1.3 Water Chemistry

Water quality is extremely important for the optimum performance of your UV system. The following levels are 

recommended for installation:

* Where total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve is cleaned 

periodically. If total hardness exceeds 7 gpg, the water should be softened. If your water chemistry contains levels in excess 

of those mentioned above, proper pre-treatment is recommended to correct these water problems prior to the installation of 

your UV system. These water quality parameters can be tested by your local dealer, or by most private analytical 

laboratories. 

Proper pre-treatment is essential for the UV system to operate as intended

.

WA R N I N G

  •

During extended periods of no water flow, the water in your chamber can become very hot (Approx. 60 °C) and potentially lead to scalding. It is 
recommended to run your water until this hot water has been purged from your chamber. Do not allow water to contact your skin during this time. 
To eliminate this condition, a temperature management valve can be installed at the outlet of your UV system.

  •

Do not pass water through the UV system for a minimum of 5 minutes after applying power (including after power interruptions) to avoid passing 
under-treated water that may, in rare instances, pose health hazards.

  •

This system contains a UV Lamp. Do not operate the UV Lamp when it is removed from the chamber. Unintended use or damage of the system 
may result in the exposure of dangerous UV radiation. UV radiation may, even in little doses, cause harm to the eyes and skin.

  •

Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void 
the manufacturer's warranty.

WARNING:

 This product can expose you to chemicals including phthalates, which is known to the state of California to cause cancer, and mercury, 

which is known to the State of California to cause birth defects or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov

.

C A U T I O N

Failure to follow these instructions could result in minor or moderate injury.

  •

Carefully examine the UV system after installation. It should not be plugged in if there is water on parts not intended to be wet such as, the 
controller or lamp connector.

  •

Due to thermal expansion concerns and potential material degradation due to UV exposure, it is recommended to use metal fittings and at least 
10" of copper pipe on the outlet of your UV chamber.

  •

Hg EXPOSURE

: The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes 

and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for 
the removal and disposal of mercury waste.

N O T I C E

  •

The UV lamp inside the UV system is rated at an effective life of approximately 9000 hours. To ensure continuous protection, replace the UV lamp 
annually.

  •

The UV system is not to be used or played with by children. Persons with reduced physical, sensory or mental capabilities, or lack of experience 
and knowledge, are also not to handle the UV system unless they have been given supervision or instruction. 

  •

This system is intended to be permanently connected to the water lines.

  •

This system is not intended to be used in or above water or outdoors or used in swimming pools when persons are in the pool.

  •

EXTENSION CORDS

: If an extension cord is necessary, use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole cord 

connectors that accept the plug from this system. Use only extension cords that are intended for outdoor use. Use only extension cords having an 
electrical rating not less than the rating of the system. A cord rated for less amperes or watts than this system rating may overheat. Exercise 
caution when arranging the cord so that it will not be tripped over or pulled. DO NOT use damaged extension cords. Examine extension cord 
before using and replace if damaged. DO NOT abuse extension cord. Keep extension cord away from heat and sharp edges. Always disconnect 
the extension cord from the receptacle before disconnecting this system from the extension cord. Never yank cord to pull plug from outlet. Always 
grasp the plug and pull to disconnect.

  •

If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.

  •

SYSTEM PROTECTION:

 To protect your Controller, a UL1449 certified (or equivalent) transient voltage surge suppressor is strongly 

recommended.

  •

The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations (CFR) requirements including, Title 21, 
Chapter 1, Subchapter J, Radiological Health.

  •

Read and understand the Owner’s Manual before operating and performing any maintenance on this equipment.

Water Quality and Minerals

Level

Iron

< 0.3 ppm (0.3 mg/L)

Hardness*

< 7 gpg (120 mg/L)

Turbidity

< 1 NTU

Manganese

< 0.05 ppm (0.05 mg/L)

Tannins

< 0.1 ppm (0.1 mg/L)

UV Transmittance

> 75% (call factory for recommendations on applications where UVT < 75%)

UV

Hg

Содержание IHS22-E4

Страница 1: ...Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Model IHS22 E4 Owner s...

Страница 2: ...d VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV equipment An increasing number of calls to VIQUA Technical Suppo...

Страница 3: ...t Interrupter GFCI This symbol indicates there is a potential for VERY hot water when flow is started DANGER Failure to follow these instructions will result in serious injury or death Electric Shock...

