background image

4

46

6

© 2005 Directed Electronics, Inc. Vista, CA

"Type E - Mercedes-Benz and Audi -1985 and Newer" diagram.)

1

1--8

8  FFO

OR

RCCEED

D  P

PA

ASSSSIIV

VEE  A

AR

RM

MIIN

NG

G  O

ON

N//O

OFFFF:: To use this feature, passive arming must be selected in Feature 1-1. When

turned on, forced passive arming will ensure that the system will passively arm, even if a zone is left open or

invalid. Forced passive arming occurs one hour after the ignition is turned off.

1

1--9

9  A

AU

UTTO

OM

MA

ATTIICC  EEN

NG

GIIN

NEE  D

DIISSA

AB

BLLEE  ((A

AEED

D))  O

ON

N//O

OFFFF: AED is a full-time, passive starter disable that works independ-

ently of the security system. When turned on, the orange, ground-when-armed output (H1/1) will activate 30

seconds after the ignition is turned off. The LED will flash at half its normal rate when the ignition is turned off

to indicate that AED is active and will interrupt the starter in 30 seconds. AED does not occur in Valet® mode

and can be bypassed using the emergency override procedure. The transmitter can be used to disarm AED,

however, the system must be armed and then disarmed, using the transmitter, to disarm AED.

1

1--1

10

0  A

AR

RM

MEED

D  W

WH

HIILLEE  D

DR

RIIV

VIIN

NG

G  ((A

AW

WD

D))  O

ON

N//O

OFFFF:: In the default setting (Armed While Driving), the system can be

armed with the ignition on. When armed, the ground-when-armed is not active and the sensors are bypassed.

The door triggers will remain active.

1

1--1

11

1  CCO

OD

DEE  H

HO

OP

PP

PIIN

NG

G™

™  O

ON

N//O

OFFFF:: The system uses a mathematical formula to change its code each time the trans-

mitter and receiver communicate. This makes the group of bits or "word" from the transmitter very long. The

longer the word is, the easier it is to block its transmission to the unit. Disabling the Code Hopping™ feature

lets the receiver ignore the Code Hopping™ part of the transmitted word. As a result, the unit may have better

range with Code Hopping™ off.

2

2--1

1  SSIIR

REEN

N  O

OU

UTTP

PU

UTT  CCO

ON

NSSTTA

AN

NTT//P

PU

ULLSSEED

D:: The system can be programmed to output pulses instead of a continuous

output when the system is triggered. This is useful to honk the factory horn in applications where a siren is unde-

sirable. Remember that the unit is only capable of supplying 1 amp of current. A relay will be required to

interface with most factory horn systems.

2

2--2

2  SSIIR

REEN

N  D

DU

UR

RA

ATTIIO

ON

N  3

30

0//6

60

0  SSEECCO

ON

ND

DSS:: It is possible to program the unit to sound for 30 or 60 seconds

during the triggered sequence. Some states have laws regulating how long a security system can sound.

When using the TechSoft Programmer or Bitwriter®, the siren can be programmed to sound for any length of time

from 1 second to 180 seconds. Use the right and left arrows or the plus (+) and minus (-) keys on your keyboard

to change the siren duration in 1 second intervals. Holding down the key will rapidly increase or decrease the setting.

The desired siren duration can also be directly entered by using the number keys on your computer's keyboard.

2

2--3

3  N

NU

UIISSA

AN

NCCEE  P

PR

REEV

VEEN

NTTIIO

ON

N  CCIIR

RCCU

UIITTR

RY

Y  ((N

NP

PCC®

®))  O

ON

N//O

OFFFF:: NPC® stops repeated triggering of the same zone. If one

zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time of the third

trigger. During that hour, if the system sees a trigger on that zone again, the system resets the one hour timer.

If one hour passes and the zone has not triggered again, the zone is activated and can trigger the system again.

m

meennuu  ##22  --  aaddvvaanncceedd  ffeeaattuurreess

Содержание 791 XV

Страница 1: ...installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in severe damage to a vehicle s electrical system and compo...

Страница 2: ...Away are all Trademarks or Registered Trademarks of Directed Electronics Inc N Ne ew w S So of ft tw wa ar re e C Co om mp pa at ti ib bi il li it ty y f fo or r 1 10 03 3T T K Ke ey yp pa ad d This...

Страница 3: ...ti io on n g gu ui id de e 2 24 4 n ne eu ut tr ra al l s sa af fe et ty y s sw wi it tc ch h i in nt te er rf fa ac ce e 2 26 6 testing the neutral safety switch 26 b by yp pa as ss si in ng g G GM...

Страница 4: ...e control transmitters to assure that the system does not unintentionally remote start the vehicle 4 T TH HE E U US SE ER R M MU US ST T I IN NS ST TA AL LL L A A C CA AR RB BO ON N M MO ON NO OX XI I...

Страница 5: ...N C CO OS ST TS S iin ns st ta alllla at tiio on n p po oiin nt ts s t to o r re em me em mb be er r I IM MP PO OR RT TA AN NT T This product is designed for fuel injected automatic transmission vehic...

Страница 6: ...as the factory When possible place the siren on the same side of the vehicle as the control module where its wires will reach the control module s wires without extending them Always run the wires thr...

Страница 7: ...other heat sources and any obvious leaks H Ho ow w t th he e S St ti in ng ge er r i is s m mo ou un nt te ed d i is s t th he e m mo os st t i im mp po or rt ta an nt t f fa ac ct to or r i in n i it...

Страница 8: ...ess critical in day to day use As long as the Valet Program switch can be reached to disarm without a transmitter easy access is not important T Th hi in ng gs s t to o r re em me em mb be er r w wh h...

Страница 9: ...t will be located you re going to find the wires in the car that the security system will be connected to I IM MP PO OR RT TA AN NT T Do not use a 12V test light or logic probe computer safe test ligh...

Страница 10: ...ectly to the starter or to a relay controlling the starter In some vehicles it is necessary to power a cold start circuit A cold start circuit will test exactly like a starter circuit but it does not...

Страница 11: ...ttach the probe of the meter to chassis ground 3 Start and run the vehicle 4 Probe the wire you suspect of being the tachometer wire with the red probe of the meter 5 If this is the correct wire the m...

Страница 12: ...e Usually the area near the headlight parking light switch is an excellent area to start as is the kick panel 4 Turn on the parking lights If your meter shows 12V turn off the parking lights and make...

Страница 13: ...vides a door trigger m ma ak kiin ng g y yo ou ur r w wiir riin ng g c co on nn ne ec ct tiio on ns s Before making your connections plan how your wires will be routed through the vehicle For instance...

Страница 14: ...H2 2 5 5 H H2 2 6 6 R RE ED D W WH HI IT TE E 2 20 00 0 m mA A C CH HA AN NN NE EL L 2 2 V VA AL LI ID DI IT TY Y O OU UT TP PU UT T R RE ED D C CO ON NS ST TA AN NT T P PO OW WE ER R I IN NP PU UT T...

Страница 15: ...P PU UR RP PL LE E 2 20 00 0 m mA A S ST TA AR RT TE ER R R RE EL LA AY Y T TU UR RN N O ON N O OR RA AN NG GE E 2 20 00 0 m mA A A AC CC CE ES SS SO OR RY Y R RE EL LA AY Y T TU UR RN N O ON N P PI I...

Страница 16: ...E 2 20 00 0 m mA A 2 2N ND D S ST TA AT TU US S R RE EA AR R D DE EF FO OG GG GE ER R L LA AT TC CH HE ED D P PU UL LS SE ED D H H3 3 1 1 H H3 3 2 2 H H3 3 3 3 H H3 3 4 4 H H3 3 5 5 R RE ED D W WH HI...

Страница 17: ...wire supplies a 200 mA output This is suitable for driving light control wires in Toyota Lexus BMW some Mitsubishi some Mazda and other model cars P Po os si it ti iv ve e L Li ig gh ht t F Fl la as...

Страница 18: ...ay as shown below I IM MP PO OR RT TA AN NT T This output is only intended to drive a relay It cannot be connected directly to the domelight circuit as the output cannot support the current draw of on...

Страница 19: ...et wire to a wire that shows 12V when any door is opened and ground when the door is closed This wire will report Zone 3 Remove any paint and connect this wire to bare metal preferably with a factory...

Страница 20: ...system receives the code controlling Channel 2 for longer than 1 5 seconds the red white wire will supply an output as long as the transmission continues This is often used to operate a trunk hatch re...

Страница 21: ...actory anti theft device Use a relay to send a or pulse to the arm wire Connect this wire to the wire in the vehicle that sends the signal to turn on the WAIT TO START bulb in the dash board In most d...

Страница 22: ...d to pulse the disarm wire of the vehicle s factory anti theft device Use a relay to send a or pulse to the disarm wire as shown in the following diagrams R Re el la ay y f fo or r N Ne eg ga at ti iv...

Страница 23: ...em until the satellite has been plugged into the control module These wires are the source of current for all the circuits the relay satel lite will energize They must be connected to a high current s...

Страница 24: ...also be used to rearm a factory anti theft system when the remote start shuts down See the Feature Descriptions section of this guide To bypass an optional sensor This wire MUST be connected to hood...

Страница 25: ...h in the vehicle This wire will test with ground with the gear selector either in PARK or NEUTRAL This will prevent the vehicle from accidentally being started while in a drive gear This input MUST re...

Страница 26: ...uilt into the column shifter can usually be identified by a purple starter wire Typically vehicles that use an outboard mechanical switch use a yellow wire from the ignition switch to the mechanical s...

Страница 27: ...ion with the driver s door open the remote start system will shut down If this interface is used it is important to inform the cus tomer to close the driver s door before inserting the key into the ig...

Страница 28: ...s sp po or rt t u ut ti il li it ty y v ve eh hi ic cl le es s a an nd d c co ol lu um mn n s sh hi if ft ti in ng g p pa as ss se en ng ge er r v ve eh hi ic cl le es s P Pr re e 1 19 99 96 6 D Do od...

Страница 29: ...two very light gauge wires coming out of the steering column The colors of the wires vary but they are often contained in orange tubing either both will be white wires or one wire will be purple white...

Страница 30: ...ock systems require seeing the correct R code at the correct time To bypass Passlock I and II p p n n 5 55 55 5L L or p p n n 5 55 55 5T T is required The Passkey III system can be found in the follow...

Страница 31: ...rogram Switch should be plugged into the larger blue two pin connector The Status LED fits into a 9 32 inch hole S St ta at tu us s L LE ED D V Va al le et t P Pr ro og gr ra am m S Sw wi it tc ch h p...

Страница 32: ...ad dd di in ng g o op pt ti io on na al l D Di ir re ec ct te ed d E El le ec ct tr ro on ni ic cs s d du ua al l s st ta ag ge e s se en ns so or r t to o g gr re ee en n w wi ir re e Z Zo on ne e 2...

Страница 33: ...n t th he e t ta ac ch h s si ig gn na al l 1 Start the vehicle with the key 2 Within 5 seconds press and H HO OL LD D the Valet Program switch 3 The LED will light constant when the tach signal is l...

Страница 34: ...H1 2 light flash output harness wire t tr ra an ns sm miit tt te er r r re ec ce eiiv ve er r lle ea ar rn n r ro ou ut tiin ne e The system comes with one transmitter that has been taught to the rec...

Страница 35: ...the button that was entered into Channel Two C Ch ha an nn ne el l T Tw we el lv ve e If any transmitter button from a known transmitter is programmed to Channel Twelve all trans mitters will be erase...

Страница 36: ...you want to program Channel Three after programming Channel One release the Valet Program switch Press it twice and release it to advance to Channel Three Then press it once more and H HO OL LD D it...

Страница 37: ...ming and Panic Mode activation with separate buttons When programmed for standard configuration the transmitter buttons are assigned to the following functions operates Arm Lock Panic ON Panic OFF ope...

Страница 38: ...3 38 8 2005 Directed Electronics Inc Vista CA r re em mo ot te e c co on nt tr ro oll d diia ag gr ra am m...

Страница 39: ...dicator 9 Door Switch Input Indicator 10 Warn Away Response Indicator 11 Siren Status Indicator 12 Battery Level Indicator 13 Trigger Response Indicator 14 Hood Switch Input Indicator 15 Ignition Swit...

Страница 40: ...te the Multi Level Security feature Each time the arm button is pressed again a different security level is selected The different levels of security are selected as follows Pressing one time The sire...

Страница 41: ...annot be done manually with the Valet switch If the learn routine is locked features cannot be changed T To o e en nt te er r t th he e S Sy ys st te em m F Fe ea at tu ur re es s L Le ea ar rn n R Ro...

Страница 42: ...the Valet Program switch the number of times necessary to advance from the feature you just programmed to the next one you want to program 2 Then press the Valet Program switch once more and H HO OL...

Страница 43: ...m d di is sa ar rm m c ch hi ir rp ps s o on n Arm disarm chirps off 1 3 I Ig gn ni it ti io on n c co on nt tr ro ol ll le ed d d do oo or r l lo oc ck ks s Standard door locks 1 4 I Ig gn ni it ti...

Страница 44: ...op pt ti io on ns s F FE EA AT TU UR RE E N NU UM MB BE ER R O ON NE E C CH HI IR RP P S SE ET TT TI IN NG G D DE EF FA AU UL LT T T TW WO O C CH HI IR RP P S SE ET TT TI IN NG G 2 1 S Si ir re en n...

Страница 45: ...UN NL LO OC CK K When turned ON the doors will unlock when the ignition is turned OFF 1 1 5 5 A AC CT TI IV VE E P PA AS SS SI IV VE E L LO OC CK KI IN NG G If passive arming is selected in Feature 1...

Страница 46: ...it is to block its transmission to the unit Disabling the Code Hopping feature lets the receiver ignore the Code Hopping part of the transmitted word As a result the unit may have better range with C...

Страница 47: ...the door has been closed If the system is armed before the dome light has turned off the security system will generate the door trigger error chirp If this error chirp is not desired use this feature...

Страница 48: ...gine until the system times out This is the maximum operation period and the system may be shut down using a shutdown at any time Using the Bitwriter the run time can be programmed for any duration fr...

Страница 49: ...e active during remote start operation If accessories such as a voice module or window module are added to the unit it may be necessary to program this feature off n nu uiis sa an nc ce e p pr re ev v...

Страница 50: ...start and run the engine every three hours for a maximum of six cycles The engine will run for the programmed run time and then shut down After three hours the system will restart the engine I IM MP P...

Страница 51: ...w wn n d diia ag gn no os st tiic cs s 1 With the ignition OFF press and H HO OL LD D the Valet Program switch 2 Turn the ignition ON and then back OFF while H HO OL LD DI IN NG G the Valet Program sw...

Страница 52: ...nition 3 Release the Valet Program switch 4 Press and release the Valet Program switch within 5 seconds The LED will flash in groups indicating the last two zones that triggered the unit for one minut...

Страница 53: ...should not engage with the hood open 3 Test the NEUTRAL SAFETY shutdown circuit I IM MP PO OR RT TA AN NT T Make sure there is adequate clearance to the front and rear of the vehicle before attempting...

Страница 54: ...oor inputs connected Is the H1 6 blue wire connected to the door trigger wire in the vehicle Either the H1 5 green or the H1 7 violet should be used instead See wiring diagrams D Do oo or r i in np pu...

Страница 55: ...the fuel and or spark during unau thorized starting attempts 2 Is the remote start programmed for voltage sense If so the start time may not be set high enough or you may have to adjust the voltage th...

Страница 56: ...5 56 6 2005 Directed Electronics Inc Vista CA w wiir riin ng g q qu uiic ck k r re ef fe er re en nc ce e g gu uiid de e...

Страница 57: ...2005 Directed Electronics Inc Vista CA 5 57 7 r re ella ay y s sa at te elllliit te e w wiir riin ng g q qu uiic ck k r re ef fe er re en nc ce e g gu uiid de e...

Страница 58: ...5 58 8 2005 Directed Electronics Inc Vista CA...

Отзывы: