Chapter 3 Deployment
Manual VIPA System SLIO
3-6
HB300E - FM - RE_050-1BA10 - Rev. 10/30
Addr.
Name
Bytes Function
IX
SX
+0 CC_I 4
Comparison
value
5600h
01h
+4 CS_I 4
Set
value
5601h
02h
+8 CCTRL_I 2
Control
word
5602h
03h
With
comparison value
a value may be preset that may influence the
comparison bit
res. throw a process interrupt when compared with the
recent
counter value
. The behavior of the
comparison bit
respectively the
process interrupt may be set via the parameter MODE2_I respectively
INIT_I.
By means of the
set value
there is the possibility to preset the counter with
the
set value
. The value is kept by the counter by an changing edge 0-1 of
the bit COUNTERVAL_SET in the
control word
.
Bit
Name
Function
0
CTRL_SYNC_SET
activates the reset mode
1 CTRL_COMP_SET
enables
the
comparison bit
2
SW_GATE_SET
sets the software gate
3 ... 4
- reserved
5
COUNTERVAL_SET sets counter temporarily to the value of
set
value
6
RES_SET
resets the bits STS_CMP, STS_END,
STS_OFLW, STS_UFLW and STS_ZP
with rising edge
7 -
reserved
8
CTRL_SYNC_RESET deactivates the reset mode
9 CTRL_COMP_RESET disables
the
comparison bit
10
SW_GATE_RESET
resets the software gate
11 ... 15
-
reserved
Output area
10byte
CC_I
Comparison value
CS_I
Set value
CCTRL_I
Control word
Содержание SLIO System FM 050-1BA10
Страница 1: ...VIPA System SLIO FM 050 1BA10 Manual HB300E_FM RE_050 1BA10 Rev 10 30 July 2010...
Страница 4: ...Contents Manual VIPA System SLIO ii HB300E FM RE_050 1BA10 Rev 10 30...
Страница 8: ...Safety information Manual VIPA System SLIO 4 HB300E FM RE_050 1BA10 Rev 10 30...
Страница 56: ...Chapter 3 Deployment Manual VIPA System SLIO 3 24 HB300E FM RE_050 1BA10 Rev 10 30...