background image

18

©

2002 

Directed Electronics, Inc.

Feature Descriptions

The features of the system are described below. Features that have additional settings that can be
selected only when programming with the 998T Bitwriter are indicated by the following
icon:

Menu #1 - Basic Features

1-1 ACTIVE/PASSIVE ARMING:

When active arming is selected, the system will only arm when

the transmitter is used. When set to passive, the system will arm automatically 30 seconds after the
last door is closed. To alert the consumer of passive arming, the siren will chirp 20 seconds after the
door is closed. This provides the consumer with an audible indication prior to the system actually
arming. At the 30 second mark, the system will arm but the siren will not chirp.

1-2 CHIRPS ON/OFF:

This feature controls the chirps that confirm the arming and disarming of

the system.

1-3 IGNITION CONTROLLED DOOR LOCKS ON/OFF: 

When turned on, the doors will

lock three seconds after the ignition is turned on and unlock when the ignition is turned off.

The 998T Bitwriter will display separate steps for ignition lock and ignition unlock. They can be
programmed on or off independently.

1-4 ACTIVE/PASSIVE LOCKING: 

If passive arming is selected in step 1-1, then the system can be

programmed to either lock the doors when passive arming occurs, or only lock the doors when the
system is armed via the transmitter. Active locking means the system will not lock the doors when
it passively arms. Passive locking means that the system will lock the doors when it passively arms.

NOTE: Remember, when passive arming is selected, the unit will chirp 20 seconds after the last
door is closed. The system does not actually arm or lock the doors until 30 seconds after the door
has been closed.

1-5 PANIC WITH IGNITION ON: 

This step controls whether or not the Panic Mode is available

with the ignition on. In some states, there are laws prohibiting a siren from sounding in a moving
vehicle. This feature makes the system compliant with these regulations.

1-6 DOOR LOCK PULSE DURATION: 

Some European vehicles, such as Mercedes-Benz and

Audi, require longer lock and unlock pulses to operate the vacuum pump. Programming the system
to provide 3.5 second pulses, will accommodate the door lock interface in these vehicles. The default
setting is 0.8 second door lock pulses. 

Содержание 650XV

Страница 1: ...ta CA N436V 10 02 NOTE This product is intended for installation by a professional installer only Any attempt to install this product by any person other than a trained professional may result in seve...

Страница 2: ...ay are all Trademarks or Registered Trademarks of Directed Electronics Inc The Bitwriter p n 998T requires chip version 1 4 or newer to program this unit w ww ww w d di ir re ec ct te ec ch hs s c co...

Страница 3: ...Me en nu us s 1 17 7 Menu 1 Basic Features 17 Menu 2 Advanced Features 17 F Fe ea at tu ur re e D De es sc cr ri ip pt ti io on ns s 1 18 8 Menu 1 Basic Features 18 Menu 2 Advanced Features 19 T Tr r...

Страница 4: ...oon as the system is disarmed The ORANGE wire is pre wired to control the 8618 starter kill relay It can supply up to 500 mA of current NOTE If using the H1 1 ORANGE wire to activate an add on accesso...

Страница 5: ...us BMW some Mitsubishi some Mazda and other models NOTE For parking light systems that draw 10 amps or more the jumper must be switched to a light flash output see the Programming Jumpers section of t...

Страница 6: ...ti im me ed d output will send a signal for 30 seconds when channel three is pressed This output can be shut off during the 30 second period by pressing Channel 3 again This output can also be progra...

Страница 7: ...E instant trigger input This input will respond to a negative input with an instant trigger It is ideal for hood and trunk pins and will report on Zone 1 It can also be used with Directed single stage...

Страница 8: ...und points It is recommended that all security components be grounded at the same location H1 9 YELLOW ignition input Connect this wire to the 12 volts ignition wire This wire is pre wired to the star...

Страница 9: ...e protects the module itself H1 12 RED WHITE 200 mA channel 2 output When the system receives the code controlling channel 2 for longer than 1 5 seconds the RED WHITE will supply an output as long as...

Страница 10: ...rates at 2 volt DC and plugs into the two pin WHITE port Make sure the LED wires are not shorted to ground as the LED will be damaged Multiple LED s can be used but they must be wired in series The LE...

Страница 11: ...or more infor mation please refer to the guide packaged with the programmer This port can also be used to interface with Directed Video components for on screen security system programming and trigger...

Страница 12: ...an 0 8 seconds will trigger full alarm sequence and report Zone 4 NOTE If installing an optional Directed dual stage sensor connect to the GREEN wire The following diagram eliminates the need for diod...

Страница 13: ...elay is enabled and the unit will output 12V on the WHITE wire H1 2 In the position the on board relay is disabled The WHITE wire H1 2 will supply a 200 mA output suitable for driving factory parking...

Страница 14: ...tem Features Learn Routine dictates how the unit operates Due to the number of steps they have been broken up into two menus It is possible to access and change any of the feature settings using the V...

Страница 15: ...onding to the feature you wish to change For example to access the third feature press and release the switch three times Then press the switch once more and HOLD it The siren will chirp the number of...

Страница 16: ...it once more and HOLD it The siren would chirp seven times to confirm access to the seventh feature To select another menu 1 Press and HOLD the Valet Program switch 2 After three seconds the unit will...

Страница 17: ...olled domelight OFF 2 8 Single unlock pulse Double unlock pulse 2 9 Channel 3 Validity Channel 3 latched latched reset with ignition 30 second timed second unlock output Second unlock is only availabl...

Страница 18: ...s for ignition lock and ignition unlock They can be programmed on or off independently 1 4 ACTIVE PASSIVE LOCKING If passive arming is selected in step 1 1 then the system can be programmed to either...

Страница 19: ...rammed to the Vehicle Recovery System VRS setting VRS will be activated 1 10 CODE HOPPING ON OFF The system uses a mathematical formula to change its code each time the transmitter and receiver commun...

Страница 20: ...s programmed off the full siren output will occur the moment the door is opened 2 5 VALET PULSE COUNT ONE TO FIVE PULSES The system can be programmed to count the number presses of the valet button be...

Страница 21: ...Bitwriter the learn routine may be locked If the siren generates one long chirp when attempting to program the unit the learn routine is locked and must be unlocked using the 998T Bitwriter before pr...

Страница 22: ...on from a known transmitter is programmed to Channel 9 all transmitters will be erased from memory and the system features will revert to the default settings This is useful in cases where the one of...

Страница 23: ...rate buttons When programmed for standard configuration the transmitter buttons are assigned to the following functions operates Arm only operates Disarm only operates Channel 2 and Silent Mode operat...

Страница 24: ...optional hood trunk pins 2 Multiplexed BLUE wire of plug in shock sensor Inputs shorter than 0 8 seconds will trigger a Warning Zone response while inputs longer than 0 8 seconds will instantly trigge...

Страница 25: ...Valet Program switch 4 Press and release the Valet Program switch within five seconds The LED will flash in groups indicating the last two zones that triggered the unit The LED will flash for one minu...

Страница 26: ...on Circuitry Nuisance Prevention Circuitry bypasses any zone that triggers the system more than three times within a one hour period For a full description of NPC operations refer to the Owner s Guide...

Страница 27: ...ggers the system but opening the door does not Have you correctly identified the type of door switch system This happens often when the wrong door input has been used System will not passively arm unt...

Страница 28: ...28 2002 Directed Electronics Inc Wiring Quick Reference Guide...

Отзывы: