background image

 

 

- 12 - 

User’s Troubleshooting 

 
This Troubleshooting Chart is not prepared to replace the training required for a 
professional refrigeration service person, not is it comprehensive. 

 

Complaint 

Possible Causes 

Response 

1. Unit not running

 

a.  Power cord not plugged 
b.  No power from supply 
c.  Incorrect or loose wirings 
d.  Low voltage 
e.  Setting  higher  than  ambient 

temperature 

f. 

Waiting for cut-in 

g.  Defrost light blinking 
h.  Compressor light blinking 
i. 

Defective controller 

a.  Check power cord 
b.  Check receptacle and fuses 
c.  Check all wirings and connections 
d.  Contact an authorized electrician 
e.  Lower temperature setting 
 
f. 

Wait 

g.  Unit is under defrost mode 
h.  Unit is under anti-short cycle delay  
i. 

Call service for diagnosis 

2. Unit not starting , but 

temperature rising 
high  

a.  Anti-short cycle  
 

a.  Reset AC 
 

3. Temperature 

fluctuating 

a.  Air probe 
 

a.  When using an air probe, the wine bottle 

temperature  is  mainly  controlled  by  the 
average air temperature. If the set-point 
is  55

°

F  with  the  differential  4F,  the 

cooling  unit  turns  on  at  59

°

F  of  air 

temperature (It may be higher than 59

°

if it is in anti-short cycle or defrost cycle) 
and turns off at 55

°

F of air temperature. 

The  average  air  temperature  is  57

°

F, 

and then the wine temperature is around 
57+/-0.5

°

F.  The  air  is  light  enough  to 

change  so  quickly  that  it  maintains 
relatively constant average temperature 
that 

would 

prevent 

wine 

bottle 

temperature from fluctuating. 

4. Temperature  high, 

unit stopping and 
starting normally 

a.  Temperature setting high 
 

a.  Lower the setting 
 

5. Temperature  high, 

unit stopping and 
starting with short 
running time 

a.  Air probe touching the evaporator 

coil, displaying temperature ok 

b.  Air  probe  in  cold-air  supply, 

displaying temperature ok  

c.  Failed controller and probe 

a.  Move  the  air  probe  away  from  the 

evaporator 

 
b.  Move the air probe away from the cold-

air supply 

c.  Call service for diagnosis 

6. Temperature high or 

not cooling and 
running continually   

a.  Improper cellar insulation & seal 
 
b.  Cellar too large 
c.  Ambient temperature too high 
d.  Exhaust restricted  
 
 
 
e.  Malfunctioning fans 

a.  Check  insulation,  gasket  and  door 

opening 

b.  Check for excessive size   
c.  Check installation location 
d.  Leave minimum 3 feet clearance for the 

hot air exhaust side and leave minimum 
1  foot  clearance  for  the  ambient  air 
intake side  

Содержание WINE-MATE WM-1520SSL

Страница 1: ...1 www winemate com Ceiling Split Cooling System Installation Operation Care Manual WM 1520SSL WM 2520SSL WM 4520SSL WM 6520SSL www vinotemp com...

Страница 2: ...is the personal responsibility of the consumer to have a proper 3 prong wall receptacle installed by a qualified electrician DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE POWER CORD GROUNDING PRONG A sepa...

Страница 3: ...le of Contents Cellar Construction 3 Features Specifications 4 Temperature Humidity 6 Care Guide 10 User Troubleshooting 11 Installer s Instructions 15 Electrical Wirings 25 Customer Support 28 Warran...

Страница 4: ...erature surrounding the enclosure shall not exceed the temperature of the cellar by more than 25 F No cellar wall shall receive direct sun or strong wind Lighting shall be of low wattage with a timer...

Страница 5: ...sing units can be located away from the wine cellars 50 ft so that noise and compressor vibration are isolated SSL evaporator units provide low profile and whisper quiet operation The evaporator units...

Страница 6: ...WM 152SFCL 16 75x14 5x4 75 14 75x14 75 WM 152SCU 18x14x12 1200 150 140 R134a 220V 50Hz 0 2A 220V 50Hz 1 6A 15 30 WM 2520SSL WM 252SFCL 31 75x14 5x4 75 29 75x14 75 WM 252SCU 18x14x12 2100 230 230 R134a...

Страница 7: ...the keypad SET To enter in the programming mode SET To return to the temperature display 2 Lock and unlock the keys To lock the keys press up down keys until POF is displayed to unlock the keys press...

Страница 8: ...nstrument 2 Temperature Setting Set the temperature at 55 F for the optimum aging of wine On initial start up the time required to reach the desired temperature will vary depending on the quantity of...

Страница 9: ...probe faulty min 15 CoF compress off with probe faulty min 30 CF temperature unit F C F Fahrenheit rES display resolution in integer dLy temperature display delay min 1 ot probe calibration 0 LS mini...

Страница 10: ...1 Speech notice will be sent to your phones when the cellar temperature is ALU higher or ALL lower than the set point Set 2 In order to test the call function set parameters Ald 0 and dAO 0 After test...

Страница 11: ...lean the condenser coil regularly Coil may need to be cleaned at least every 6 months Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty 2 Condensate Removing...

Страница 12: ...ure It may be higher than 59 F if it is in anti short cycle or defrost cycle and turns off at 55 F of air temperature The average air temperature is 57 F and then the wine temperature is around 57 0 5...

Страница 13: ...nections b Check start relay start capacitor overload protector compressor c Call service 9 Compressor running but condenser fan not running a Fan blade stuck b Incorrect or loose wirings c Failed mot...

Страница 14: ...ive condensate in wine cellar a Air leak in the wine cellar causing excessive condensate b High humidity causing excessive condensate c Drain restricted a Check for any air leak b Use drain line c Cle...

Страница 15: ...lation is critical Vinotemp can only warrant the quality of the components The installation and proper operation of the system must be warranted by the installer Installation of the system must be don...

Страница 16: ...copper tubing CAUTION Liquid and suction line locations may differ from what are shown here please check on the units for proper installation Fig 3 WM 152 252SFCL Evaporator Unit Fig 4 WM 452 652SFCL...

Страница 17: ...17 Fig 5 WM 152 452SCU Condensing Unit Fig 6 WM 652SCU Condensing Unit...

Страница 18: ...ional wires are needed 18 gauge wires may be used to extend the air probe 3 Evaporator Unit Installation 1 The WM 152 652SFCL evaporator units shall be installed for ceiling mount with the supply air...

Страница 19: ...flooding and shaded from direct sun It shall not be exposed to temperatures higher than 110 F or lower than 50 F 3 Leave minimum 5 ft clearance for the exhaust side and leave minimum 1 foot clearance...

Страница 20: ...e control if applicable for pump down Suction pressure setting Cut out 5 psig Cut in 25 psig Differential 20 psig Head pressure setting Cut out 230 psig Cut in 150 psig Differential 80 psig It may nee...

Страница 21: ...Head pressure setting Cut in 170 psig Cut out 110 psig Differential 60 psig It closes on rise of pressure It may need to adjust the setting in the field to avoid fan short cycle Fig 14 Condenser Fan...

Страница 22: ...he condensing unit is located more than 10 ft above the evaporator unit use U trap to aid oil returning to the compressor 4 Complete pipe brazing check solenoid valve and expansion valve restrictions...

Страница 23: ...ressure setting gives a dew point to maintain the proper humidity for storing wine 4 The temperature split across the evaporator shall be 8 10 F at 55 F wine cellar temperature 5 Again you must verify...

Страница 24: ...l subcooling 13 Low suction pressure and high head pressure High superheat and high subcooling 14 Low suction pressure and high head pressure High superheat and high subcooling 15 low to normal suctio...

Страница 25: ...are the field wirings Use minimum 14 gauge wires for power lines If equipped with low ambient condition kit use low ambient temperature wiring diagrams A safety switch is always recommended for the co...

Страница 26: ...26 Fig 17 WM 6520SSL Electrical Wiring Diagram Fig 18 Low Ambient Temperature WM 1520 4520SSL LA Electrical Wiring Diagram...

Страница 27: ...27 Fig 19 Low Ambient Temperature WM 6520SSL LA Electrical Wiring Diagram...

Страница 28: ...8 Customer Support If you need further assistance please contact us at Vinotemp International 17631 South Susana Road Rancho Dominguez CA 90221 Tel 310 886 3332 Fax 310 886 3310 Email info vinotemp co...

Страница 29: ...s and is in lieu of all other warranties express or implied including any of fitness for a particular purpose In no event shall VINOTEMP be responsible for any consequential damages what is so ever An...

Страница 30: ...ES BASED UPON INCONVENIENCE LOSS OF USE OF THE UNIT LOSS OF TIME OR COMMERCIAL LOSS ANY OUTER DAMAGES WHETHER INCIDENTAL CONSEQUENTIAL OR OTHERWISE THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTH...

Отзывы: