Operation
10
3.2.6 Error Message
If the word “ERROR” and a number are alternately flashing on the display record the number and contact your dealer for
help. This indicates that the control valve was not able to function properly.
3.2.7 Brine Tank Maintenance and Salt
Refill the brine tank as necessary, making sure at least 1/3 of the brine tank is full at all times. Without proper salt levels,
the water softener may not operate properly.
The manufacturer recommends the use of solar salt for best results. The brine tank is manufactured for the use of solar,
pellets, or rock salt. If rock salt is used, a cleaning of the brine tank every six months is recommended.
3.3 Start-up Instructions
•
After installation is complete, rotate bypass handles to bypass mode, refer to
.
•
Turn on water and check for leaks.
•
Fully open a cold water faucet - preferably a laundry sink or bathtub with no aerator.
•
Allow water to run until clear to rid pipes of debris which may have occurred during installation.
3.3.1 Softeners
System regeneration sequence will flow in the following order.
Note:
If the following order changes then refer to the “Dealer Manual” or contact VIQUA).
1.
BACKWASH
2.
REGENERANT DRAW AND SLOW RINSE
3.
FAST RINSE
4.
BRINE TANK REFILL
5.
END (return to service – softening)
The system is now ready for filling with water and for testing.
1.
With the softener in the bypass mode (
) and the control valve in normal operation where the display shows
either the time of day or the gallons remaining, manually add 5" of water to the regenerant tank.
Note:
If too much water is put into the brine tank during softener start up, it could result in a “salty water” compliant
after the first regeneration.
During the first regeneration the unit will draw out the initial volume of brine/regenerant and refill it with the correct
preset amount.
2.
Press and hold the
REGEN
button until the motor starts. Release button. The display reads “
BACKWASH
” and the
remaining time in this step is counting down. Unplug the transformer so that the valve will not cycle to the next
position. Open the inlet handle of the bypass valve very slightly allowing water to fill the tank slowly in order to expel
air.
C A U T I O N
Damage or destruction to the media may occur if salts containing additives are used with the Sanitizer models. Most “solar” and/or “block” salts do not
contain additives detrimental to this unit. If unsure, please check with manufacturer. Many “pellet” or “cube” type salts are formulated with cleaning
agents or additives which can cause harm to the media. Salt manufacturers do not always list additives in their products. Please check with salt
manufacturers for any cleaning agents, binders or phosphate material added to salt.