pressure 
High superheat  

7)  Low  suction  pressure  and  low  head 

pressure 
High superheat and low subcooling 

8)  Low  suction  pressure  and  low  to  normal 

head pressure 
High superheat and high subcooling 

9)  Low  suction  pressure  and  low  head 

pressure 
Normal  to  high  superheat  and  low 
subcooling 

10) Low  suction  pressure  and  low  head 

pressure 
Low superheat and low subcooling 

11) Low  suction  pressure  and  low  to  normal 

head pressure 
High  superheat  and  normal  to  high 
subcooling 

12) Low  suction  pressure  and  normal  head 

pressure 
High superheat and normal subcooling 

13) Low  suction  pressure  and  high  head 

pressure 
High superheat and high subcooling 

 

14) Low    suction  pressure  and  high  head 

pressure 
High superheat and high subcooling 

15) low  to  normal  suction  pressure  and  high 

head pressure 
Normal  to  high  superheat  and  high 
subcooling 

high evaporator load 
 

7)  Undercharge 
 
 
8)  Liquid  line  restricted  after 

receiver,  solenoid  valve 
restricted 

9)  Suction line restricted 
 
 
 
10) Air  restricted  at  evaporator, 

evaporator iced 
 

11) Evaporator restricted 
 
 
 
12) Expansion valve restricted  

 

 
13) Both 

evaporator 

and 

condenser  restricted;  liquid 
and suction lines connected 
wrong 

14) Liquid  line  restricted  before 

receiver 
 

15) Condenser restricted 
 

 

10. Condensing Unit Troubleshooting 
 

Unit not running 

1)  Incorrect power supply 
2)  Incorrect or loose wirings 
 
3)  Failed components 

 

4)  Low  pressure  switch  shutting  down 

the system 

5)  high pressure switch shutting down 

the system 

1)  Check for proper voltage 
2)  Check 

all 

wirings 

and 

connections 

3)  Check start relay, start capacitor, 

overload protector, compressor. 

4)  Check  for  system  restriction  or 

low refrigerant 

5)  Check for the condenser fan 

Содержание WINE-MATE WM-2500SSV

Страница 1: ...0SSV LA WM 4500SSV WM 4500SSV LA WM 6500SSV WM 6500SSV LA www vinotemp com www vinotemp com Read and save these instructions Read and save these instructions Vinotemp International Corp 732 South Race...

Страница 2: ...1 Important Safety Information...

Страница 3: ...2 Table of Contents Cellar Construction Guide 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 14 Electrical Wirings 26 Warranty 29...

Страница 4: ...temperature surrounding the cellar shall not exceed the temperature of the cellar by more than 25 F No cellar walls shall receive direct sun or strong wind Lighting shall be of low wattage with a tim...

Страница 5: ...SV evaporator units are designed for vertical installation inside a rack or in a wine room corner making them an ideal choice for small and medium wine cellars There are also multiple air inlet and ou...

Страница 6: ...d R19 exterior insulations Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55 F The specifications are listed as follo...

Страница 7: ...ock the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys pr...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...e regulation differential 4 AC anti short cycle delay min 10 hidden Con compress on with probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display...

Страница 10: ...ative humidity Use a separate hygrometer to monitor the humidity 10 How to set alarm call 1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the se...

Страница 11: ...ng Clean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Remo...

Страница 12: ...oling unit turns on at 59 F of air temperature It may be higher than 59 F if it is in anti short cycle or defrost and turns off at 55 F of air temperature The average air temperature is 57 F and then...

Страница 13: ...rt capacitor overload protector compressor c Call service 9 Compressor running but condenser fan not running a Fan blade stuck b Incorrect or loose wirings c Failed motors d Fan cycle control a Check...

Страница 14: ...cessive condensate b High humidity causing excessive condensate c Drain restricted a Check for any air leak b Use drain line c Clean the drip tray and drain line 17 Condensate inside ducts a Drain lin...

Страница 15: ...Installation of the system must be done in accordance with all state and local building and electrical codes The condensing unit and evaporator unit are connected by a liquid line and an insulated suc...

Страница 16: ...18 x 14 x 12 115V 60HZ 1A 115V 60HZ 5A 20A 45 40 WM 2500SSV LA WM 25SFCV 11 3 8 x 11 3 16 x 41 1 2 WM 250SCUR LA 18 x 14 x 12 115V 60HZ 1A 115V 60HZ 6A 20A 45 40 WM 4500SSV WM 45SFCV 11 3 8 x 11 3 16...

Страница 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 25 65SFCV Evaporator Unit...

Страница 18: ...17 Fig 5 WM 250 450SCUR Condensing Unit Fig 6 WM 650SCUR Condensing Unit...

Страница 19: ...y be used to extend the air probe 3 Evaporator Unit Location 1 The WM 25 65SFCV evaporator units should be installed for corner mount with the supply air on the top and return air on the bottom 2 Air...

Страница 20: ...Suction Line Drain Line Recommended Initial Charge WM 2500SSV WM 2500SSV LA 75 FT 1 4 OD 3 8 OD 3 4 MPT R134a 19 OZ WM 4500SSV WM 4500SSV LA 75 FT 1 4 OD 1 2 OD 3 4 MPT R134a 26 OZ WM 6500SSV WM 6500...

Страница 21: ...ack Position Normal operation manifold port is closed Front Position Storage operation liquid or suction line connection is closed Middle Position Installation operation all ports are open NOTE The re...

Страница 22: ...se the manifold high and low pressure valves Turn on the power to start the system 7 Check the following temperatures and pressures 8 Adjusting and Completing the Installation 1 Checking pressure cont...

Страница 23: ...installed at the bottom of the compressor and shall be turned on all the time The heater is self regulated B The condenser fan control The condenser fan control is installed at the high side It close...

Страница 24: ...d until it supplies the required CFM Fig 14 Fan Speed Control 3 The subcooling at the condensing unit shall be around 10 F The charge may be complete when there are no more bubbles forming in the liqu...

Страница 25: ...manifold 9 Pressure Superheat and Subcooling Readings CAUTION To read properly the service valves must be in the middle positions Complaint Possible Causes 1 High suction pressure and low head pressur...

Страница 26: ...g 15 low to normal suction pressure and high head pressure Normal to high superheat and high subcooling high evaporator load 7 Undercharge 8 Liquid line restricted after receiver solenoid valve restri...

Страница 27: ...he field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the condens...

Страница 28: ...27 Fig 17 WM 2500 4500SSV LA Electrical Wiring Diagram Fig 18 WM 6500SSV Electrical Wiring Diagram...

Страница 29: ...28 Fig 19 WM 6500SSV LA Electrical Wiring Diagram...

Страница 30: ...and is in lieu of all other warranties express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever Any...

Страница 31: ...NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly...

Отзывы: