background image

 

 

STEP

 

8:

 

Attach

 

the

 

pressure

 

regulator

 

to

 

       

the

 

nitrogen/argon

 

cylinder.

 

 

Connect

 

the

 

regulator

 

to

 

the

 

gas

 

cylinder

 

by

 

turning

 

CGA

 

580

 

connection

 

nut

 

counter

clockwise

 

with

 

hand

 

only.

 

The

 

pressure

 

gauge

 

monitors

 

the

 

cylinder

 

inside

 

pressure.

  

STEP

 

7:

 

Now,

 

Attach

 

the

 

other

 

end

 

of

 

each

 

              

gas

 

tube

 

to

 

the

 

manifold.

 

 

Press

 

the

 

latch

 

at

 

the

 

socket

 

and

 

insert

 

the

 

coupling

 

plug

 

into

 

the

 

socket.

 

Содержание VT-WD002-2BTL

Страница 1: ...S T R U C T I O N M A N U A L A P R O U D H E R I T A G E O F E X P E R I E N C E Q U A L I T Y W i n e D i s p e n s i n g P r e s e r v i n g S y s t e m s V T W D 0 0 2 2 B T L 4 B T L 6 B T L 8 B...

Страница 2: ...25 cuft with a chain or strap positioned around the upper third of the cylinder Small cylinders 22 cuft may be put on their side and blocked to prevent from rolling Clear cylinder valve of any dust or...

Страница 3: ...as hose long one with quick disconnect 2 stage pressure regulator Tube clamps Adhesive tapes You will also need a nitrogen argon cylinder not provided HOW TO SET UP YOUR WINE DISPENSING PRESERVING SYS...

Страница 4: ...STEP 3 Now attach the adhesive backed tube clamps to the back of the open cooler STEP 4 Add double sided adhesive tapes to the back of the manifold...

Страница 5: ...STEP 6 Press each gas tube into its clamp STEP 5 Firmly press the manifold to the back of the open cooler and ensure that it is fastened securely...

Страница 6: ...or to the gas cylinder by turning CGA 580 connection nut counter clockwise with hand only The pressure gauge monitors the cylinder inside pressure STEP 7 Now Attach the other end of each gas tube to t...

Страница 7: ...P 9 Insert the gas hose to the connect of the regulator STEP 10 Connect the other end of the hose to the manifold Press the latch and insert the coupling plug into the socket at the side of the manifo...

Страница 8: ...umb and forefinger only to tighten but do not over tighten it Once there are no bubbles forming at the stopper dispenser it indicates the bottle seal is good STEP 11 Turn on the gas Stand to the side...

Страница 9: ...disconnect the other end at the regulator Insert it to the regulator with a new gas cylinder press the coupling plug to let gas escape then insert the coupling plug into the socket at the manifold 2...

Страница 10: ...ations without notice WARNING Please do not place the unit within reach of children For adult use only Contact info vinotemp com with any questions or visit www vinotemp com 17621 S Susana Road Rancho...

Отзывы: