- 22 -
A. P70 Single/Dual Control
B. PS2 Dual Control
Fig. 12 Adjustable Pressure Control
III.
Low ambient condition kit (if applicable)
A.
The crankcase heater
The crankcase heater is installed at the bottom of the compressor and shall be
turned on all the time. The heater is self-regulated.
B.
The condenser fan control
The condenser fan control is installed at the high side. It closes on rise of
pressure. It is necessary to adjust the setting in the field to avoid fan short cycle.
Head pressure setting: Cut in=170 psig; Cut out=110 psig; Differential=60 psig;
Содержание WINE-MATE WM-2500SSV
Страница 2: ...1 Important Safety Information...
Страница 17: ...16 Fig 3 Temperature Controller 4 5 L X 4 5 W X 3 75H Fig 4 WM 25 65SFCV Evaporator Unit...
Страница 18: ...17 Fig 5 WM 250 450SCUR Condensing Unit Fig 6 WM 650SCUR Condensing Unit...
Страница 28: ...27 Fig 17 WM 2500 4500SSV LA Electrical Wiring Diagram Fig 18 WM 6500SSV Electrical Wiring Diagram...
Страница 29: ...28 Fig 19 WM 6500SSV LA Electrical Wiring Diagram...