Страница 4: ...at least 10 of copper pipe on the outlet of your UV chamber Hg EXPOSURE The UV lamp contains mercury If the lamp breaks then avoid inhalation or ingestion of the debris and avoid exposure to eyes and...

Страница 5: ...230V IHS22 E4 2 260013 Australian IHS22 E4 2A 260012 UK IHS22 E4 2B 7 Controller includes Controller mounting bracket Lamp connector 650733R 001 Used on all systems 8 Controller mounting bracket 9 La...

Страница 6: ...iqua website WWW VIQUA COM LCD 2 1 Dimensions and Layout Figure 2 Model IHS22 E4 Controller Components Figure 3 System Dimension and Layout 100 240 VAC 50 60Hz 1 2A SERIAL 000001 PART IHS22 E4 REPLACE...

Страница 7: ...ystem Provides filtration and UV 6 Controller Powers and controls the UV lamp and other devices Provides human interface displaying information and allowing control inputs such as muting the audible a...

Страница 8: ...ws CAUTION The sump housings will be heavy 5 Ensure quartz sleeve is properly centered in the chamber 6 2 1 Place sleeve bolt onto the quartz sleeve carefully push down and hand tighten onto chamber 7...

Страница 9: ...d pour 2 cups of household bleach solution into the sump housings Note DO NOT use Hydrogen Peroxide 7 1 1 2 2 Reinstall the housings 8 0 30 15 45 30 mins Open all faucets and turn on the cold water su...

Страница 10: ...Buttons and Display Feature Description Function A Status Screen Displays the following Lamp life days Product information Product support UV level status Active alarms B Pushbutton 1 Scroll Mute 24Hr...

Страница 11: ...elect to enter the model preferred This ensures the correct replacement parts are displayed in the Info screen Product Registration Reminds USER to register their product for product updates and lamp...

Страница 12: ...ESET screen Lamp Replacement RESET Press and hold button for 5 seconds until you here an audible beep Your Lamp Life Days is now reset to 365 days Lamp life 30 Days Remaining Status Info Support Lamp...

Страница 13: ...Lamp Failure Scroll V V 1 UV Lamp Ignition Fault UV Lamp Run Fault 2 Unplug UV system from main power supply 3 Check for secure lamp connection 4 Restore power to UV system Lamp Failure Scroll V V 5 I...

Страница 14: ...or contact information select support screen Status Info Support Scroll V V Controller Failure Mute 1 Unplug UV system from main power supply 2 Allow 30 seconds for unit to fully power down 3 Restore...

Страница 15: ...display will be blank and a solid audible tone will sound Replace Controller Sensor Signal 1 Sensor signal is outside of proper operating parameters 2 Replace UV sensor Failure 3 See Info screen for r...

Страница 16: ...E4 650718 SYS E4 PROFESSIONAL 230VAC E4 660040 R SYS E4 V NSF Class B 120VAC E4 V 650683 SYS E4 PROFESSIONAL 120VAC E4 650719 SYS E4 PROFESSIONAL 230VAC E4 660043 R SYS E4 V NSF Class B 120VAC E4 V 6...

Страница 17: ...Failure 3 Lamp Failure 4 UV Sensor Failure Figure 6 Dry Contact Connections Dry Contact Connection Logic Chart Output Connection UV System Running Normally No Major Alarms UV System Is In a Major Ala...

Страница 18: ...l this hot water has been purged from your chamber Do not allow water to contact your skin during this time To eliminate this condition a temperature management valve can be installed at the outlet of...

Страница 19: ...contaminated after the UV system it is necessary to complete the cleaning procedure Refer to Section 3 2 1 2 1 Unscrew the sleeve bolt and carefully remove it from the top of the chamber Note Sleeve...

Страница 20: ...aker repeatedly trips Connection between lamp and lamp plug is wet Clean and dry lamp pins and lamp plug check unit for leaks or condensation Short circuit in the electrical assembly Replace controlle...

Страница 21: ...talled Remove the sump wipe the O ring and threads clean ensure the O ring is fitted properly then reinstall Filter cartridge not centered Remove sump check for cartridge damage re assemble ensuring c...

Страница 22: ...ardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During this time VIQUA will repair or replace at its option any defective...

Страница 23: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Отзывы: