10

feature descriptions

The features of the system are described below. Features that have additional settings that can be selected only

when programming with the PC interface or Bitwriter are indicated by the following icon: 

1-1 ACTIVE/PASSIVE ARMING:

When active arming is selected, the system will only arm when the transmitter is

used. When set to passive, the system will arm automatically 30 seconds after the last door is closed. To alert

the consumer of passive arming, the siren will chirp 20 seconds after the door is closed. This provides the con-

sumer with an audible warning prior to the system actually arming. At the 30 second mark, the system will arm

but the siren will not chirp.

1-2 Chirps ON/OFF: This feature controls the chirps or voice messages (if using the 516M voice module) that

confirm the arming and disarming of the system.

1-3 IGNITION CONTROLLED DOOR LOCKS ON/OFF: 

When turned on, the doors will lock three seconds after

the ignition is turned on and unlock when the ignition is turned off. The 

TechSoft Programmer or the 

998T

Bitwriter

will display separate steps for ignition lock and ignition unlock. They can be programmed on or off inde-

pendently.

1-4 ACTIVE/PASSIVE LOCKING:

If passive arming is selected in step 1-1, then the system can be programmed

to either lock the doors when passive arming occurs, or only lock the doors when the system is armed via the

transmitter. Active locking means the system will not lock the doors when it passively arms. Passive locking means

that the system will lock the doors when it passively arms.

NOTE: 

Remember, when passive arming is selected, the unit will chirp 20 seconds after the last door is

closed. The system does not actually arm or lock the doors until 30 seconds after the door has been closed.

1-5 PANIC WITH IGNITION ON: 

This step controls whether or not the Panic Mode is available with the ignition

on. In some states, there are laws prohibiting a siren from sounding in a moving vehicle. This feature makes the 

system compliant with these regulations.

1-6 DOOR LOCK PULSE DURATION:

Some European vehicles, such as Mercedes-Benz and Audi, require longer lock

and unlock pulses to operate the vacuum pump. Programming the system to provide 3.5 second pulses, will

accommodate the door lock interface in these vehicles. The default setting is 0.8 second door lock pulses. 

1-7 FORCED PASSIVE ARMING ON/OFF:

To use this feature, passive arming must be selected in step 1-1. When

turned on, forced passive arming will ensure that the system will passively arm, even if a zone is left open or

invalid. Forced passive arming occurs one hour after the ignition is turned off.

menu #1 - basic features

Содержание 420ESP

Страница 1: ...opping DEI Doubleguard ESP FailSafe Ghost Switch Learn Routine Nite Lite Nuisance Prevention Circuitry NPC Revenger Silent Mode Soft Chirp Stinger Valet Vehicle Recovery System VRS and Warn Away are a...

Страница 2: ...IREN OUTPUT YELLOW SWITCHED IGNITION INPUT ZONE 5 BLACK CHASSIS GROUND INPUT VIOLET DOOR TRIGGER INPUT ZONE 3 BLUE INSTANT TRIGGER INPUT ZONE 1 GREEN DOOR TRIGGER INPUT ZONE 3 BLACK WHITE 200 mA DOMEL...

Страница 3: ...ut any additional parts With certain vehicles or if an actuator is to be installed either a p n 451M Door Lock Relay Satellite or two relays will be required IMPORTANT If you mistake a Type C direct w...

Страница 4: ...arance before drilling a 9 32 inch hole and mounting the switch The GRAY wire in the two pin plug may also be used as a ghost switch input and can be connected to any switch in the vehicle See Feature...

Страница 5: ...TE When adjusting the sensor it must be in the same mounting location that it will be after the installation is completed Adjusting the sensor and then relocating the module requires read justment opt...

Страница 6: ...hen you need to temporarily bypass all sensor inputs to the unit such as when remote start ing the vehicle Anytime an auxiliary channel output is used all inputs are bypassed for 5 seconds During the...

Страница 7: ...n Turn the ignition on then back off The H1 9 YELLOW wire must be connected 3 Select a Menu Press and HOLD the Valet Program button The Valet Program button must be plugged into the blue port After th...

Страница 8: ...es and then press it once more and HOLD it The siren would chirp seven times to confirm access to the seventh feature 1 Press and HOLD the Valet Program switch 2 After three seconds the unit will adva...

Страница 9: ...rolled domelight OFF 2 8 Single unlock pulse Double unlock pulse 2 9 Channel 3 Validity Channel 3 latched latched reset with ignition 30 second timed second unlock output menu 2 advanced features FEAT...

Страница 10: ...ssive arming is selected in step 1 1 then the system can be programmed to either lock the doors when passive arming occurs or only lock the doors when the system is armed via the transmitter Active lo...

Страница 11: ...riggered This is useful to honk the factory horn in applications where a siren is undesirable Remember that the unit is only capable of supplying 1 amp of current A relay will be required to interface...

Страница 12: ...ON OFF With the door trigger error chirp programmed off the system will not report an invalid zone on arming when the door trigger wire is active This eliminates the extra chirps that occur when inte...

Страница 13: ...ire must be connected 2 Key Turn the ignition on The YELLOW wire H1 9 must be connected 3 Select the receiver channel Press and release the Valet Program button the number of times necessary to access...

Страница 14: ...red into channel one the remote will be erased from memory and the system will only recognize the button that was entered into channel one Channel 9 If any transmitter button from a known transmitter...

Страница 15: ...systems that use sepa rate remote transmitter buttons for the arm disarm panic and auxiliary output functions operates Arm only operates Disarm only operates Channel 2 operates Panic and operate Chan...

Страница 16: ...16 2000 Directed Electronics Inc Vista CA wiring quick reference guide...

Отзывы: