background image

Page 

12

Leak Testing 

GENERAL INFORMATION 

BEFORE TESTING 

TESTING 

Although all gas connections on 
your VINTAGE Grill are leaked 
tested at the factory  prior  to 
shipment, a complete gas tightness 
check must be performed  at  the 
installation site due to possible 
mishandling in  shipment,  or 
excessive  pressure  unknowingly 
being applied to  the  unit. 
Periodically check the whole 
system for leaks,  or  immediately 
check if the smell of gas is 
detected. 

Make sure that all packing material is 
removed from the grill including the 
burner tie-down straps. 

Check  all  gas  supply  fittings  before
each use.

Do not smoke while leak testing.

You will need a spray bottle or brush
to apply the solution to all connection
points to test for gas leaks. Make a
soap solution of one part liquid
detergent and one part water.

L.P. units, check with full cylinder.

Grills must be leak tested outdoors in
a well-ventilated area, away from any
ignition sources such as gas fired or
electrical appliances.  During leak
test, keep grill away from open flames
or sparks.

**Never leak test with an open flame** 

1) Always confirm that all burner control
knobs are in the OFF position.
2) Always connect the gas supply hose first
and then open the gas shutoff valve.
Turn on fuel supply. For natural gas, turn
valve handle ¼ turn to align with gas flow.
For LP turn cylinder valve knob  counter
clockwise one full rotation.
3) Use a spray bottle or brush to apply 50/50
solutions of liquid soap and water to all
connection points.
4) It is key to look for bubbles to appear, as
the appearance of bubbles will indicate a gas
leak. If a leak is present,  immediately
turn off gas supply valve and tighten  any
leaking fittings, or by replacing the faulty
part with a replacement part recommended
by  the manufacturer. DO NOT attempt to
repair  the LP cylinder valve if it  should
become damaged; the cylinder MUST be
replaced. Then turn gas on, and recheck.
5) Always repeat the following procedure
until no further gas leaks are detected before
lighting the Grill. NEVER attempt to light
this grill if a leak cannot be stopped.
6) If a leak cannot be stopped, turn off the
gas supply and call your dealer where you
purchased your Grill.
7) Only those parts recommended  by  the
manufacturer should be used on the grill.
Substitution can void the warranty. Do not
use the Grill until all connections have been
checked and do not leak.

IMPORTANT SAFETY CONSIDERATIONS 

IT IS IMPORTANT THAT LEAK TESTS MUST BE REPEATED EACH TIME LP CYLINDER IS 

EXCHANGED OR REFILLED.

 

If a leak is present, or if the connection hose shows signs of wear, these conditions must be corrected prior to using 

your grill.

 

Disconnected L.P. cylinders must have threaded valve plugs tightly installed, and must NOT be stored in a building, 

garage or any other enclosed area.

 

The gas must be turned off at the supply cylinder when the unit is not in use.

 

If the appliance is stored indoors, the cylinder must be disconnected and removed from the appliance. Cylinders 

must be stored outdoors in a well-ventilated area out of reach of children.

 

Areas to test for leaks 

Содержание VBQ-30G

Страница 1: ...Installation Operation Maintenance Instructions Parts List Owner s Manual For Outdoor Use Only MODELS VBQ 30GB VBQ 30G VBQ 36G VBQ 36SZG VBQ 42G VBQ 42SZG VBQ 56G VBQ 56SZG...

Страница 2: ......

Страница 3: ...lare Ups Cleaning Information Grill Rack Drip Tray Grill Burners IR Burners Orifice Cleaning Briquette Holder Stainless Steel 18 Troubleshooting Guide 18 Warranty Information 19 Table of Contents Cong...

Страница 4: ...Electrical Code ANSI NFPA 70 990 or Canadian Electrical code CSA C22 1 US 4006027 IMPORTANT The installer should leave these instructions with the consumer who local inspector s use reference The con...

Страница 5: ...ns Only certain types of glass heatproof glass ceramic earthenware or other glazed utensils are suitable for grill use Use of these types of materials may break with sudden temperature changes Use onl...

Страница 6: ...se this outdoor Grill inside any building garage shed or breezeway or inside any boat trailer or recreational vehicle to prevent a possible fire and to prevent the possibility of carbon monoxide poiso...

Страница 7: ...nto your Non s itioned correct o their locating fitted and the i regulator acco vice requiremen INSTRUCTI WIDTH 28 1 2 34 40 1 2 54 1 2 IMP Combustible e ly on their orif g pins and plac igniter cap i...

Страница 8: ...he rear casters to prevent unwanted grill movement IGNITER BATTERY INSTALLATION Install 9V igniter batteries 1 Locate the igniter modules at the bottom of the control panel by removing the drip tray 2...

Страница 9: ...must be attached to the three prong male plug on the back of the grill It is located on the lower right corner on the back of the grill This extension cord should be plugged into a nearby outlet Pleas...

Страница 10: ...g 10 W C non operating 11 2 W C L P TANK REQUIREMENTS Use only a standard 20 lb 5 gal Propane gas cylinder 18 1 4 H x 12 1 4 dia The tank must be installed in the upright position Do not use a dented...

Страница 11: ...C non operating 4 5 W C Optimum supply line pressure 7 W C NATURAL GAS CONNECTION Your VINTAGE Grill for use with Natural Gas comes equipped with its own regulator which MUST NOT be removed If this r...

Страница 12: ...Page 11 Figure 3 Natural Gas Connection...

Страница 13: ...of liquid soap and water to all connection points 4 It is key to look for bubbles to appear as the appearance of bubbles will indicate a gas leak If a leak is present immediately turn off gas supply...

Страница 14: ...through the notch in the grill rack to the ports of the burner you are trying to light If attempting to light the right burner first ensure that only the right burner control knob is used 2 Position t...

Страница 15: ...r to lighting the burner for adjustment The air shutter adjustment screws are accessible with a screwdriver by removing the burner Loosen the lock screw of the air shutter Refit the burner Make certai...

Страница 16: ...inserted into the holes of the tray Each grill burner has its own igniter The igniter push buttons are located on the sides of the front control panels Figure 5 Low Heat Adjustment COOKING TIPS Grill...

Страница 17: ...ith proper care flare ups should not present a problem with your VINTAGE Grill Minimize flare ups by Properly pre heating the grill Ensuring grill grids are properly installed with the U shape facing...

Страница 18: ...ramic body causing all of the igniters to fail Install the briquette tray and make sure they sit level and do not rock Lastly light all of the burners and check all proper flame characteristics ORIFIC...

Страница 19: ...ch Brite polishing pad Never use steel wool on stainless steel ALWAYS SCRUB IN THE DIRECTION OF THE GRAIN DO NOT SCRUB IN CIRCULAR MOTION ADDITIONAL INFORMATION Always keep the area around the grill f...

Страница 20: ...for LP Check flame characteristics according to the procedure on page 12 and adjust air shutter if needed Check also that there is no pressure being applied to the regulator attached to the back of th...

Страница 21: ...o products purchased in the United States and Canada and is only available to the original owner of the product and is not transferable Product must be purchased in the country where service is reques...

Страница 22: ...ance has been tampered or altered in any way or which in our judgment has been subjected to misuse negligence or accident implied warranty shall not extend beyond the duration of this written warranty...

Страница 23: ......

Страница 24: ......

Отзывы: