Operation
7
Section 3
Operation
3.1 Programming Procedures
3.1.1 Set Time of Day
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends. If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset.
Procedure:
3.1.2 Programming
Note:
The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated after
the hardness is entered.
Procedure:
1
•
Press
SET
CLOCK
.
2
•
For Current Time (hour), set
the hour of the day using
+
or
–
buttons. “
AM
/
PM
” toggles
after 12.
•
Press
NEXT
.
3
•
For Current Time (minutes),
set the minutes using
+
or
–
buttons. If it is desired to back
up to the previous step press
REGEN
button once.
•
Press
NEXT
.
4
RETURN TO
GENERAL
DISPLAY
•
For Current Day, set the day
of the week using
+
or
–
buttons. If it is desired to back
up to the previous step press
REGEN
button once.
•
Pressing
NEXT
will exit
SET
CLOCK
and return to the
general operating display.
1
•
Press
NEXT
and
+
simultaneously for 3 seconds.
2
WATER HARDNESS
SET
20
GR
• Hardness
: Set the amount of
hardness in grains per gallon
(default 20) using the
+
or
–
buttons. The allowable range
is from 1 to 150 in 1 grain
increments.
3
Days Between Regeneration (Day Override):
•
Set Day Override using
+
or
–
buttons (6 is recommended):
•
Set number of days between regeneration (1 to 28) or
•
Set to “
OFF
”
•
Press
NEXT
or press
REGEN
to return to the previous step.
Note:
The manufacturer has factory set 6 days as the default. This is
the maximum number of days between regenerations. If this is set to
“OFF”, regeneration initiation is based solely on gallons used. If any
number is set (allowable range from 1 to 28), a regeneration initiation
will be called for on that day even if a sufficient number of gallons
were not used to call for a regeneration.