VIMITEX 0200 Series Скачать руководство пользователя страница 5

 305001-002-101-102 G20E 

5

Model

Dimensions

cm

Burner 

Type

Pan 

Diameter mm

G20 20mbar  

2

nd 

fam. H,E,E+ 

G-25 25mbar  

2

nd

 fam. L 

G-30 28-30mbar 

3

rd 

fam. 3+

G-31 37mbar 

3

rd

 fam. 3+

G-30 50mbar 

3

rd 

fam. B/P

G-31 50mbar 

3

rd

 fam. B/P 

-ΣQn-

kW(Hi)

m

3

/h

-ΣQn-

kW(Hi)

m

3

/h

-ΣQn-

kW(Hi)

g/h

-ΣQn-

kW(Hi)

g/h

-ΣQn-

kW(Hi)

g/h

-ΣQn-

kW(Hi)

g/h

0202(P)

38x70x20

200

20-35

12.54

1.26

13.80

1090

12.60

982

13.28

1050

11.78

920

0204(P)

71x70x20

200

20-35

25.08

2.52

27.60

2180

25.20

1964

26.56 2100

23.56 1840

0206(P)

104x70x20

200

20-35

37.62

3.77

41.40

3270

37.80

2946

39.84

3140

35.34 2750

0201K(P)

36,5x40x20

200

20-35

6.27

0.63

6.90

495

6.30

541

6.64

525

5.89

460

0202K(P)

71x40x20

200

20-35

12.54

1.26

13.80

1090

12.60

982

13.28

1050

11.78

920

0203K(P)

104x40x20

200

20-35

18.81

1.89

20.70

1635

18.90

1453

19.92

1570

17.67

1370

202ST(P)

40x70x85/25

200

20-35

12.54

1.26

13.80

1090

12.60

982

13.28

1050

11.78

920

204ST(P)

80x70x85/25

200

20-35

25.08

2.52

27.60

2180

25.20

1964

26.56 2100

23.56 1840

206ST(P) 120x70x85/25

200

20-35

37.62

3.77

41.40

3270

37.80

2946

39.84

3140

35.34 2750

751ST(P)

40x70x430

200

20-35

12.54

1.26

13.80

1090

12.60

982

13.28

1050

11.78

920

752ST(P)

80x70x430

200

20-35

25.08

2.52

27.60

2180

25.20

1964

26.56 2100

23.56 1840

753ST(P)

120x70x430

200

20-35

37.62

3.77

41.40

3270

37.80

2946

39.84

3140

35.34 2750

ST2

34,5x80x24

200

20-35

12.54

1.26

13.80

1090

12.60

982

13.28

1050

11.78

920

ST4

90x80x24

200

20-35

25.08

2.52

27.60

2180

25.20

1964

26.56 2100

23.56 1840

ST6

134,5x80x24

200

20-35

37.62

3.77

41.40

3270

37.80

2946

39.84

3140

35.34 2750

204STV(P)

80x70x98,5

200

20-35

33.35

3.32

35.20

2780 32.80

2556

34.36

2715

30.76

2391

206STV(P) 120x70x98,5

200

20-35

45.89

4.57

49.00

3870 45.40

3538

47.64

3755 42.54

3311

204STVE(P) 80x70x98,5

200E

14-35

32.80

3.29

30.80

2430 30.80

2400

32.60 2572 30.40 2368

206STVE(P) 120x70x98,5

200E

14-35

45.20

4.53

42.40

3345 42.40

3303

45.00 3550 42.00 3272

206STVBE(P) 91x80x96,5

200

20-35

45.89

4.57

49.00

3870 45.40

3538

47.64

3755 42.54

3311

INJECTORS DIAMETER  

Burner Type: 

200 

200E 

OVEN

Gas 2nd fam. H,E,E+ 

G-20  

20 mbar: 

1.90 mm 

1.90 mm 

2.20mm

Gas 3rd fam. 3+ 

G-30/G-31 

28-30/37 mbar: 

1.25 mm 

1.25 mm 

1.45mm

Gas 3rd fam. B/P  

G-30  

50 mbar:  

1.15 mm 

1.15 mm 

1.35mm

Gas 3rd fam. B/P 

G-31  

50 mbar:  

1.15 mm 

1.15 mm 

1.35mm

Qmin

Gas 2nd fam. H,E,E+ 

G-20 

20 mbar: 

1.7 kW 

 2.4 kW 

-

Gas 3rd fam. 3+ 

G-30 

28-30 mbar: 

1.7 kW 

 2.4 kW 

-

Gas 3rd fam. 3+  

G-31  

37 mbar: 

1.7 kW 

 2.4 kW 

-

Gas 3rd fam. B/P 

G-30 

50 mbar: 

1.7 kW 

 2.4 kW 

-

Gas 3rd fam. B/P 

G-31 

50 mbar: 

1.7 kW 

 1.5 kW 

-

Pilot Burner: 0,2 kW
PRIMARY AIR REGULATOR (d)
Natural Gas: 

d= 

 8 mm 

7 mm 

No Change

GLP I3+: 

d= 

11 mm 

6 mm 

No Change

GLP I3B/P: 

d= 

11 mm 

7 mm 

No Change

OVEN PRIMARY AIR REGULATOR: THIS APPLIANCE DOESN’T NEED REGULATING THE PRIMARY AIR AFTER 

CHANGING THE GAS YOU USE.

TYPE: A1

Содержание 0200 Series

Страница 1: ...P 0203 K P 202ST P 204ST P 206ST P 751ST P 752ST P 753ST P ST2 P ST4 P ST6 P 204STV P 206STV P 204STVE P 206STVE P 206STVBE P ADJUSTED FOR I3 G 30 G31 28 30 37 mbar ATTENTION USE ONLY IN WELL VENTILAT...

Страница 2: ...2 305001 002 101 102 G20E 1 2 3 8 5 4 6 7 FIG A...

Страница 3: ...305001 002 101 102 G20E 3 FIG D FIG C BURNER 200E FIG C1 FIG C FIG B...

Страница 4: ...I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FI Finland I2H G 20 20 mbar I3B P G 30 G 31 30 mbar FR France I2E G 20 20 25 mbar I3 G 30 G 31 28 30 37 mbar I3B P G 30 G 31 50 mbar DE Germany I2E G 20 20 mba...

Страница 5: ...80 2946 39 84 3140 35 34 2750 ST2 34 5x80x24 200 20 35 12 54 1 26 13 80 1090 12 60 982 13 28 1050 11 78 920 ST4 90x80x24 200 20 35 25 08 2 52 27 60 2180 25 20 1964 26 56 2100 23 56 1840 ST6 134 5x80x...

Страница 6: ...NG THE ABOVE INSTRUCTIONS MIGHT AFFECT THE SECURITY OF THE APPLIANCE NOT FOLLOWING THE ABOVE INSTRUCTIONS CAN CAUSE THE GUARANTEE S DEDUCTION A 2 Safety Rules for Installation This appliance cannot be...

Страница 7: ...whole length from the appliance to the supply tap or to the bottle The connections must be checked for leaks in order to avoid gas escaping with the help of soapy water To do so open the bottle or the...

Страница 8: ...s or those marked 3 B P 50 mbar depending on the gas you are using To change the injectors on the oven burner Open the oven door remove the griddles and the metallic surface situated on the bottom of...

Страница 9: ...BE USED ONLY IN WELL VENTILATED PLACES WARNING IT S STRICTLY FORBIDDEN TO OPEN THE DOOR WHEN THE OVEN IS HOT THERE IS DANGER OF BURN ON YOUR FACE AND HANDS BECAUSE OF THE HOT AIR THAT GOES OUT THE MOM...

Страница 10: ...e procedure Adjust the level of each burner to your preference slowly turning the valve knobs 4 towards the minimum position with the symbol small flame The high or low temperature of the burners is a...

Страница 11: ...t has to be changed when you notice that it doesn t regulated correctly the temperature oven or when you notice a gas leak near the axe or the body of the valve Magnet Unit It is placed inside the the...

Страница 12: ...be replaced in case of malfunction or gas leak Also the good condition of the inside surface of the cooking cabinet of the oven and the griddle gliders must be inspected every day if they are cleaned...