INS
TALLA
TION
W
ARRANT
Y
MAINTENANCE
OPERA
TION
O
VER
VIEW
Indicator lights
Option not available on
this system
Option not available on
this system
Option not available on
this system
Option not available on
this system
Lamp operating normally
Warning; lamp will require
replacement shortly
Lamp disconnected; unplug system,
reconnect lamp and plug-in system again
Lamp failure; replace lamp
Lamp inactive due to power
supply failure
Power supply operating
normally
Air temperature around
system is too warm
Power supply failure; replace power
supply
Power supply inactive due
to lamp failure
Yellow
Flashing red
Solid red
Green
Indicator lights only indicate a problem with the component when flashing red.
The table below is a list of
possible
causes and solutions. Before replacing parts, please contact VIQUA
Technical Assistance for any new troubleshooting techniques. 1-800-265-5774
Lamp timer
display
Counts down from 365 days to show time for annual lamp replacement.
Lamp timer
reset
After installing a new lamp, press and hold for five seconds to reset Lamp timer to
365.
Mute
Press to silence audible alarm.
When the alarm is due to the lamp's age, the mute button will silence the audible
alarm for 7 days; this may be repeated up to a maximum of 4 times. After that, the
button will silence for only 24 hours.
When the alarm is due to any other issue, the mute button will silence the audible
alarm for 24 hours.
1
2
3
B
A
C
CONTROL PANEL
Buttons and Display
1
2
3
B
A
C
13