VIMITEX 0200 Series Скачать руководство пользователя страница 7

 305001-002-101-102 G20E 

7

A.3. Connection

The appliance may be connected in three ways, depending on the type of gas to be used. The connection point (4), 

Figure C, between the appliance and the gas supply is situated at the bottom (or the back) of the appliance.

A rapid- action gas shut -off cock must be fitted upstream of each appliance in an easily accessible position.

Once the appliance has been installed, check for gas leaks at connection points using a soapy water solution.

ATTENTION: 

In case of use for the gas supply connection of the appliance a flexible tube or hose, this shall 

comply with the national requirements and shall be periodically inspected and replaced as necessary.

This appliance must be connected for gas supply only with approved flexible hoses or tubes. Their length should 

not exceed 1.5m and it is forbidden to twist them.

A.3.1 Use of the Appliance with Butane & Propane

Butane:

 Use an approved low pressure regulator 28 – 30mbar

Propane: 

Use an approved low pressure regulator 37mbar

In this case, you may use the connection nozzle (1), Figure B, which accompanies the appliance, to connect it with 

a flexible pipe. 

Screw the nozzle on the bottom (or the back) of the appliance, to the gas connection port (4), with a diameter of 16 

mm (3/8).

This pipe must be approved for this use. 

You must check the date of replacement of the pipe. You must install it in such a way that it is visible along the 

whole length (from the appliance to the supply tap or to the bottle).

The connections must be checked for leaks in order to avoid gas escaping, with the help of soapy water. 

To do so: open the bottle or the supply-tap, to allow the gas to circulate, and ensure that the connection is correct 

by checking for air bubbles in the soapy water spread over the connections.

DANGER:

 THE USE OF A FLAME TO CHECK FOR LEAKS AT CONNECTION POINTS IS STRICTLY 

FORBIDDEN.

A.3.2 Use of the Appliance with Natural Gas

Connection may be made with the help of the nozzle (2), Figure B, when a flexible pipe is to be used, following the 

instructions on the previous paragraph with regard to connection and checking for leaks.

If you wish to make a permanent, fixed connection with a hard pipe screwed into position, it will be necessary to 

use the nozzle (3), Figure B. 

This is the recommended type of connection.

DANGER:

 THE USE OF A FLAME TO CHECK FOR LEAKS AT CONNECTION POINTS IS STRICTLY 

FORBIDDEN. 

A.3.3 Use of the Appliance with Propane & Butane 50 mbar

Butane: 

Use an approved low pressure regulator 50mbar

Propane: 

Use an approved low pressure regulator 50mbar

Connection may be made with the help of the nozzle (1), Figure B, when a flexible pipe is to be used, following the 

instructions on paragraph 3.1, with regard to connection instructions and checking for leaks.

If you wish to make a permanent, fixed connection with a hard pipe screwed into position, it will be necessary to 

use the nozzle (3), Figure B. 

This is the recommended type of connection.

DANGER:

 THE USE OF A FLAME TO CHECK FOR LEAKS AT CONNECTION POINTS IS STRICTLY 

FORBIDDEN.

Содержание 0200 Series

Страница 1: ...P 0203 K P 202ST P 204ST P 206ST P 751ST P 752ST P 753ST P ST2 P ST4 P ST6 P 204STV P 206STV P 204STVE P 206STVE P 206STVBE P ADJUSTED FOR I3 G 30 G31 28 30 37 mbar ATTENTION USE ONLY IN WELL VENTILAT...

Страница 2: ...2 305001 002 101 102 G20E 1 2 3 8 5 4 6 7 FIG A...

Страница 3: ...305001 002 101 102 G20E 3 FIG D FIG C BURNER 200E FIG C1 FIG C FIG B...

Страница 4: ...I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FI Finland I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FR France I2E G 20 20 25 mbar I3 G 30 G 31 28 30 37 mbar I3B P G 30 G 31 50 mbar DE Germany I2E G 20 20 mba...

Страница 5: ...80 2946 39 84 3140 35 34 2750 ST2 34 5x80x24 200 20 35 12 54 1 26 13 80 1090 12 60 982 13 28 1050 11 78 920 ST4 90x80x24 200 20 35 25 08 2 52 27 60 2180 25 20 1964 26 56 2100 23 56 1840 ST6 134 5x80x...

Страница 6: ...NG THE ABOVE INSTRUCTIONS MIGHT AFFECT THE SECURITY OF THE APPLIANCE NOT FOLLOWING THE ABOVE INSTRUCTIONS CAN CAUSE THE GUARANTEE S DEDUCTION A 2 Safety Rules for Installation This appliance cannot be...

Страница 7: ...whole length from the appliance to the supply tap or to the bottle The connections must be checked for leaks in order to avoid gas escaping with the help of soapy water To do so open the bottle or the...

Страница 8: ...s or those marked 3 B P 50 mbar depending on the gas you are using To change the injectors on the oven burner Open the oven door remove the griddles and the metallic surface situated on the bottom of...

Страница 9: ...BE USED ONLY IN WELL VENTILATED PLACES WARNING IT S STRICTLY FORBIDDEN TO OPEN THE DOOR WHEN THE OVEN IS HOT THERE IS DANGER OF BURN ON YOUR FACE AND HANDS BECAUSE OF THE HOT AIR THAT GOES OUT THE MOM...

Страница 10: ...e procedure Adjust the level of each burner to your preference slowly turning the valve knobs 4 towards the minimum position with the symbol small flame The high or low temperature of the burners is a...

Страница 11: ...t has to be changed when you notice that it doesn t regulated correctly the temperature oven or when you notice a gas leak near the axe or the body of the valve Magnet Unit It is placed inside the the...

Страница 12: ...be replaced in case of malfunction or gas leak Also the good condition of the inside surface of the cooking cabinet of the oven and the griddle gliders must be inspected every day if they are cleaned...

Отзывы: