maximum ambient air temperature

122 

0

F  (50

0

C) 

Minimum ambient air temperature

32

0

F  (0

0

C) 

Maximum humidity

100%

Maximum hardness

120 ppm 
(7 grains per gallon)

Maximum iron

0.3 ppm

Minimum UVT

75%

Flow Rates*

Maximum rated flow at dose of 16 mJ/cm

2

3 GPM (11 LPM)

Maximum rated flow at dose of 30 mJ/cm

2

1.5 GPM (4 LPM)

Maximum rated flow at dose of 40 mJ/cm

2

1 GPM (4 LPM)

Electrical

Voltage

120-230V AC

Frequency

50-60 Hz

Max. current

0.5 Amp

Max. power consumption

22 Watts

Lamp power

14 Watts

Other

UV Chamber Material

304 SST

Inlet/Outlet

3/8" NPT (female)

Other

Rated service life of lamp

1 year

Installation Kit

Yes

Visual “Power On”

Yes

Audible Lamp Failure

Yes

Specifications

*Flow rates shown are at 85% UVT.

10

Содержание UVMax DWS11-A

Страница 1: ...r UV system is designed to provide you with years of trouble free operation with minimal maintenance required 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Can...

Страница 2: ...has been confirmed Hot chamber Allow UV Lamps UV Chamber to cool for a minimum of 10 minutes before handling Cut or ingestion Ensure the quartz sleeve or lamp is not broken cracked or damaged in any w...

Страница 3: ...ater Chemistry 4 Installing Your UV Disinfection System 4 5 Operating Maintenance Instructions 6 7 Manufacturer s Warranty 8 9 Specifications 10 Caution Protective Ground Electrical Warning Fragile Ey...

Страница 4: ...125 PSI 862 kPa Minimum operating pressure 4 PSI 27 5 kPa Maximum ambient air temperature 122 0 F 500 C Minimum ambient air temperature 320 F 00 C Maximum humidity 100 Maximum hardness 120 ppm 7 grain...

Страница 5: ...sis Replacement lamps and sleeves provided under warranty will be sent to your TrojanUVMax dealer This warranty on lamps and sleeves does not include shipping and handling charges which will be collec...

Страница 6: ...VMax products Ten Year Limited Warranty for TrojanUVMax UV Chamber VIQUA warrants the UV chamber on the TrojanUVMax products to be free from defects in material and workmanship for a period of ten 10...

Страница 7: ...ast enclosure causing a potential for ballast failure For safety purposes the disinfection system should be connected to a ground fault interrupt circuit The disinfection system is intended for indoor...

Страница 8: ...crew provided 7 The power source provided with your disinfection system must be located within 5 feet of an electrical outlet DO NOT USE AN OUTLET THAT CAN BE SWITCHED OFF IE A WASTE DISPOSAL OUTLET 5...

Отзывы: