- 4 -
Features and Specifications
•
Wine-Mate split cooling systems WM-1500SS and 1900SS are designed and used to
provide a cold temperature between 50~65
°
F for a properly insulated wine room at a
normal environment.
•
The wine room will maintain humidity of 50~70% RH even when the environment
becomes dry and humid. These temperatures and humilities are optimized for long
term storage of wine.
•
The SS units consist of a condensing unit and an evaporator unit, and they are
connected by a liquid line and an insulated suction line.
•
The condensing units can be located away from the evaporator units and wine cellars
50 ft, which will bring you quiet operation.
•
WM-1500SS evaporator unit can be installed on the ceiling in a wine cellar
and WM-1900SS evaporator unit can be installed on the wall.
The dimensions (in inches) and capacities are specified as follows:
MODE
L
EVAP
UNIT
COND
UNIT
BTU/H,CF
M
(55
°
F/90
°
F)
CAPACITY
(55
°
F/75
°
F)
REFRIGERANT
ELECTRICAL
EVAP UNIT/
COND UNIT
WEIGHT(lb
) EVAP
NIT/
COND
UNIT
WM-
1500SS
WM-
15SFC
WM-
150SCU
1500/180
150 cu ft
R134a
115V-60HZ-
0.4A/115V-
60HZ-3.1A
15/30
WM-
1900SS
WM-
19SFC
WM-
150SCU
1500/180
150 cu ft
R134a
115V-60HZ-
2.2A/115V-
60HZ-5.1A
20/30
NOTE:
CAPACITY IS DETERMINED UNDER THE CELLAR TEMPERATURE, THE
CELLAR AMBIENT TEMPERATURE AND THE CONDENSING UNIT AMBIENT
TEMPERATURE OF 55
°
F, 75
°
F AND 90
°
F, WITH R13 INTERIOR AND R19
EXTERIOR INSULATIONS. ANY HIGHER AMBIENT TEMPERATURES AND
LOWER INSULATIONS WILL CAUSE REDUCING CAPACITY AND THE
CELLAR TEMPERATURE MAY NOT BE MAINTAINED AT 55
°
F.
CAUTION:
LOW AMBIENT TEMPERATURE KIT IS REQUIRED IF THE INSTALLATION
AREA WILL BE BELOW 50
°
F.
CAUTION:
LIQUID AND SUCTION LINES MAY DIFFER FROM WHAT ARE SHOWN
HERE, PLEASE CHECK ON THE UNITS FOR PROPER INSTALLATION.
Parts included: