VIMITEX 0200 Series Скачать руководство пользователя страница 8

 305001-002-101-102 G20E

A.4. 

Adaptation

 for Gas Change

All appliances, on delivery, are factory adjusted for use with Propane 37 mbar (G31) or Butane 28-30mbar (G30). 

However, it is necessary to determine whether the low pressure regulator you are using is approved for 37 mbar for 

Propane or 28-30mbar for Butane, respectively.

In case the appliance is to be used with natural gas, or with Propane and Butane at a pressure of 50 mbar, the 

following adjustments must be made after installation, only by a specialist technician, as explained on paragraphs 

4.1, 4.2, 4.3 and 4.4:

 

-

change of injectors

 

-

change of injector of the Oven pilot burner 

 

-

adjustment of the flow of air into the burner

 

-

adjustment of the thermomagnetic gas valve of each burner to the position ‘minimum’ (

, small flame)

After the change of the injector and the air regulation, in order to obtain the gas changes it’s necessary 

to put a mark on the data plate which is placed on the body of the appliance to indicate the new gas 

regulation.

A.4.1 Change of Injectors

The following procedure must be done having the gas supply closed:

To change the injectors on the top burners, you must first remove the grates (2) and unscrew the injector cover (5) 

of the appliance Fig. A. You must remove the burners by unscrewing the two screws under the burner that keep 

them into position. The injectors may then be changed. At the edge of each thermomagnetic gas valve (1) Figure 

C, are the injectors (2). With a number 7 spanner, or a special screwdriver number 7, unscrew the injectors and 

replace them with the injectors you will find in the appliance packaging, either those marked ‘Natural Gas’ or those 

marked ‘Ι3 B/P: 50 mbar’, depending on the gas you are using.

To change the injectors on the oven burner:

 

-

Open the oven door, remove the griddles and the metallic surface situated on the bottom of the oven chamber 

by pulling up using the hole at the front part. 

 

-

By using a screwdriver, loosen up the two screws and the remove the cover of the burner.

 

-

With a number 13 spanner, unscrew the injector (2) Fig C’ and replace it with the injector you will find in the 

appliance packaging, either this marked ‘Natural Gas’ or this marked ‘Ι3 B/P: 50 mbar’, depending on the gas 

you are using.

A.4.2 Change of the injector of the Oven pilot Burner 

The following procedure must be done having the gas supply closed.

After changing the burner injector you have to change also the pilot burner injector which are located next to the 

main burners.

By using a screwdriver, loosen up the two screws and the remove the cover of the burner of the appliance 

according the paragraph A.4.1

With No 11 unscrew the back-end cover of the pilot (12) fig. E and by using a screwdriver replace the injector inside 

the body of the pilot.

Place again the cover with a spanner no 11 and put all the parts on place.

WARNING: It is strictly forbidden to modify the entrance of the combustion air differently from the 

indicated in this Instruction Manual as well as the combustion products evacuation. 

A.4.3 Adjustment of the Flow of Primary Air into the Burner

The following procedure is followed, having the gas supply closed.

 The flow of air into the top burners must 

be adjusted using the ring (3), Figure C, sited on the burner and supported with a screw (4). Loosen the screw (4), 

place the ring in a position such that the distance d=8 mm, for Natural Gas and d=11 mm for the ‘Ι3 B/P: 50 mbar’. 

Tighten the screw (4) again so that the ring (3) is properly secured on the burner. 

Содержание 0200 Series

Страница 1: ...P 0203 K P 202ST P 204ST P 206ST P 751ST P 752ST P 753ST P ST2 P ST4 P ST6 P 204STV P 206STV P 204STVE P 206STVE P 206STVBE P ADJUSTED FOR I3 G 30 G31 28 30 37 mbar ATTENTION USE ONLY IN WELL VENTILAT...

Страница 2: ...2 305001 002 101 102 G20E 1 2 3 8 5 4 6 7 FIG A...

Страница 3: ...305001 002 101 102 G20E 3 FIG D FIG C BURNER 200E FIG C1 FIG C FIG B...

Страница 4: ...I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FI Finland I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FR France I2E G 20 20 25 mbar I3 G 30 G 31 28 30 37 mbar I3B P G 30 G 31 50 mbar DE Germany I2E G 20 20 mba...

Страница 5: ...80 2946 39 84 3140 35 34 2750 ST2 34 5x80x24 200 20 35 12 54 1 26 13 80 1090 12 60 982 13 28 1050 11 78 920 ST4 90x80x24 200 20 35 25 08 2 52 27 60 2180 25 20 1964 26 56 2100 23 56 1840 ST6 134 5x80x...

Страница 6: ...NG THE ABOVE INSTRUCTIONS MIGHT AFFECT THE SECURITY OF THE APPLIANCE NOT FOLLOWING THE ABOVE INSTRUCTIONS CAN CAUSE THE GUARANTEE S DEDUCTION A 2 Safety Rules for Installation This appliance cannot be...

Страница 7: ...whole length from the appliance to the supply tap or to the bottle The connections must be checked for leaks in order to avoid gas escaping with the help of soapy water To do so open the bottle or the...

Страница 8: ...s or those marked 3 B P 50 mbar depending on the gas you are using To change the injectors on the oven burner Open the oven door remove the griddles and the metallic surface situated on the bottom of...

Страница 9: ...BE USED ONLY IN WELL VENTILATED PLACES WARNING IT S STRICTLY FORBIDDEN TO OPEN THE DOOR WHEN THE OVEN IS HOT THERE IS DANGER OF BURN ON YOUR FACE AND HANDS BECAUSE OF THE HOT AIR THAT GOES OUT THE MOM...

Страница 10: ...e procedure Adjust the level of each burner to your preference slowly turning the valve knobs 4 towards the minimum position with the symbol small flame The high or low temperature of the burners is a...

Страница 11: ...t has to be changed when you notice that it doesn t regulated correctly the temperature oven or when you notice a gas leak near the axe or the body of the valve Magnet Unit It is placed inside the the...

Страница 12: ...be replaced in case of malfunction or gas leak Also the good condition of the inside surface of the cooking cabinet of the oven and the griddle gliders must be inspected every day if they are cleaned...

Отзывы: