3.4 

How to keep this I.M. 

The operating instruction manual has to be kept in perfect state and has to be always 
available for consultation. It has to follow the machine in case of transfer of property. It has to 
be kept until the demolition of the machine itself, 
To order the up-to-date versions of I.M. and for any further information, please contact 
Vinteck sas or the nearest Vinteck sas dealer. We will be pleased to receive your 
suggestions to improve our quality.  
Note for the use of this machine in a foreign country: contingent laws and restrictions in place 
for this kind of machine in the Country where it is used have to be respected also in the case 
are not mentioned in this manual. 
New updated release of the manual will be available on 

www.vinteck.com 

 

4-  V-8  : technical description 

True bypass system, working with silver golden relays. 
8 programmable loops, plus 2 extra loops for amps send return connections or non 
automated effects. 
It’s possible to connect 5 pedals in front of amps an 3 in effects loops, or 6 and 2. 
4 programmable switch completely independent from loops, for amps channel control. 
Any combination between loops,  switch and MIDI program change is possible.  
 
Buffered input, with on/off switch. Max input level +4dB 
Out tuner 
10 banks of 8 programs, total of 80 programs. 
Each bank may be deactivated (from 0 to 9) 
Direct activation of loops may be done with button program/loop 
MIDI manager with possibility of program change assign from 0 to 100 on all programs, 
independent from program number (MIDI MAPPING) 
MIDI TAP TEMPO with external pedals, Control Change is assignable from 1 to 128. 
MIDI channel manager input, output  e 0/1 assignament. 
MIDI IN and MIDI OUT with eco THRU (all incoming command comes send out as they are) 
All programming operations may be done standing up.  
2 digit Display   
12 VDC not stabilized power supply,  500mA 
Dimensions 33 x 12 cm. High 5,5 front, 6 cm back, staggered surface ad buttons positions, 
for easy access. 

 

 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

    

 

Содержание V-8

Страница 1: ... Vittorio Emanuele II 123 Tel 39 339 7626891 fax 39 011 547712 Laboratorio Via Limone 22 10141 Torino Nr Iscrizione RAEE IT08020000002500 web http www vinteck com e mail info vinteck com V 8 True bypass MIDI switching Pedalboard User manual Ed 01 rev 0 ...

Страница 2: ..._______________________________________________ 1 instrument marking V 8 got in back side a little non removable area with serial and years of building It is very important to report this information in case of need of technical supply Thank you very much for purchase of V 8 pedalboard We really hope that it will be good friend for several ours of music We ask you to write us by email at support v...

Страница 3: ... remaining risk A danger not completely reducible from the designing and the safety devices i e potential and not evident danger Since the productive aiming the mechanical qualities and the presupposed proper usage we didn t find any remaining risks both during the design and the tests Anyway we recommend to let only trained staff using the machine to check that the machine is supplied by an groun...

Страница 4: ...relays 8 programmable loops plus 2 extra loops for amps send return connections or non automated effects It s possible to connect 5 pedals in front of amps an 3 in effects loops or 6 and 2 4 programmable switch completely independent from loops for amps channel control Any combination between loops switch and MIDI program change is possible Buffered input with on off switch Max input level 4dB Out...

Страница 5: ...ny signal may be inserted LOOP1 5 loops managed from buttons 1 to 5 SND Signal for pedal input RTN Signal back from pedal EXT LOOP Fixed loop Usable for always ON pedals ex volume or for amp effect loop connection see Example LOOP6 loops managed from buttons 6 EXT LOOP Fixed loop Usable for always ON pedals ex volume or for amp effect loop connection see Example LOOP7 8 loops managed from buttons ...

Страница 6: ...MS plus several MIDI functions Button UP allows ratation of banks and selection of number od actve banks plus MIDI functions WIRING AND CONNECTIONS EXAMPLES V 8 must be powered with original power supply only Insert the power supply cord in his plug When powered the V UNO is active WORNING never cut the wire of 230 12VAC power supply Never open the V 8 power supply 230VAC inside when connected to ...

Страница 7: ... bypass MIDI switching pedalboard pag 7 Edition 01eng rev 0 Example 2 V 8 with 6 pedals in front and 3 in send return Example 3 V 8 with 6 pedals in front 2 pedals in send return and volume in send return before delays ...

Страница 8: ...nds Programming is active when white led start to blink Press buttons of loops desired Blue led show active loops Keep pressed buttons 1 4 for about 2 5 secs to activate switches Yellow led indicate switches ON Confirm and memorize programs pressing L P button BANKS ACTIVATION Factory preset comes with bans 1 9 not active Only bank 0 is active To activate banks 1 9 With blue led L press and keep f...

Страница 9: ...etween CC and a number from 0 to 99 then 0 0 to 2 8 for values from 100 to 128 Choose value with buttons UP and L P as down Preset values is CC 80 On some devices this the preset as well Check on users manual the right CC values Confirm and exit with button 8 PROGRAM CHANGE MIDI MAPPING V 8 allows to assign a PROGRAM CHANGE number difference from program number Factory preset got same number To ch...

Страница 10: ...omers All operation and any spare parts are covered by warranty Warranty do not cover the following cases Uncured utilization Damage from transportations Repairing and changes made without authorization Athmosferic Events Incorrect use of instruments Power supply not correct Use of not original spare parts Partial or total non observance of the instructions Use of the machine against national spec...

Страница 11: ...clared EN 55103 1 EN 55103 2 and 60062 1998 Manufacturer Vinteck SAS di Guido Michetti C Corso Vittorio Emanuele II 123 10128 Torino ITALY The equipment identified here conforms to the Directive s and Standards specified above Type of equipment Effects switching system Model TB10MKII TB5 V UNO V 8 Data september 2007 Vinteck sas di Guido Michetti C corso Vittorio Emanulele II 123 10128 Torino Ital...

Отзывы: