4
46
6
© 2005 Directed Electronics, Inc. Vista, CA
"Type E - Mercedes-Benz and Audi -1985 and Newer" diagram.)
1
1--8
8 FFO
OR
RCCEED
D P
PA
ASSSSIIV
VEE A
AR
RM
MIIN
NG
G O
ON
N//O
OFFFF:: To use this feature, passive arming must be selected in Feature 1-1. When
turned on, forced passive arming will ensure that the system will passively arm, even if a zone is left open or
invalid. Forced passive arming occurs one hour after the ignition is turned off.
1
1--9
9 A
AU
UTTO
OM
MA
ATTIICC EEN
NG
GIIN
NEE D
DIISSA
AB
BLLEE ((A
AEED
D)) O
ON
N//O
OFFFF: AED is a full-time, passive starter disable that works independ-
ently of the security system. When turned on, the orange, ground-when-armed output (H1/1) will activate 30
seconds after the ignition is turned off. The LED will flash at half its normal rate when the ignition is turned off
to indicate that AED is active and will interrupt the starter in 30 seconds. AED does not occur in Valet® mode
and can be bypassed using the emergency override procedure. The transmitter can be used to disarm AED,
however, the system must be armed and then disarmed, using the transmitter, to disarm AED.
1
1--1
10
0 A
AR
RM
MEED
D W
WH
HIILLEE D
DR
RIIV
VIIN
NG
G ((A
AW
WD
D)) O
ON
N//O
OFFFF:: In the default setting (Armed While Driving), the system can be
armed with the ignition on. When armed, the ground-when-armed is not active and the sensors are bypassed.
The door triggers will remain active.
1
1--1
11
1 CCO
OD
DEE H
HO
OP
PP
PIIN
NG
G™
™ O
ON
N//O
OFFFF:: The system uses a mathematical formula to change its code each time the trans-
mitter and receiver communicate. This makes the group of bits or "word" from the transmitter very long. The
longer the word is, the easier it is to block its transmission to the unit. Disabling the Code Hopping™ feature
lets the receiver ignore the Code Hopping™ part of the transmitted word. As a result, the unit may have better
range with Code Hopping™ off.
2
2--1
1 SSIIR
REEN
N O
OU
UTTP
PU
UTT CCO
ON
NSSTTA
AN
NTT//P
PU
ULLSSEED
D:: The system can be programmed to output pulses instead of a continuous
output when the system is triggered. This is useful to honk the factory horn in applications where a siren is unde-
sirable. Remember that the unit is only capable of supplying 1 amp of current. A relay will be required to
interface with most factory horn systems.
2
2--2
2 SSIIR
REEN
N D
DU
UR
RA
ATTIIO
ON
N 3
30
0//6
60
0 SSEECCO
ON
ND
DSS:: It is possible to program the unit to sound for 30 or 60 seconds
during the triggered sequence. Some states have laws regulating how long a security system can sound.
When using the TechSoft Programmer or Bitwriter®, the siren can be programmed to sound for any length of time
from 1 second to 180 seconds. Use the right and left arrows or the plus (+) and minus (-) keys on your keyboard
to change the siren duration in 1 second intervals. Holding down the key will rapidly increase or decrease the setting.
The desired siren duration can also be directly entered by using the number keys on your computer's keyboard.
2
2--3
3 N
NU
UIISSA
AN
NCCEE P
PR
REEV
VEEN
NTTIIO
ON
N CCIIR
RCCU
UIITTR
RY
Y ((N
NP
PCC®
®)) O
ON
N//O
OFFFF:: NPC® stops repeated triggering of the same zone. If one
zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time of the third
trigger. During that hour, if the system sees a trigger on that zone again, the system resets the one hour timer.
If one hour passes and the zone has not triggered again, the zone is activated and can trigger the system again.
m
meennuu ##22 -- aaddvvaanncceedd ffeeaattuurreess