A. INSTALLATION

A.1. Warning

WARNING: THIS APPLIANCE MUST BE INSTALLED BY A SPECIALIST TECHNICIAN ACCORDING TO THE LAWS 

AND REGULATIONS IN FORCE IN THE COUNTRY OF DESTINATION, IN WHICH THE APPLIANCE WILL BE USED
WARNING: THIS APPLIANCE MUST BE INSTALLED ONLY IN WELL AND SUFFICIENT VENTILATED SPACES TO 

PREVENT THE OCCURRENCE OF UNACCEPTABLE CONCENTRATIONS OF SUBSTANCES HARMFUL TO HEALTH

THERE A SERIOUS HEALTH RISK IF THIS APPLIANCE IS USED IN PLACES WITH INADEQUATE VENTILATION. 

FIRE DANGER – THE AREA AROUND THE APPLIANCE MUST BE FREE AND CLEAN FROM FUEL.

For technical support address to the manufacture authorized service.

Ask for the genuine spare parts. 

 

-

The appliance must only be used by trained staff and must be supervised at all times when in use.

 

-

Switch off the appliance if it breaks down or malfunctions.

 

-

Do not use products containing chlorine (bleach, hydrochloric acid etc.) even diluted, to clean steel surfaces.

 

-

Do not leave dirt, fat, food or other products to dry on the appliance.

 

-

This appliance is intended for industrial use only and is specifically designed to cook food. Any other use of the 

appliance is deemed improper.

 

-

Only contact the technical service centre authorized by the manufacturer for repairs and only use original spare 

parts. Failure to comply with the above requirement may jeopardize the safety of the appliance and render the 

guarantee null and void.

 

-

Do not use corrosive substances (i.e. muriatic acid) to clean the floor under the appliance.

 

-

Do not wash the appliance with water jets

NOT FOLLOWING THE ABOVE INSTRUCTIONS MIGHT AFFECT THE SECURITY OF THE APPLIANCE.
NOT FOLLOWING THE ABOVE INSTRUCTIONS CAN CAUSE THE GUARANTEE’S DEDUCTION. 

A.2. Safety Rules for Installation

This appliance cannot be connected to a duct for removing the products of combustion. 

Particular care must be taken with the ventilation systems you use.

The installation, connection and maintenance must be undertaken only by a specialist technician, taking 

into account all the present instructions, as well as the remaining provisions concerning the site of 

installation:

 

-

Examine the packaging before and after the uploading.

 

-

An adequate flow of air in and out of the area is needed

 

-

A window, opening to at least 0.40m² is required

 

-

The installation, use and maintenance of this appliance by children is strictly prohibited. Keep children and 

curious onlookers away when the appliance is in operation.

 

-

The appliance must be installed on a horizontal surface, with a constant heat resistance of at least 90º C. All 

flammable surfaces are prohibited.

 

-

A space of 0.20m must be left around the appliance for ventilation.

 

-

This appliance is not suitable for built –in installation.

 

-

Carefully remove the protective film from the external panels to avoid leaving any trace of glue.

 

-

Use a suitable diluents to remove any glue residue.

 

-

Is strictly forbitten to place objects or food on the top of the appliance. 

 

-

Don’t hang anything over the appliance closer than 1,5m. Leave always the space of 1,5m empty over the 

appliance because the heat from the exhaust duct is very high.

 

-

Do not place anything in front of the appliance at a distance of less than 1.5 meter, because the temperature in 

front of the open door is very high.

 

-

Installation and use of this appliance in basement areas is prohibited.

Содержание 0200 Series

Страница 1: ...P 0203 K P 202ST P 204ST P 206ST P 751ST P 752ST P 753ST P ST2 P ST4 P ST6 P 204STV P 206STV P 204STVE P 206STVE P 206STVBE P ADJUSTED FOR I3 G 30 G31 28 30 37 mbar ATTENTION USE ONLY IN WELL VENTILAT...

Страница 2: ...2 305001 002 101 102 G20E 1 2 3 8 5 4 6 7 FIG A...

Страница 3: ...305001 002 101 102 G20E 3 FIG D FIG C BURNER 200E FIG C1 FIG C FIG B...

Страница 4: ...I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FI Finland I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FR France I2E G 20 20 25 mbar I3 G 30 G 31 28 30 37 mbar I3B P G 30 G 31 50 mbar DE Germany I2E G 20 20 mba...

Страница 5: ...80 2946 39 84 3140 35 34 2750 ST2 34 5x80x24 200 20 35 12 54 1 26 13 80 1090 12 60 982 13 28 1050 11 78 920 ST4 90x80x24 200 20 35 25 08 2 52 27 60 2180 25 20 1964 26 56 2100 23 56 1840 ST6 134 5x80x...

Страница 6: ...NG THE ABOVE INSTRUCTIONS MIGHT AFFECT THE SECURITY OF THE APPLIANCE NOT FOLLOWING THE ABOVE INSTRUCTIONS CAN CAUSE THE GUARANTEE S DEDUCTION A 2 Safety Rules for Installation This appliance cannot be...

Страница 7: ...whole length from the appliance to the supply tap or to the bottle The connections must be checked for leaks in order to avoid gas escaping with the help of soapy water To do so open the bottle or the...

Страница 8: ...s or those marked 3 B P 50 mbar depending on the gas you are using To change the injectors on the oven burner Open the oven door remove the griddles and the metallic surface situated on the bottom of...

Страница 9: ...BE USED ONLY IN WELL VENTILATED PLACES WARNING IT S STRICTLY FORBIDDEN TO OPEN THE DOOR WHEN THE OVEN IS HOT THERE IS DANGER OF BURN ON YOUR FACE AND HANDS BECAUSE OF THE HOT AIR THAT GOES OUT THE MOM...

Страница 10: ...e procedure Adjust the level of each burner to your preference slowly turning the valve knobs 4 towards the minimum position with the symbol small flame The high or low temperature of the burners is a...

Страница 11: ...t has to be changed when you notice that it doesn t regulated correctly the temperature oven or when you notice a gas leak near the axe or the body of the valve Magnet Unit It is placed inside the the...

Страница 12: ...be replaced in case of malfunction or gas leak Also the good condition of the inside surface of the cooking cabinet of the oven and the griddle gliders must be inspected every day if they are cleaned...

Отзывы: